2011-2013 Land Cruiser · Service Manual Engine / Hybrid / EV System

Cranking Holding Function Circuit

Circuit diagnosis · Vehicles built Sep 2011 – Dec 2011

DESCRIPTION

The cranking holding control system provides current to the starter when the ECM detects the engine switch start signal (STSW). When the ECM performs a firing judgment, the system cuts current to the starter. When an ECM receives the STSW signal, it turns on the ACC Cut relay, which prevents flickering of the combination meter, clock, audio system, etc. Also, the ECM sends a signal to the STAR terminal of the ECM. Then the STAR output signal travels through the Park/Neutral Position (PNP) switch to the STARTER relay, causing the starter to activate.
When the engine is cranking, the starter operation signal is sent to the STA terminal of the ECM.
A103821E42

WIRING DIAGRAM

A180644E03
A180644E04

INSPECTION PROCEDURE


1. CHECK CRANKING
  1. Check the cranking of the engine.

    OK:
    Engine cranks.



NG
Go to step 2
OK

GO TO PROBLEM SYMPTOMS TABLE (Click here)

2. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the engine switch on (IG) and turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Activate Test / Activate the Starter Relay.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / Starter Signal.

  1. Check the Starter Signal on the intelligent tester.

    OK:
    Activate Test
    Starter Signal
    ON
    ON
    OFF
    OFF

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 9
A


3. CHECK MAIN BODY ECU RH (COWL SIDE JUNCTION BLOCK RH) (STSW VOLTAGE)
A164768E06
  1. Disconnect the ECM connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage (for LHD):
    Tester Connection
    Condition
    Specified Condition
    A38-14 (STSW) - Body ground
    Engine switch pressed and held with brake pedal depressed
    6.0 V or higher

    Standard Voltage (for RHD):
    Tester Connection
    Condition
    Specified Condition
    A52-14 (STSW) - Body ground
    Engine switch pressed and held with brake pedal depressed
    6.0 V or higher

    HINT:
    Output voltage at terminal STSW is output for 0.3 seconds when the engine starts.



NG
Go to step 13
OK


4. CHECK HARNESS AND CONNECTOR (ST CUT RELAY)
A182937E01
  1. Remove the starter cut relay (ST CUT) from the engine room relay block.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage (Relay Contact Side):
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay terminal 3 - Body ground
    While engine is cranking
    11 to 14 V

    Standard Voltage (Relay Coil Side):
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay terminal 3 - Body ground
    Always
    11 to 14 V

    Result 
    Result
    Proceed to
    OK
    A
    NG (Relay Contact Side)
    B
    NG (Relay Coil Side)
    C



B
Go to step 14

C
Go to step 17
A


5. INSPECT STARTER CUT RELAY (ST CUT)

  1. A182937E01
    Remove the starter cut relay (ST CUT) from the engine room relay block.

  1. B016200E02
    Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Battery voltage applied to terminals 1 and 2
    Below 1 Ω



NG
REPLACE STARTER CUT RELAY (ST CUT)
OK


6. INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY
A107908E35
  1. Disconnect the PNP switch connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    4 (B) - 5 (L)
    Shift lever in P or N
    Below 1 Ω
    4 (B) - 5 (L)
    Shift lever not in P or N
    10 kΩ or higher



NG
REPLACE PARK/NEUTRAL POSITION SWITCH ASSEMBLY (Click here)
OK


7. CHECK HARNESS AND CONNECTOR (ST CUT RELAY - PNP SWITCH)
A182030E01
  1. Disconnect the PNP switch connector.

  1. Remove the starter cut relay (ST CUT) from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay terminal 5 - C24-4 (B)
    Always
    Below 1 Ω
    ST CUT relay terminal 5 or C24-4 (B) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8. CHECK HARNESS AND CONNECTOR (ECM - ST CUT RELAY)
A181636E01
  1. Move the shift lever to P or N.

