Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › INVERTER WITH CONVERTER (for 4WD/AWD) › 2020.05–2020.08
RM3620E _51 Engine / Hybrid System _076333 HYBRID / BATTERY CONTROL _0389028 INVERTER WITH CONVERTER(for 4WD/AWD) A

HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER(for 4WD/AWD)  REMOVAL  


CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during inverter with converter assembly removal/installation are shown below.

Necessary Procedures After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedures Effect/Inoperative Function when Necessary Procedure not Performed Link

*: When performing learning using the GTS.

Click here(Click here)

Auxiliary battery terminal is disconnected/reconnected Perform steering sensor zero point calibration Lane control system (Click here)
Parking support brake system*
Pre-collision system
Memorize steering angle neutral point Parking assist monitor system (Click here)
Panoramic view monitor system (Click here)
Reset back door close position Power back door system (Click here)
Power back door initialization Power door lock control system (Click here)
Replacement of inverter with converter assembly Resolver learning
·

DTCs are stored

·

Slight vibration at a vehicle speed of 5 km/h (3 mph) or less

·

Shock or vibration during acceleration


for NICKEL METAL HYDRIDE BATTERY:(Click here)
for LITHIUM-ION BATTERY:(Click here)
Replacement of ECM
for A25A-FXS(w/ Canister Pump Module):

Perform Vehicle Identification Number (VIN) registration


DTC P063051 is output (Click here)
for A25A-FXS(w/o Canister Pump Module):

Perform Vehicle Identification Number (VIN) or frame number registration


(Click here)
for A25A-FXS:

Grill shutter switch specification infomation


Vehicle control history (RoB) [X260E] is stored w/ Canister Pump Module:
(Click here)
w/o Canister Pump Module:
(Click here)
for A25B-FXS:

Perform Vehicle Identification Number (VIN) or frame number registration


DTC P063051 is output (Click here)

CAUTION:
·
A340386

Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.


·
A340358

To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.



NOTICE:

After the power switch is turned off, the navigation system requires approximately a minute to record various types of memory and settings. As a result, after turning the power switch off, wait a minute or more before disconnecting the cable from the negative (-) auxiliary battery terminal.


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.


Hide 3.DRAIN COOLANT (for Inverter)

Hide 12601B 4.REMOVE NO. 1 ENGINE COVER SUB-ASSEMBLY

Hide 17750A 5.REMOVE INLET AIR CLEANER ASSEMBLY

Hide 6.REMOVE AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE

Hide 89661 7.REMOVE ECM

·

for A25A-FXS:

Click here


Hide 82111 8.DISCONNECT ENGINE ROOM MAIN WIRE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A435529

Move the lock lever while pushing the lock on the connector, and disconnect the inverter with converter assembly connector.

NOTICE:
·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Insulate the disconnected terminals with insulating tape.

·

Do not touch the waterproof seal or terminals of the connector.




b.
A435530

Remove the bolt.


c.

Disengage the clamp and disconnect the engine room main wire.


Hide 9.REMOVE CONNECTOR COVER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.
A435531C01
1.958,1.396 2.177,1.583 0.219,0.188 10 true *a 1.708,0.427 1.927,0.594 0.219,0.167 10 true *b
*a Bolt (A)
*b Bolt (B)


Remove the bolt (B).


b.

Using a T25 "TORX" socket wrench, remove the bolt (A) and connector cover assembly from the inverter with converter assembly.

NOTICE:
·

Do not touch the connector cover assembly waterproof seal.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.




Hide 10.CHECK TERMINAL VOLTAGE

CAUTION:

Be sure to wear insulated gloves.


a.
A435532

Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.

Standard Voltage:

0 V


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


HINT:

Use a measuring range of DC 750 V or more on the voltmeter.



Hide 11.TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.
A435533

Temporarily install the connector cover assembly to the inverter with converter assembly.


b.

Using a T25 "TORX" socket wrench, install the bolt.

Torque:
4.5 N*m (46 kgf*cm, 40 in.*lbf)

NOTICE:
·

Do not touch the connector cover assembly waterproof seal.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.




Hide 821H1 12.DISCONNECT FLOOR UNDER WIRE

CAUTION:

Be sure to wear insulated gloves.


a.
A445299C01
2.313,2.844 2.24,3.208 2.24,3.208 1.688,3.208 true 1.49,3.104 1.802,3.302 0.313,0.198 10 false *a
*a Waterproof Seal


Remove the 2 bolts and disconnect the HV floor under wire from the inverter with converter assembly.

