DTC P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) |
DTC P0038 Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2) |
DTC P0057 Oxygen Sensor Heater Control Circuit Low (Bank 2 Sensor 2) |
DTC P0058 Oxygen Sensor Heater Control Circuit High (Bank 2 Sensor 2) |
DTC P0141 Oxygen Sensor Heater Circuit Malfunction (Bank 1 Sensor 2) |
DTC P0161 Oxygen Sensor Heater Circuit Malfunction (Bank 2 Sensor 2) |
DTC P102D O2 Sensor Heater Circuit Performance Bank 1 Sensor 2 Stuck ON |
DTC P105D O2 Sensor Heater Circuit Performance Bank 2 Sensor 2 Stuck ON |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0037 P0057 | Heater current is less than the specified value while the heater is operating. (1 trip detection logic) |
|
| P0038 P0058 | Heater current is less than the specified value while the heater is operating. (1 trip detection logic) |
|
| P0141 P0161 | Cumulative heater resistance correction value exceeds the acceptable threshold. (2 trip detection logic) |
|
| P102D P105D | The heater current is higher than the specified value while the heater is not operating (1 trip detection logic) | ECM |
| Related DTCs | P0037: Heated oxygen sensor (bank 1 sensor 2) heater open/short (Low electrical current) P0038: Heated oxygen sensor (bank 1 sensor 2) heater open/short (High electrical current) P0057: Heated oxygen sensor (bank 2 sensor 2) heater open/short (Low electrical current) P0058: Heated oxygen sensor (bank 2 sensor 2) heater open/short (High electrical current) P0141: Heated oxygen sensor (bank 1 sensor 2) heater performance P0161: Heated oxygen sensor (bank 2 sensor 2) heater performance P102D: Heated oxygen sensor (bank 1 Sensor 2)heater stuck ON P105D: Heated oxygen sensor (bank 2 Sensor 2) heater stuck ON |
| Required Sensors/ Components (Main) | Heated oxygen sensor (bank 1, 2 sensor 2) heater |
| Required Sensors/ Components (Related) | - |
| Frequency of Operation | Continuous: P0037, P0038, P0057, P0058, P102D, P105D Once per driving cycle: P0141, P0161 |
| Duration | 2.064 seconds: P0038, P0058 0.5 seconds: P0037, P0057, P102D, P105D 10 seconds: P0141 and P0161 |
| MIL Operation | Immediate: P0037, P0038, P0057, P0058, P102D, P105D 2 driving cycles: P0141, P0161 |
| Sequence of Operation | None |
| Monitor runs whenever the following DTCs are not stored | None |
| All of the following conditions are met | - |
| Engine | Running |
| Starter | Off |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater on | 10 seconds or more |
| Learned heater off current operation | Completed |
| Learned heater off current operation | Succeeded |
| Heated oxygen sensor heater high current fail (P0038, P0058) | Not detected |
| Heater on current - Learned heater off current | 0.15 A or less |
| Heater output | On |
| All of the following conditions are met | - |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | Off |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater on | 10 seconds or more |
| Learned heater off current operation | Completed |
| Heater off current | Higher than 3.5 A |
| Hybrid IC high current limiter monitor input | Fail |
| Heated oxygen sensor heater high current fail (P0038 P0058) | Not detected |
| All of the following conditions are met | - |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | Off |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater on | 10 seconds or more |
| Learned heater off current operation | Completed |
| All of the following conditions are met | - |
| Heated oxygen sensor heater circuit fail (P0037, P0038, P0057, P0058, P102D and P105D) | Not detected |
| Battery voltage | 10.5 V or higher |
| Fuel cut | Off |
| Time after fuel cut on to off | 30 seconds or more |
| Accumulated heater on time | 100 seconds or more |
| Learned heater off current operation | Completed |
| Duration that rear heated oxygen sensor impedance is less than 15 kΩ | 2 seconds or more |
| All of the following conditions are met | - |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | Off |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater on | 10 seconds or more |
| Learned heater off current operation | Completed |
| Oxygen sensor heater low current fail (P0037, P0057) | Not detected |
| Oxygen sensor heater high current fail (P0038, P0058) | Not detected |
| Heater current - Learned heater off current | 0.3 A or less |
| Heater on current | 1 A or less |
| Both of the following conditions are met | - |
| Hybrid IC high current limiter monitor input | Fail |
| Heater output | On |
| Heater resistance | Varies with sensor element temperature (Example: Higher than 23 Ω) |
| Heater on current | Higher than 1 A |
| Heated Oxygen sensor heater current | 0.4 to 1 A (when engine idles, heated oxygen sensor warmed up and battery voltage 11 to 14 V) |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
Inspect the heated oxygen sensor (Click here).
|
| ||||
| OK | |
| 2.CHECK TERMINAL VOLTAGE (POWER SOURCE OF HEATED OXYGEN SENSOR) |
![]() |
Disconnect the heated oxygen sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H3-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| H4-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Heated Oxygen Sensor) |
| *b | Bank 1 |
| *c | Bank 2 |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM) |
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| H3-1 (HT1B) - E12-12 (HT1B) | Always | Below 1 Ω |
| H4-1 (HT2B) - E12-13 (HT2B) | Always | Below 1 Ω |
| H3-1 (HT1B) or E12-12 (HT1B) - Body ground | Always | 10 kΩ or higher |
| H4-1 (HT2B) or E12-13 (HT2B) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.CHECK WHETHER DTC OUTPUT RECURS (DTC P0037, P0038, P0057, P0058, P0141, P0161, P102D OR P105D) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Clear DTCs (Click here).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON.
Turn the Techstream on.
Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read pending DTCs.
| Result | Proceed to |
| DTC is not output | A |
| DTC P0037, P0038, P0057, P0058, P0141, P0161, P102D or P105D is output | B |
|
| ||||
| A | ||
| ||
| 5.INSPECT EFI RELAY |
Inspect the EFI relay (Click here).
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - EFI RELAY) |
Disconnect the heated oxygen sensor connector.
Remove the EFI relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| H3-2 (+B) - 3 (EFI relay holder) | Always | Below 1 Ω |
| H4-2 (+B) - 3 (EFI relay holder) | Always | Below 1 Ω |
| H3-2 (+B) or 3 (EFI relay holder) - Body ground | Always | 10 kΩ or higher |
| H4-2 (+B) or 3 (EFI relay holder) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||