| DTC |
DTC name |
DTC detecting condition |
Warning light |
C1372
|
Invalid Data Received From ENG A-STOP Control Module to ABS / ESP® Control Module |
Communication error with ESP® control module. |
Blinks |
C1373
|
Invalid Data Received From ENG A-STOP Control Module to ABS / ESP® Control Module |
Communication error with ESP® control module. |
Blinks |
P0555
|
Brake Booster Pressure Sensor Circuit |
ESP® control module detected brake booster pressure sensor malfunction. |
Blinks |
P0602
|
Control Module Programming Error |
ENG A-STOP control module internal failure (programming error). |
Off |
P081D
|
Neutral Input Circuit |
Measured voltage of neutral position switch signal circuit is not as specified for specified time continuously. |
Blinks |
P083F
|
Clutch Pedal Switch “A” / “B” Correlation |
This DTC is detected if all of the following conditions are met.
•ON signal of CPP No.1 switch is input for specified time continuously. •OFF signal of CPP No.2 switch is input for specified time continuously.
|
Blinks |
P1300
|
ENG A-STOP Control Module Performance |
ENG A-STOP control module internal failure (data programming error). |
Off |
P1302
|
ENG A-STOP Control Module Power Input Signal Low |
Main power supply voltage is lower than specified voltage for specified time continuously. |
Blinks |
P1303
|
ENG A-STOP Control Module Power Input Signal High |
Main power supply voltage is higher than specified voltage for specified time continuously. |
Blinks |
P1305
|
Internal Control Module Memory Check Sum Error |
ENG A-STOP control module internal failure (check sum error). |
Off |
P1311
|
ENG A-STOP Starter Relay Circuit Low |
Measured voltage of ST2 relay drive circuit is not as specified for specified time continuously. |
Blinks |
P1312
|
ENG A-STOP Starter Relay Circuit High |
Measured voltage of ST2 relay drive circuit is not as specified for specified time continuously. |
Blinks |
P1313
|
ENG A-STOP Starter Performance |
Starting motor driving counter exceeds 180,000. |
Blinks |
P1314
|
ENG A-STOP Starter Active Counter Not Set |
Number of times of starting motor operation is not registered in ENG A-STOP control module. |
Blinks |
P1321
|
ENG A-STOP Battery Current Sensor “A” Circuit Low |
Measured voltage of electric load current sensor circuit is lower than 0.2 V for specified time continuously. |
Blinks |
P1322
|
ENG A-STOP Battery Current Sensor “A” Circuit High |
Measured voltage of electric load current sensor circuit is higher than 4.8 V for specified time continuously. |
Blinks |
P1326
|
ENG A-STOP Battery Temperature Sensor Circuit Low |
Measured voltage of battery temperature sensor circuit is lower than 0.3 V (M16A model / K14C model) or 0.2 V (D16AA model) for specified time continuously. |
Blinks |
P1327
|
ENG A-STOP Battery Temperature Sensor Circuit High |
Measured voltage of battery temperature sensor circuit is higher than 4.7 V for specified time continuously. |
Blinks |
P1335
|
ENG A-STOP DC-DC Converter “B” Performance |
DC/DC converter input signal voltage does not change from the upper limit for more than specified time. |
Blinks |
P1336
|
ENG A-STOP DC-DC Converter “B” Enable Circuit / Open |
Monitored status of DC/DC converter output signal circuit is higher than specified value for specified time. |
Blinks |
P1337
|
ENG A-STOP DC-DC Converter “B” Enable Circuit Low |
Monitored status of DC/DC converter output signal circuit is less than specified value for specified time. |
Blinks |
P1338
|
ENG A-STOP DC-DC Converter “B” Enable Circuit High |
Monitored status of DC/DC converter output signal circuit is higher than specified value for specified time. |
Blinks |
P133A
|
Internal DC/DC Converter Voltage Low |
Output voltage of DC/DC converter integrated in ENG A-STOP control module is lower than specified value for specified time continuously. |
Blinks |
P133B
|
Internal DC/DC Converter Voltage High |
Output voltage of DC/DC converter integrated in ENG A-STOP control module is higher than specified value for specified time continuously. |
Blinks |
P1340
|
ENG A-STOP ECM Sequence Counter Incorrect |
Communication error with ECM. |
Blinks |
P1341
|
Invalid Data Received From ENG A-STOP Control Module to ECM |
Communication error with ECM. |
Blinks |
P1355
|
ENG A-STOP DC-DC Converter “B” Over Temperature Short Time |
DC/DC converter overheat signal is received. |
Off |
P1356
|
ENG A-STOP DC-DC Converter “B” Over Temperature |
DC/DC converter overheat signal is received for more than specified time. |
Blinks |
P1357
|
ENG A-STOP DC-DC Converter “B” Internal Electronic Failure |
While cranking, invalid DC/DC converter input signal is received. |
Blinks |
P1358
|
ENG A-STOP DC-DC Converter “B” Output Circuit Short to Ground |
While ignition is “OFF”, DC/DC converter input signal voltage does not change from the lower limit for more than specified time. |
Blinks |
P1360
|
ENG A-STOP Battery Performance |
7 V or lower battery voltage is detected specified number of times consecutively. |
Blinks |
P254F
|
Engine Hood Switch Circuit |
ON/OFF signals from hood latch switch 1 and hood latch switch 2 are the same for specified time continuously. |
Blinks |
U0073
|
Control Module Communication Bus Off |
ENG A-STOP control module fails to transmit and receive data via CAN for specified time continuously. |
Blinks |
U0100
|
Lost Communication With ECM |
Error in receiving data from ECM via CAN for specified time continuously. |
Blinks |
U0101
|
Lost Communication With TCM |
Error in receiving data from TCM via CAN for specified time continuously. |
Blinks |
U0121
|
Lost Communication With ABS / ESP® Control Module |
Error in receiving data from ESP® control module via CAN for specified time continuously. |
Blinks |
U0140
|
Lost Communication With Body Control Module |
Error in receiving data from BCM via CAN for specified time continuously. |
Blinks |
U0141
|
Lost Communication With Keyless Start Control Module |
Error in receiving data from keyless start control module via CAN for specified time continuously. |
Blinks |
U0155
|
Lost Communication With Instrument Panel Cluster (IPC) Control Module |
Receiving error of the data from combination meter via CAN for specified time continuously. |
Blinks |