NOTICE:
·

Do not damage the terminals, interlock connector or inverter with converter assembly during disconnection.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Although the connector may feel loose, this is not due to a malfunction.




b.
A435576

Remove the 2 nuts and disconnect the HV floor under wire from the inverter with converter assembly.


c.
A443922C01
0.74,0.844 1.01,0.146 1.01,0.146 1.271,0.146 true 1.323,0.052 1.635,0.25 0.313,0.198 10 false *a
*a Waterproof Seal


Remove the bolt and disconnect the HV floor under wire from the inverter with converter assembly.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Insulate the disconnected terminals with insulating tape.




Hide 821H2 13.DISCONNECT HV AIR CONDITIONING WIRE

CAUTION:

Be sure to wear insulated gloves.


a.
A435535C01
0.677,0.635 1,0.333 1,0.333 1.5,0.333 true 1.563,0.26 1.875,0.417 0.313,0.156 10 false *a
*a Waterproof Seal


Remove the 2 bolts.


b.

Disengage the clamp and disconnect the HV air conditioning wire from the inverter with converter assembly.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Insulate the disconnected terminals with insulating tape.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.




Hide 14.REMOVE WIRE HARNESS CLAMP BRACKET

a.
A435536

Remove the nut and wire harness clamp bracket.


Hide 82121 15.DISCONNECT ENGINE WIRE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A435537

Move the lock lever while pushing the lock on the connector, and disconnect the inverter with converter assembly connector.

NOTICE:
·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·

Insulate the disconnected terminals with insulating tape.

·

Do not touch the waterproof seal or terminals of the connector.




b.
A435538N01
1.802,0.375 1.948,0.531 0.146,0.156 10 true A 0.573,0.563 0.719,0.719 0.146,0.156 10 true B 1.625,0.688 1.771,0.844 0.146,0.156 10 true B 1.625,1.333 1.771,1.49 0.146,0.156 10 true B

Disengage the clamp (A) and disconnect the No. 1 fuel vapor feed hose.


c.

Remove the bolt.


d.

Disengage the 3 clamps (B).


e.
A435539N01
2.375,0.385 2.5,0.542 0.125,0.156 10 true B 2.177,2.417 2.302,2.573 0.125,0.156 10 true A 0.74,2.51 0.865,2.667 0.125,0.156 10 true A

Disengage the 2 clamps (A) and disconnect the No. 1 fuel vapor feed hose and No. 2 fuel vapor feed hose.


f.

Remove the bolt.


g.

Disengage the clamp (B).


h.

Disconnect the EGR valve connector.


i.
A431478C01
2.698,1.271 2.896,1.438 0.198,0.167 10 true *b 2.344,1.708 2.552,1.875 0.208,0.167 10 true *c 1.333,0.438 1.542,0.615 0.208,0.177 10 true *a
*a Generator Temperature Sensor Connector
*b Resolver (Transmission Fluid Temperature Sensor) Connector
*c Shift Lever Position Sensor Connector


Disconnect the generator temperature sensor connector, resolver (transmission fluid temperature sensor) connector and shift lever position sensor connector and disengage the clamp.

NOTICE:
C440116

After disconnecting the engine wire, cover the connector of the generator temperature sensor, resolver (transmission fluid temperature sensor) and shift lever position sensor with tape (non-residue type) or equivalent to prevent the entry of foreign matter or water.



j.
A435541

Disengage the 2 clamps.


k.
A435542

Remove the bolt.


l.
A435543

Remove the bolt.


m.
A435544

Disengage the 2 claws and open the engine wire terminal cover.


n.
A435545

Remove the nut.


o.

Disengage the 2 clamps and disconnect the engine wire from the inverter with converter assembly.


Hide 33820B 16.DISCONNECT TRANSMISSION CONTROL CABLE ASSEMBLY

a.
A435546

Remove the nut and disconnect the transmission control cable assembly from the control shaft lever.


b.
A435547

Using a screwdriver, disengage the 4 claws and disconnect the transmission control cable assembly with the clip from the No. 1 transmission control cable bracket.


c.
C377870

Using a screwdriver, disengage the 2 claws and remove the clip from the transmission control cable assembly.


d.
A435548

Remove the 2 bolts and disconnect the transmission control cable assembly from the inverter with converter assembly.


Hide G9225K 17.DISCONNECT NO. 1 INVERTER COOLING HOSE

a.
A435549

Slide the clip and disconnect the No. 1 inverter cooling hose from the inverter with converter assembly.

NOTICE:

Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.