  1. Disconnect the ECM connector.

  1. Remove the ST CUT relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (for LHD):
    Tester Connection
    Condition
    Specified Condition
    A38-46 (STA) - ST CUT relay terminal 3
    Always
    Below 1 Ω
    A38-46 (STA) or ST CUT relay terminal 3 - Body ground
    Always
    10 kΩ or more

    Standard Resistance (for RHD):
    Tester Connection
    Condition
    Specified Condition
    A52-46 (STA) - ST CUT relay terminal 3
    Always
    Below 1 Ω
    A52-46 (STA) or ST CUT relay terminal 3 - Body ground
    Always
    10 kΩ or more



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9. INSPECT STARTER RELAY (ST)

  1. A182938E01
    Remove the starter relay (ST) from the engine room relay block.

  1. B016200E02
    Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage not applied to terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Battery voltage applied to terminals 1 and 2
    Below 1 Ω



NG
REPLACE STARTER RELAY
OK


10. CHECK HARNESS AND CONNECTOR (ST RELAY)
A182938E01
  1. Remove the starter relay (ST) from the engine room relay block.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    ST relay terminal 1 - 2
    While engine is cranking
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (PNP SWITCH - ST RELAY BODY GROUND)
OK


11. CHECK HARNESS AND CONNECTOR (STARTER VOLTAGE)
A182938E01
  1. Remove the starter relay (ST) from the engine room relay block.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    ST relay terminal 5 - Body ground
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (STARTER RELAY (ST) - BATTERY)
OK


12. CHECK HARNESS AND CONNECTOR (STARTER - ST RELAY)
A182938E01
  1. Disconnect the starter connector.

  1. Remove the starter relay (ST) from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    D2 - ST relay terminal 3
    Always
    Below 1 Ω
    D2 or ST relay terminal 3 - Body ground
    Always
    10 kΩ or higher

    Result 
    Result
    Proceed to
    NG
    A
    OK (for 1.4 kW type)
    B
    OK (for 2.0 kW type)
    C



B
REPAIR OR REPLACE STARTER ASSEMBLY (Click here)

C
REPAIR OR REPLACE STARTER ASSEMBLY (Click here)
A

REPAIR OR REPLACE HARNESS OR CONNECTOR

13. CHECK HARNESS AND CONNECTOR (ECM - MAIN BODY ECU)

  1. A182031E01
    Disconnect the ECM connector.

  1. Disconnect the main body ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (for LHD):
    Tester Connection
    Condition
    Specified Condition
    A38-14 (STSW) - E4-4 (STSW)
    Always
    Below 1 Ω
    A38-14 (STSW) or E4-4 (STSW) - Body ground
    Always
    10 kΩ or higher

    Standard resistance (for RHD):
    Tester Connection
    Condition
    Specified Condition
    A52-14 (STSW) - E4-4 (STSW)
    Always
    Below 1 Ω
    A52-14 (STSW) or E4-4 (STSW) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

GO TO ENTRY AND START SYSTEM (Click here)

14. CHECK HARNESS AND CONNECTOR (ECM - ST CUT RELAY)
A182497E01
  1. Disconnect the ECM connector.

  1. Remove the starter cut relay (ST CUT) from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (for LHD):
    Tester Connection
    Condition
    Specified Condition
    C45-16 (STAR) - ST CUT relay terminal 5
    Always
    Below 1 Ω
    C45-16 (STAR) or ST CUT relay terminal 5 - Body ground
    Always
    10 kΩ or higher

    Standard Resistance (for RHD):
    Tester Connection
    Condition
    Specified Condition
    C46-16 (STAR) - ST CUT relay terminal 5
    Always
    Below 1 Ω
    C46-16 (STAR) or ST CUT relay terminal 5 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


15. REPLACE ECM
  1. Replace the ECM (Click here).


NEXT


16. CHECK PROBLEM SYMPTOM DISAPPEARS
  1. Check if the problem symptom disappears.

    Result 
    Result
    Proceed to
    Problem symptom disappears
    A
    Problem symptom does not disappear
    B



B
GO TO PROBLEM SYMPTOMS TABLE (Click here)
A

END

17. CHECK HARNESS AND CONNECTOR (ST CUT RELAY - IGN FUSE)
A182044E01
  1. Remove the starter cut relay (ST CUT) and IGN fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay terminal 2 - IGN fuse terminal 2
    Always
    Below 1 Ω
    ST CUT relay terminal 1 - Body ground
    Always
    Below 1 Ω
    ST CUT relay terminal 2 or IGN fuse terminal 2 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

GO TO ECU POWER SOURCE CIRCUIT (Click here)


← Fuel Injector Circuit (Sep 2011 – Dec 2011)ACIS Control Circuit (Sep 2011 – Dec 2011) →