MALFUNCTION DESCRIPTION
The EV control ECU detects malfunctions in the disconnect signal (FSDN signal) to the FCDC converter control ECU.
The cause of this malfunction may be one of the following:
Wire harness malfunction
FCDC converter control ECU malfunction
EV Control ECU malfunction
Refer to the wiring diagram for DTC P321E9F.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P321E9F
Refer to boost system diagram for the System Description.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>SYSTEM DESCRIPTION
If necessary, the EV control ECU shuts off the operation of the FC converter power module transistor by sending the shut off signal (FSDN signal) to the FCDC converter control ECU.
If only either of the inverter with converter assembly and the FC converter power module transistor is shut off, difference in voltage may occur, and this may cause malfunctions such as a fuse blow. To prevent this, if the FCDC converter control ECU detects the shut off of the FC converter power module transistor, it immediately sends the converter fail signal (ISDN signal) to the EV control ECU.
When the EV control ECU receives the ISDN signal, it sends the HSDN signal (MG shut down signal) to the motor generator control ECU (MG ECU), and then shuts off the power supply to both the drive motor and FC air compressor motor, simultaneously.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1D9512 | FC Converter Shutdown Signal Circuit Short to Battery | The FSDN signal from the EV control ECU is OFF but the CPU monitored value of the ISDN signal is ON.
(1 trip detection logic) |
·
Wire harness or connector ·
EV Control ECU ·
FCDC converter control ECU board sub-assembly |
Master Warning:
Comes on |
EV | A |
| P1D9514 | FC Converter Shutdown Signal Circuit Short to Ground or Open | The FSDN signal from the EV control ECU is ON but the CPU monitored value of the ISDN signal is OFF.
(1 trip detection logic) |
·
Wire harness or connector ·
EV Control ECU ·
FCDC converter control ECU board sub-assembly |
Master Warning:
Comes on |
EV | A |
| DTC No. | ECU Data List |
|---|---|
| P1D9512
P1D9514 |
·
FC Emergency Shutdown Signal ·
FC Converter Shutdown Request |
After the repair, perform the following procedure to confirm the repair.
Turn the ignition switch off and wait for 10 minutes or more.
Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
Turn the ignition switch off and wait for 10 minutes or more.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for the Shut Down Signal Circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Shut Down Signal Circuit
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
Since high voltage accumulates within the FC stack assembly with FC converter, never perform the work of separating the FC stack assembly with FC converter into the FC converter assembly and FC stack assembly without first performing electrical charge discharge (forced electrical charge discharge or electrical charge self-discharge), because doing so is dangerous.
Click hereEngine / Hybrid System>FC CONTROL>FC STACK>REMOVAL
Removing and installing the FC stack assembly without first discharging the electrical charge may result in an electric shock due to the high voltage circuit.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1D9512 or P1D9514 only is output, or DTCs except the ones in the table below are also output. | A |
| DTCs of hybrid control system in the tables below are output. | B |
| DTCs of FC control system in the tables below are output. | C |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Micro computer malfunction | Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure | ||
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ||
| P1C9E9F | Hybrid/EV System Reset Stuck Off | ||
| FC control system | P060B49 | Internal Control Module A/D Processing Performance Internal Electronic Failure | |
| P060B71 | Internal Control Module A/D Processing Performance Actuator Stuck | ||
| P060B1C | Internal Control Module A/D Processing Performance Circuit Voltage Out of Range | ||
| P060B16 | Internal Control Module A/D Processing Performance Circuit Voltage Below Threshold | ||
| Power source circuit malfunction | FC control system | P1F451F | FC Converter Control Module Power Relay Sense Circuit Intermittent |
| P1F651C | FC Converter Control Module Power Supply (-5V) Circuit Voltage Out of Range | ||
| P1F661C | FC Converter Control Module Power Supply (+V5AREF) Circuit Voltage Out of Range | ||
| Communication system malfunction | Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| FC control system | U116087 | Lost Communication with Hydrogen Filling Control Module Missing Message | |
| U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | ||
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1D0619
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the electric heater sub-assembly.
Disconnect the B6 FC converter assembly connector.
Disconnect the A17 EV Control ECU connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Front view of wire harness connector
(to FC Converter Assembly) |
*b | Rear view of wire harness connector
(to EV Control ECU) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B6,A17)Location & Routingewd_type=routing;type=c,c;code=B6,A17 Click Connector(B6)Engine Compartment>No. 2 Stack Wire>FC Converter Assemblyewd_type=component;type=c;code=B6;pinno=1 Click Connector(A17)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A17;pinno=2 |
||
| B6-1 (FSDN) - A17-2 (FSDN) | Ignition switch off | Below 1 Ω |
| B6-1 (FSDN) or A17-2 (FSDN) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the B6 FC converter assembly connector.
Reconnect the A17 EV Control ECU connector.
Install the electric heater sub-assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the electric heater sub-assembly.
Disconnect the B6 FC converter assembly connector.
Procedure1
| *a | Component without harness connected
(FC Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(B6)Location & Routingewd_type=routing;type=c;code=B6 Click Connector(B6)Engine Compartment>No. 2 Stack Wire>FC Converter Assemblyewd_type=component;type=c;code=B6;pinno=1,10,12,2,11,13,6 |
||
| B6-1 (FSDN) - B6-10 (E1) | Ignition switch off | 2.65 to 3.55 kΩ |
| B6-1 (FSDN) - B6-12 (+B1) | Ignition switch off | 5 kΩ or higher |
| B6-1 (FSDN) - B6-2 (DRN0) | Ignition switch off | 10 kΩ or higher |
| B6-1 (FSDN) - B6-11 (E2) | Ignition switch off | 10 kΩ or higher |
| B6-1 (FSDN) - B6-13 (+B2) | Ignition switch off | 5 kΩ or higher |
| B6-1 (FSDN) - B6-6 (IG2) | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the B6 FC converter assembly connector.
Install the electric heater sub-assembly.
OK
NG
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT