The ECM constantly generates 5 V power from the battery voltage supplied to the +B (BATT) terminal to operate the microprocessor. The ECM also provides this power to the sensors through the VC output circuit. When the VC circuit is short-circuited, the microprocessor in the ECM and sensors that are supplied power through the VC circuit are inactivated because the power is not supplied from the VC circuit. Under this condition, the system does not start up and the MIL does not illuminate even if the system malfunctions.
HINT:
Under normal conditions, the MIL is illuminated for several seconds when the ignition switch is first turned ON. The MIL goes off when the engine is started.
WIRING DIAGRAM
INSPECTION PROCEDURE
1. CHECK MIL
Check that the Malfunction Indicator Lamp (MIL) lights up when turning the ignition switch ON.
OK:
MIL lights up
OK
SYSTEM OK
NG
2. CHECK COMMUNICATION BETWEEN INTELLIGENT TESTER AND ECM
Connect an intelligent tester to the DLC3.
Turn the ignition switch ON and turn the tester ON.
Check the communication between an intelligent tester and ECM.