| B1411
|
Room Temperature Sensor Circuit
|
Any of the following conditions is met:
·
Open in cooler thermistor (room temperature sensor) circuit
·
Short in cooler thermistor (room temperature sensor) circuit
|
|
| B1412
|
Ambient Temperature Sensor Circuit
|
Any of the following conditions is met:
·
Open in ambient temperature sensor circuit
·
Short in ambient temperature sensor circuit
|
|
| B1413
|
Evaporator Temperature Sensor Circuit
|
Any of the following conditions is met:
·
Open in No. 1 cooler thermistor (evaporator temperature sensor) circuit
·
Short in No. 1 cooler thermistor (evaporator temperature sensor) circuit
|
|
| B1423
|
Pressure Sensor Circuit
|
Any of the following conditions is met:
·
Open in air conditioner pressure sensor circuit
·
Short in air conditioner pressure sensor circuit
·
Refrigerant pressure on high pressure side is extremely low (0.195 MPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2.812 MPaG (28.7 kgf/cm2, 408 psi) or more)
|
|
| B1441
|
Air Mix Damper Control Servo Motor Circuit (Passenger Side)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly
|
|
| B1442
|
Air Inlet Damper Control Servo Motor Circuit
|
Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly
|
|
| B1443
|
Air Outlet Damper Control Servo Motor Circuit
|
Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly
|
|
| B1446
|
Air Mix Damper Control Servo Motor Circuit (Driver Side)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly
|
|
| B1471
|
A/C Inverter High Voltage Power Resource System Malfunction
|
Any of the following conditions is met:
·
Open in A/C inverter high voltage power source system
·
Short in A/C inverter high voltage power resource system
·
Boost inverter malfunctioning
|
|
| B1472
|
A/C Inverter High Voltage Output System Malfunction
|
Any of the following conditions is met:
·
Open in A/C inverter high voltage output circuit
·
Short in A/C inverter high voltage output circuit
|
|
| B1473
|
A/C Inverter Start-up Signal System Malfunction
|
Any of the following conditions is met:
·
Open in A/C inverter start-up signal circuit
·
Short in A/C inverter start-up signal circuit
|
|
| B1474
|
A/C Inverter Malfunction
|
A/C inverter malfunction
|
|
| B1475
|
A/C Inverter Cooling / Heating System Malfunction
|
Any of the following conditions is met:
·
A/C inverter temperature outside specified range (temperature too high)
·
There is an open to ground in temperature sensor circuit
·
There is a Short to ground in temperature sensor circuit
|
|
| B1476
|
A/C Inverter Load System Malfunction
|
Any of the following conditions is met:
·
Motor rotation load while the compressor is operating is too large
·
Motor rotation load while the compressor is operating is too small
|
|
| B1477
|
A/C Inverter Low Voltage Power Resource System Malfunction
|
Any of the following conditions is met:
·
An open to ground in the inverter control power voltage circuit
·
A short to ground in the inverter control power voltage circuit
|
|
| B1497
|
Communication Malfunction (Bus Ic)
|
Any of the following conditions is met:
·
Error in communication line
·
Open in communication line
|
|
| B1498
|
Communication Malfunction (A/C Inverter Local)
|
Any of the following conditions is met:
·
Error in communication line between the hybrid vehicle control ECU and compressor with motor assembly
·
Open in communication line between the hybrid vehicle control ECU and compressor with motor assembly
·
High-voltage power source shut off
|
|
| B14B2
|
Lost Communication with Front Panel LIN
|
Lost communication with air conditioning control assembly
|
|
| B14B8
|
Refrigerant Shortage
|
When following condition is detected in refrigerant shortage check in normal operation:
Amount of refrigerant is insufficient
|
|
| B14B9
|
Open in Ion Generator Circuit
|
Open in ion generator sub-assembly circuit
|
|
| P1C7C49
|
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
|
High voltage system insulation malfunction
|
|
| U0131
|
Lost Communication with Electric Power Steering ECU
|
No communication with power steering ECU assembly
|
|
| U0142
|
Lost Communication with Main Body ECU
|
No communication with main body ECU (multiplex network body ECU)
|
|
| U0155
|
Lost Communication with Combination Meter
|
No communication with combination meter assembly
|
|
| U0293
|
Lost Communication with HV ECU
|
No communication with hybrid vehicle control ECU
|
|