DESCRIPTION

This DTC is stored if refrigerant pressure on the high pressure side is extremely low (196 kPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3140 kPa (32.0 kgf/cm2, 455 psi) or more). The air conditioner pressure sensor, which is installed on the pipe on the high pressure side to detect refrigerant pressure, sends a refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts this signal to a pressure value according to the sensor characteristics and uses it to control the compressor.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1423 Pressure Sensor Circuit
·

Open or short in air conditioner pressure sensor circuit

·

Refrigerant pressure on high pressure side is extremely low (196 kPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3140 kPa (32.0 kgf/cm2, 455 psi) or more)


·

Air conditioner pressure sensor

·

Harness or connector between air conditioner pressure sensor and air conditioning amplifier assembly

·

Air conditioning amplifier assembly

·

Cooler expansion valve (blocked, stuck)

·

Condenser assembly (blocked, deterioration of cooling capacity due to dirt)

·

Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)

·

Cooling fan system (condenser assembly cannot be cooled down)

·

A/C system (leaks, blocked)


-

WIRING DIAGRAM

E229252E68
2.229,1.969 2.323,2.146 0.094,0.177 10 false 1 2.229,1.021 2.323,1.198 0.094,0.177 10 false 2 4.854,1.021 4.948,1.198 0.094,0.177 10 false 9 4.771,1.969 4.969,2.146 0.198,0.177 10 false 34 1.885,1.115 2.229,1.417 0.344,0.302 10 false PR 1.031,3.906 3.115,4.24 2.083,0.333 10 false Air Conditioner Pressure Sensor 1.021,3.75 1.563,4.073 0.542,0.323 10 false A43 5.083,2.063 5.427,2.24 0.344,0.177 10 false SG-2 5.083,3.021 5.427,3.198 0.344,0.177 10 false S5-3 4.646,3.729 4.938,3.906 0.292,0.177 10 false F3 4.646,3.885 6.198,4.292 1.552,0.406 10 false Air Conditioning Amplifier Assembly 2.229,2.927 2.323,3.104 0.094,0.177 10 false 3 2,2.052 2.094,2.229 0.094,0.177 10 false - 2,3.021 2.104,3.198 0.104,0.177 10 false + 4.771,2.927 4.979,3.094 0.208,0.167 10 false 30 5.063,1.135 5.531,1.396 0.469,0.26 10 false PSW

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
a.

Disconnect the A43 air conditioner pressure sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A43-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)

NG

18.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)
a.

Disconnect the A43 air conditioner pressure sensor connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A43-1 (-) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

3.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

17.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
3.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Reconnect the A43 air conditioner pressure sensor connector.


b.
E182281C36
1.104,0.083 1.594,0.375 0.49,0.292 1.479,1.021 1.958,1.854 true 1.875,1.885 2.302,2.104 0.427,0.219 10 false PSW 1.271,0.156 1.573,0.333 0.302,0.177 10 false F3 0.104,0.01 0.323,0.188 0.219,0.177 10 false *a
*a Component with harness connected (Air Conditioning Amplifier Assembly)


Remove the air conditioning amplifier assembly with connectors still connected.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
F3-9 (PSW) - Body ground Ignition switch ON
A/C switch off
0.74 to 4.62 V


HINT:

If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier assembly, air conditioner pressure sensor, or wire harness. It is also possible that the amount of refrigerant may not be appropriate.



Result:
Proceed to
OK
NG



OK

4.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

11.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
4.CHECK AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Measure the voltage when the following conditions are satisfied.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)>DTC CHECK / CLEAR

NOTICE:

If the battery is disconnected, the past DTCs will be cleared.


Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch On
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)
Engine Speed 2000 rpm

NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.8 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


i.
E182281C36
1.104,0.083 1.594,0.375 0.49,0.292 1.479,1.021 1.958,1.854 true 1.875,1.885 2.302,2.104 0.427,0.219 10 false PSW 1.271,0.156 1.573,0.333 0.302,0.177 10 false F3 0.104,0.01 0.323,0.188 0.219,0.177 10 false *a
*a Component with harness connected
(Air Conditioning Amplifier Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
F3-9 (PSW) - Body ground Conditions in "Measurement Condition" chart above are met 0.74 to 4.62 V


Result:
Result Proceed to
OK (When troubleshooting according to the DTC) A
OK (When troubleshooting according to Problem Symptoms Table) B
NG C





A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

C

5.CHECK COOLING FAN SYSTEM
5.CHECK COOLING FAN SYSTEM
a.

Check that the cooling fan(s) operates normally.

Click hereEngine / Hybrid System>1NR-FE COOLING>COOLING FAN SYSTEM>ON-VEHICLE INSPECTION


Result:
Proceed to
OK
NG



OK

6.CHARGE SYSTEM WITH REFRIGERANT

NG

6.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the A/C system.


c.