Hide G9228A 18.DISCONNECT NO. 4 INVERTER COOLING HOSE

a.
A435550

Slide the clip and disconnect the No. 4 inverter cooling hose from the inverter with converter assembly.

NOTICE:

Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.



Hide G9221 19.REMOVE INVERTER COVER

CAUTION:

Be sure to wear insulated gloves.


a.
A435551C01
1.469,2.708 1.604,3.104 1.604,3.104 1.823,3.104 true 0.813,2.677 0.813,2.302 0.813,2.302 0.677,2.302 false 2.698,2.656 2.698,2.958 2.698,2.958 2.802,2.958 true 1.26,2.5 1.5,2.167 true 1.885,3.021 2.198,3.177 0.313,0.156 10 false *a 1.563,2.073 1.875,2.229 0.313,0.156 10 false *b 0.552,2.219 0.792,2.375 0.24,0.156 10 false A 2.854,2.885 3.021,3.052 0.167,0.167 10 false A
*a Interlock
*b Waterproof Seal


Remove the 2 bolts and inverter cover from the inverter with converter assembly.

NOTICE:
·

Make sure to pull the inverter cover straight out, as a connector is connected to the inside of the inverter cover.

·

Do not touch the waterproof seal of the inverter cover.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

When removing the inverter cover, do not pull the areas (A) as they may deform.

·

Make sure that the interlock is installed to the inverter cover.

·
A376320C02
2.167,2.115 2.656,1.635 2.656,1.635 2.031,1.24 false 1.031,0.313 1.302,0.313 1.302,0.313 1.823,0.781 true 0.865,0.208 1.177,0.406 0.313,0.198 10 false *a 2.698,1.542 3.01,1.74 0.313,0.198 10 false *1
*1 Inverter Cover
*a Do not remove or excessively tighten the screw


Do not remove or excessively tighten the screw of the inverter cover.

·

Although the inverter cover may feel loose, this is not due to a malfunction.



HINT:
A435552

If necessary, use a screwdriver with its tip wrapped with protective tape as shown in the illustration to remove the inverter cover.



Hide G1148 20.DISCONNECT MOTOR CABLE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Adhere to the following removal procedure. Otherwise, the connector and the inverter with converter assembly may be damaged.


a.
A435553

Using an insulated tool, remove the 6 bolts.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the motor cable.




b.
A435554C01
1.042,0.208 1.24,0.208 1.24,0.208 1.688,0.458 true 0.833,0.115 1.146,0.271 0.313,0.156 10 false *a
*a Waterproof Seal


Remove the 4 bolts and disconnect the motor cable from the inverter with converter assembly.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the motor cable.

·

Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.

·

Insulate the disconnected terminals with insulating tape.

·

After disconnecting the motor cable, wrap it with a plastic bag or equivalent to protect it.

·

Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.

·
A435555

To prevent the wire harness from being caught, make sure to bundle the wire harness using insulating tape or equivalent.




Hide G9200 21.REMOVE INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.

Remove the 5 bolts, 2 nuts and inverter with converter assembly.

A435556

NOTICE:
·

When removing the inverter with converter assembly, be careful not to damage the parts around it.

·

To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.



HINT:

Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter assembly so that coolant does not spill out.



Hide G9214 22.REMOVE NO. 1 INVERTER BRACKET

NOTICE:
A435563C01
0.635,1.052 1.792,1.917 1.792,1.917 2.219,1.073 true 0.135,0.125 0.448,0.281 0.313,0.156 10 false *a 1.76,1.969 2.073,2.125 0.313,0.156 10 false *b
*a Bottom of Inverter with Converter Assembly
*b Support


Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.


a.
A435557C01
2.146,1.844 2.885,1.896 2.885,1.896 2.615,1.688 true 2.958,1.844 3.271,2 0.313,0.156 10 false *a
*a Wooden Block


Set the inverter with converter assembly on wooden blocks.


b.

Remove the 2 bolts and No. 1 inverter bracket from the inverter with converter assembly.


Hide G9215 23.REMOVE NO. 2 INVERTER BRACKET

a.
A435558C01
2.177,1.813 2.833,1.906 2.833,1.906 2.594,1.625 true 2.885,1.854 3.198,2.01 0.313,0.156 10 false *a
*a Wooden Block


Remove the 2 bolts and No. 2 inverter bracket from the inverter with converter assembly.


Hide 24.REMOVE WIRE HARNESS CLAMP BRACKET

a.
A435559

Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.


b.
A435560

Remove the bolt and wire harness clamp bracket from the inverter with converter assembly.


c.
A435561

Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.


d.
A436596

Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.


e.
A436597

Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.