ECM Power Source Circuit
Circuit diagnosis · Vehicles built from Oct 2014
DESCRIPTION
When the ignition switch is turned to ON, the battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil of the No. 1 integration relay (EFI MAIN relay), closing the contacts and supplying power to terminals +B of the ECM.WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| 1. CHECK NO. 1 INTEGRATION RELAY (POWER SOURCE) |
![]() ![]() |
Remove the No. 1 integration relay from the No. 1 engine room relay block and junction block.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
10C-1 - Body ground
Always
11 to 14 V
Text in Illustration *a
Front view of wire harness connector
(to No. 1 Integration Relay)
|
|
||||
| OK | |
| 2. INSPECT NO. 1 INTEGRATION RELAY (EFI MAIN) |
Inspect the No. 1 integration relay (EFI MAIN) (Click here).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - ECM, BODY GROUND) |
Remove the No. 1 integration relay from the No. 1 engine room relay block and junction block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
B74-5 (MREL) - 10B-2
Always
Below 1 Ω
B74-1 (+B) - 10B-4
Always
Below 1 Ω
10B-3 - Body ground
Always
Below 1 Ω
B74-5 (MREL) or 10B-2 - Body ground
Always
10 kΩ or higher
B74-1 (+B) or 10B-4 - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
D100-109 (E1) - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 5. INSPECT ECM (IGSW VOLTAGE) |
![]() ![]() |
Disconnect the ECM connectors.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
B74-25 (IGSW) - Body ground
Ignition switch ON
11 to 14 V
Text in Illustration *a
Front view of wire harness connector
(to ECM)
|
|
||||
| OK | ||
| ||
| 6. CHECK NO. 2 INTEGRATION RELAY (POWER SOURCE) |
![]() ![]() |
Remove the No. 2 integration relay from the instrument panel relay block.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
12A-1 - Body ground
Always
11 to 14 V
Text in Illustration *a
Front view of wire harness connector
(to No. 2 Integration Relay)
|
|
||||
| OK | |
| 7. INSPECT NO. 2 INTEGRATION RELAY (IG2) |
Inspect the No. 2 integration relay (IG2) (Click here).
|
|
||||
| OK | |
| 8. CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - IGNITION SWITCH, ECM, BODY GROUND) |
Disconnect the ECM connector.
Disconnect the ignition switch connector.
Remove the No. 2 integration relay from the instrument panel relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
12D-2 - H25-6 (IG2)
Always
Below 1 Ω
12B-7 - B74-25 (IGSW)
Always
Below 1 Ω
12E-4 - Body ground
Always
Below 1 Ω
12D-2 or H25-6 (IG2) - Body ground
Always
10 kΩ or higher
12B-7 or B74-25 (IGSW) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 9. INSPECT IGNITION SWITCH |
Inspect the ignition switch (Click here).
|
|
||||
| OK | ||
| ||