Home › Power Source / Network › 1GR-FE (BATTERY / CHARGING) › CHARGING SYSTEM
RM38G0E _57 Power Source / Network _101114 1GR-FE BATTERY / CHARGING _0469187 CHARGING SYSTEM C

1GR-FE BATTERY / CHARGING  CHARGING SYSTEM  P065C07  Generator "A" Mechanical Performance Mechanical Failure  


DESCRIPTION

The alternator performs self-diagnosis of its internal circuits to detect malfunctions (open or short circuits).

The ECM receives the result via LIN communication and stores a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate Note
P065C07 Generator "A" Mechanical Performance Mechanical Failure Alternator speed is less than 560 rpm, and F circuit is ON.
(1 trip detection logic)
·

Fan and generator V belt

·

V-Ribbed belt tensioner assembly

·

Generator assembly wiring

·

Generator assembly


Charge warning is displayed SAE: P065C

HINT:

A charge warning is displayed only when the malfunction continues.


WIRING DIAGRAM

Refer to the wiring diagram for the P161A87.

Click herePower Source / Network>1GR-FE (BATTERY / CHARGING)>CHARGING SYSTEM>P161A87

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses for circuits related to this system before performing the following procedure.


PROCEDURE

1.CHECK FAN AND GENERATOR V BELT

OK

2.CHECK V-RIBBED BELT TENSIONER ASSEMBLY

NG

REPAIR OR REPLACE FAN AND GENERATOR V BELT

2.CHECK V-RIBBED BELT TENSIONER ASSEMBLY

OK

3.CHECK GENERATOR ASSEMBLY WIRING

NG

REPAIR OR REPLACE V-RIBBED BELT TENSIONER ASSEMBLY

3.CHECK GENERATOR ASSEMBLY WIRING

OK

4.CHECK FOR ABNORMAL NOISE

NG

REPAIR OR REPLACE GENERATOR ASSEMBLY WIRING

4.CHECK FOR ABNORMAL NOISE

OK

5.CHARGING CIRCUIT WITHOUT LOAD

NG

5.CHARGING CIRCUIT WITHOUT LOAD

OK

6.CHARGING CIRCUIT WITH LOAD

NG

REPAIR OR REPLACE GENERATOR ASSEMBLY