Home › Engine / Hybrid System › F33A-FTV (ENGINE CONTROL) › ECD SYSTEM (w/o DPF) › from 2021.07
RM38G0E _51 Engine / Hybrid System _106329 F33A-FTV ENGINE CONTROL _0484891 ECD SYSTEM(w/o DPF) C

F33A-FTV ENGINE CONTROL  ECD SYSTEM(w/o DPF)  P04807F  Fan 1 Performance/Stuck Off Actuator Stuck Off  


DESCRIPTION

Refer to DTC P048012.

Click hereEngine / Hybrid System>F33A-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>P048012

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Note
P04807F Fan 1 Performance/Stuck Off Actuator Stuck Off When the engine coolant temperature, air conditioning refrigerant pressure or exhaust gas temperature is high and the target engagement rate of the coupling fan is 80% or more, the coupling fan speed is lower than the stuck closed judgment speed for 60 seconds or more.
(1 trip detection logic)
·

Fluid coupling assembly

·

Wire harness or connector

·

Fan and generator V belt

·

V-Ribbed belt tensioner assembly

·

ECM


Does not come on SAE Code: P2B2F

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses for circuits related to this system before performing the following procedure.



HINT:

Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.


PROCEDURE

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P04807F)
a.

Read the DTCs.

Powertrain > Engine > Trouble Codes
50001 372
Result:
Result Proceed to
P04807F and other DTCs are output A
P04807F is output B


HINT:

If any DTCs other than P04807F are output, troubleshoot those DTCs first.




A

GO TO DTC CHART

B

2.INSPECT FAN AND GENERATOR V BELT
2.INSPECT FAN AND GENERATOR V BELT

OK

3.CHECK V-RIBBED BELT TENSIONER ASSEMBLY

NG

3.CHECK V-RIBBED BELT TENSIONER ASSEMBLY

OK

4.INSPECT ECM (GDFC TERMINAL)

NG

REPLACE V-RIBBED BELT TENSIONER ASSEMBLY

4.INSPECT ECM (GDFC TERMINAL)
a.

Disconnect the fan control solenoid (fluid coupling assembly) connector.


b.

Operate the fan control solenoid using the Active Test function and measure the resistance according to the value(s) in the table below.

Powertrain > Engine > Active Test
Tester Display
Control the Electronic Control Coupling Fan
50004 372 99
Standard Resistance:
Tester Connection GTS Operation Specified Condition

Click Location & Routing(C165)Location & Routing

Click Connector(C165)Engine Compartment>Connecting Wire / Cooling Fan Wire / Engine Wire / Fuel Pump Motor Wire / No. 1 Connecting Wire / No. 10 Engine Wire / No. 2 Connecting Wire / No. 3 Connecting Wire / No. 4 Connecting Wire / Sensor Wire / Turbocharger Wire>Fluid Coupling Assembly

C165-3 (GDFC) - Body ground During Active Test Resistance fluctuates*


HINT:

*: Using the Active Test, duty control of the transistors in the ECM will be performed. Due to the duty control, resistance of the GDFC terminal will be unstable during the Active Test. If the resistance fluctuates while performing the Active Test, it can be determined that the transistor is operating. If the transistor does not operate during the Active Test, the ECM may be malfunctioning.



Result:
Proceed to
OK
NG



OK

REPLACE FLUID COUPLING ASSEMBLY

NG