Add an appropriate amount of refrigerant.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTCs.



Result:
Proceed to
NEXT



NEXT

7.RECHECK FOR DTC
7.RECHECK FOR DTC
a.

Recheck for the DTCs when the following conditions are satisfied.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)>DTC CHECK / CLEAR

NOTICE:

If the battery is disconnected, the past DTCs will be cleared.


Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch On
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)
Engine Speed 1500 rpm

Body Electrical > Air Conditioner > Trouble Codes
50001 121
NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTCs. If the DTC is not output after this work, it indicates that the cooler dryer in the condenser is not able to absorb moisture in the refrigerant cycle. It is necessary to replace the cooler dryer in order to complete the repair.



Result:
Result Proceed to
DTC B1423 is output A
DTC B1423 is not output B




A

8.REPLACE COOLER EXPANSION VALVE

B

REPLACE COOLER CONDENSER ASSEMBLY

8.REPLACE COOLER EXPANSION VALVE
a.

Replace the cooler expansion valve.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>COOLER EXPANSION VALVE>REMOVAL

HINT:

Replace the cooler expansion valve with a new one because the expansion valve is either stuck or clogged.



Result:
Proceed to
NEXT



NEXT

9.CHARGE SYSTEM WITH REFRIGERANT
9.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the A/C system.


c.

Add an appropriate amount of refrigerant.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTCs.



Result:
Proceed to
NEXT



NEXT

10.RECHECK FOR DTC
10.RECHECK FOR DTC
a.

Recheck for the DTC when the following conditions are satisfied.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)>DTC CHECK / CLEAR

NOTICE:

If the battery is disconnected, the past DTCs will be cleared.


Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch On
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)
Engine Speed 1500 rpm

Body Electrical > Air Conditioner > Trouble Codes
50001 121
NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant pressure is not normal after replacing the cooler expansion valve with a new or known good one, the condenser or pipes may be clogged due to dirt, dust or other foreign matter. In this case, clean or replace the condenser or pipes.



Result:
Result Proceed to
DTC B1423 is not output A
DTC B1423 is output B




A

END

B

CLEAN OR REPLACE COOLER CONDENSER ASSEMBLY OR PIPE

11.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the A43 air conditioner pressure sensor connector.


b.

Disconnect the F3 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A43-2 (PR) - F3-9 (PSW) Always Below 1 Ω
A43-2 (PR) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

12.CHECK FOR A/C SYSTEM LEAK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

12.CHECK FOR A/C SYSTEM LEAK
a.

Install a manifold gauge set.


b.

Recover the refrigerant from the A/C system using a refrigerant recovery unit.


c.

Evacuate the A/C system and check that vacuum can be maintained.

OK:

Vacuum can be maintained in the A/C system.


HINT:

If vacuum cannot be maintained in the A/C system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the A/C system.



Result:
Proceed to
OK
NG



OK

13.CHARGE SYSTEM WITH REFRIGERANT

NG

16.REPAIR A/C SYSTEM LEAK
13.CHARGE SYSTEM WITH REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the A/C system.


c.

Add an appropriate amount of refrigerant.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the cooler expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTCs.



Result:
Proceed to
NEXT



NEXT

14.RECHECK FOR DTC
14.RECHECK FOR DTC
a.

Recheck for the DTCs when the following conditions are satisfied.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)>DTC CHECK / CLEAR

NOTICE:

If the battery is disconnected, the past DTCs will be cleared.


Item Condition
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch On
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)
Engine Speed 1500 rpm

Body Electrical > Air Conditioner > Trouble Codes
50001 121
NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the A/C operates for a while.


HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


Result:
Result Proceed to
DTC B1423 is output A
DTC B1423 is not output B


NOTICE:

If the DTC was set due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks from as necessary.




A

15.INSPECT AIR CONDITIONER PRESSURE SENSOR

B

END

15.INSPECT AIR CONDITIONER PRESSURE SENSOR

Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

16.REPAIR A/C SYSTEM LEAK
a.

Identify the area where refrigerant leaks from.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT


b.

Repair the identified area of the A/C system.


c.

Evacuate the A/C system.


Result:
Proceed to
NEXT



NEXT

17.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the A43 air conditioner pressure sensor connector.


b.

Disconnect the F3 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A43-1 (-) - F3-34 (SG-2) Always Below 1 Ω
A43-1 (-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

18.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the A43 air conditioner pressure sensor connector.


b.

Disconnect the F3 air conditioning amplifier assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A43-3 (+) - F3-30 (S5-3) Always Below 1 Ω
A43-3 (+) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG