| P009A62
|
Intake Air Temperature/Ambient Air Temperature Correlation Signal Compare Failure
|
Master Warning: Comes on
|
EV
|
A
|
|
| P010031
|
Mass or Volume Air Flow Sensor "A" No Signal
|
Master Warning: Comes on
|
EV
|
A
|
|
| P011011
|
Intake Air Temperature Sensor 1 Bank 1 Circuit Short to Ground
|
Master Warning: Comes on
|
EV
|
A
|
|
| P011015
|
Intake Air Temperature Sensor 1 Bank 1 Circuit Short to Battery or Open
|
Master Warning: Comes on
|
EV
|
A
|
|
| P060B16
|
Internal Control Module A/D Processing Performance Circuit Voltage Below Threshold
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P060B1C
|
Internal Control Module A/D Processing Performance Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FC
|
B
|
|
| P060B1C
|
Internal Control Module A/D Processing Performance Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P060B49
|
Internal Control Module A/D Processing Performance Internal Electronic Failure
|
Master Warning: Comes on
|
FC
|
B
|
|
| P060B49
|
Internal Control Module A/D Processing Performance Internal Electronic Failure
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P060B71
|
Internal Control Module A/D Processing Performance Actuator Stuck
|
Master Warning: Comes on
|
FC
|
B
|
|
| P060B71
|
Internal Control Module A/D Processing Performance Actuator Stuck
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P062F00
|
Internal Control Module EEPROM Error
|
Master Warning:
Does not come on
|
EV
|
A
|
|
| P19FD73
|
Air Conditioner Power Supply Relay Actuator Stuck Closed
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D0618
|
FC Converter Phase U Current Circuit Current Below Threshold
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D0619
|
FC Converter Phase U Current Circuit Current Above Threshold
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D0718
|
FC Converter Phase V Current Circuit Current Below Threshold
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D0719
|
FC Converter Phase V Current Circuit Current Above Threshold
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D0818
|
FC Converter Phase W Current Circuit Current Below Threshold
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D0819
|
FC Converter Phase W Current Circuit Current Above Threshold
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D0918
|
FC Converter Phase X Current Circuit Current Below Threshold
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D0919
|
FC Converter Phase X Current Circuit Current Above Threshold
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D0E62
|
Inverter Output Voltage/FC Converter Output Voltage Signal Compare Failure
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D0F62
|
Cell Monitor Voltage/FC Converter Input Voltage Signal Compare Failure
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D1C16
|
FC Converter Output Voltage Sensor Circuit Voltage Below Threshold
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D1C17
|
FC Converter Output Voltage Sensor Circuit Voltage Above Threshold
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D2017
|
FC Converter Input Voltage Sensor Circuit Voltage Above Threshold
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D2496
|
Hydrogen Pump Component Internal Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1D2511
|
Radiator Outlet Coolant Temperature Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D2515
|
Radiator Outlet Coolant Temperature Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D251C
|
Radiator Outlet Coolant Temperature Sensor Circuit Voltage Out of Range
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1D2A11
|
FC Stack Outlet Coolant Temperature Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D2A15
|
FC Stack Outlet Coolant Temperature Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D2A1C
|
FC Stack Outlet Coolant Temperature Sensor Circuit Voltage Out of Range
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1D2F00
|
FC Coolant Pump Performance
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1D2F96
|
FC Coolant Pump Component Internal Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1D3011
|
Phase U Reactor Current Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D3015
|
Phase U Reactor Current Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D301C
|
Phase U Reactor Current Sensor Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D3028
|
Phase U Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D3511
|
Phase V Reactor Current Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D3515
|
Phase V Reactor Current Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D351C
|
Phase V Reactor Current Sensor Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D3528
|
Phase V Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D3A11
|
Phase W Reactor Current Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D3A15
|
Phase W Reactor Current Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D3A1C
|
Phase W Reactor Current Sensor Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D3A28
|
Phase W Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D3F16
|
FC Stack Internal Voltage Circuit Voltage Below Threshold
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1D4011
|
Phase X Reactor Current Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D4015
|
Phase X Reactor Current Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D401C
|
Phase X Reactor Current Sensor Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D4028
|
Phase X Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D4512
|
Phase U Temperature Sensor Circuit Short to Battery
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D4514
|
Phase U Temperature Sensor Circuit Short to Ground or Open
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D4A12
|
Phase V Temperature Sensor Circuit Short to Battery
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D4A14
|
Phase V Temperature Sensor Circuit Short to Ground or Open
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D4F62
|
Total Reactor Current/FC Current Signal Compare Failure
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1D5012
|
Phase W Temperature Sensor Circuit Short to Battery
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D5014
|
Phase W Temperature Sensor Circuit Short to Ground or Open
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D5512
|
Phase X Temperature Sensor Circuit Short to Battery
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D5514
|
Phase X Temperature Sensor Circuit Short to Ground or Open
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D5F87
|
Lost Communication with Cell Monitor Missing Message
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1D7F62
|
FC Air Compressor Motor Signal Compare Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1D7F96
|
FC Air Compressor Motor Component Internal Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1D8387
|
Lost Communication with Hydrogen Pump Inverter Missing Message
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D8396
|
Hydrogen Pump Inverter Component Internal Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1D8511
|
Hydrogen Pump Motor Temperature Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D8515
|
Hydrogen Pump Motor Temperature Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D8A11
|
FC Inter Cooler Outlet Temperature Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D8A15
|
FC Inter Cooler Outlet Temperature Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D8F00
|
FC Air Compressor Motor Control Module Performance
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D9011
|
FC Stack Inlet Pressure Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D9015
|
FC Stack Inlet Pressure Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1D9A1C
|
Hydrogen Injector 1 Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DA01C
|
Hydrogen Injector 2 Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DA51C
|
Hydrogen Injector 3 Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DAA12
|
Exhaust Drainage Valve Circuit Short to Battery
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DAA14
|
Exhaust Drainage Valve Circuit Short to Ground or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DB011
|
High-Range Hydrogen Pressure Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DB015
|
High-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DB01C
|
High-Range Hydrogen Pressure Sensor Circuit Voltage Out of Range
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DB511
|
Medium-Range Hydrogen Pressure Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DB515
|
Medium-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DBA11
|
Low-Range Hydrogen Pressure Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DBA15
|
Low-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DC000
|
Low-Range Hydrogen Pressure Too Low
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DC100
|
Low-Range Hydrogen Pressure Too High
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DC300
|
Medium-Range Hydrogen Pressure Too High
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DC500
|
FC Air Pressure Too High
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DC618
|
Air Sealing Valve Circuit Current Below Threshold
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DC619
|
Air Sealing Valve Circuit Current Above Threshold
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DC711
|
Air Sealing Valve Position Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DC715
|
Air Sealing Valve Position Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DC887
|
Lost Communication with FC Coolant Pump Inverter Missing Message
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1DC896
|
FC Coolant Pump Inverter Component Internal Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DCA31
|
Hydrogen Detector (Motor Room) No Signal
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1DCF96
|
Cell Monitor Component Internal Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DD031
|
Hydrogen Detector Sensor "A" No Signal
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1DD514
|
Radiator Rotary Valve Circuit 1 Circuit Short to Ground or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1DDA00
|
FC Converter Phase U Performance
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDA4B
|
FC Converter Phase U Over Temperature
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDA9E
|
FC Converter Phase U Fail Signal Stuck On
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDB00
|
FC Converter Phase V Performance
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDB4B
|
FC Converter Phase V Over Temperature
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDB9E
|
FC Converter Phase V Fail Signal Stuck On
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDC00
|
FC Converter Phase W Performance
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDC4B
|
FC Converter Phase W Over Temperature
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDC9E
|
FC Converter Phase W Fail Signal Stuck On
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDD00
|
FC Converter Phase X Performance
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDD4B
|
FC Converter Phase X Over Temperature
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDD9E
|
FC Converter Phase X Fail Signal Stuck On
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1DDE31
|
Hydrogen Detector Sensor "B" No Signal
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1DDF00
|
FC Air Flow Malfunction
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DDF79
|
FC Air Flow Mechanical Linkage Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DE400
|
FC Cooling System Performance
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DE511
|
Hydrogen Tank 1 Temperature Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1DE515
|
Hydrogen Tank 1 Temperature Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1DE51C
|
Hydrogen Tank 1 Temperature Sensor Circuit Voltage Out of Range
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1DEA11
|
Hydrogen Tank 2 Temperature Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1DEA15
|
Hydrogen Tank 2 Temperature Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1DEF00
|
FC System No Activation
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1DFA11
|
Hydrogen Intake Pressure Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1DFA15
|
Hydrogen Intake Pressure Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1E0012
|
Tank Shut Valve 1 Circuit Short to Battery
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1E0014
|
Tank Shut Valve 1 Circuit Short to Ground or Open
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1E1012
|
Tank Shut Valve 2 Circuit Short to Battery
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1E1014
|
Tank Shut Valve 2 Circuit Short to Ground or Open
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1E1996
|
Infrared Transmitter Component Internal Failure
|
Master Warning: Does not come on
|
Hydrogen Filling Control
|
A
|
|
| P1E367E
|
Tank Shut Valve 1 Actuator Stuck On
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1E4000
|
Extreme Hydrogen Leak (Motor Room)
|
·
Hydrogen Leak Warning: Comes on
|
EV
|
B
|
|
| P1E407A
|
Hydrogen Leak (Motor Room) Fluid Leak or Seal Failure
|
Hydrogen Leak Warning: Comes on
|
EV
|
B
|
|
| P1E4100
|
Extreme Hydrogen Leak (Tank Area 1)
|
·
Hydrogen Leak Warning: Comes on
|
EV
|
B
|
|
| P1E417A
|
Hydrogen Leak (Tank Area 1) Fluid Leak or Seal Failure
|
Hydrogen Leak Warning: Comes on
|
EV
|
B
|
|
| P1E427A
|
Hydrogen Leak (Excessive Hydrogen Flow) Fluid Leak or Seal Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1E437A
|
Hydrogen Leak (High/Medium Pressure Area) Fluid Leak or Seal Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1E447A
|
Hydrogen Leak (Low Pressure Area) Fluid Leak or Seal Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1E4862
|
FC Stack Inlet Pressure Sensor/Barometric Pressure Sensor "B" Signal Compare Failure
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1E4A11
|
Hydrogen Tank 3 Temperature Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1E4A15
|
Hydrogen Tank 3 Temperature Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1E5A12
|
Tank Shut Valve 3 Circuit Short to Battery
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1E5A14
|
Tank Shut Valve 3 Circuit Short to Ground or Open
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|
| P1E6B73
|
Fuel Lid Interlock Actuator Stuck Closed
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1E7A18
|
Air Shunt Valve Circuit Current Below Threshold
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1E7A19
|
Air Shunt Valve Circuit Current Above Threshold
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1E7B11
|
Air Shunt Valve Position Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1E7B15
|
Air Shunt Valve Position Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1E7C18
|
Air Pressure Regulating Valve Circuit Current Below Threshold
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1E7C19
|
Air Pressure Regulating Valve Circuit Current Above Threshold
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1E7D11
|
Air Pressure Regulating Valve Position Sensor Circuit Short to Ground
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1E7D15
|
Air Pressure Regulating Valve Position Sensor Circuit Short to Battery or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1E7E87
|
Lost Communication with Hybrid/EV Powertrain Control Module (SIL) Missing Message
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1E7F87
|
Communication Error from Fuel Cell Control Module to Hybrid/EV Powertrain Control Module Missing Message
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1E9011
|
FC Positive Contactor Control Circuit Short to Ground
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1E9015
|
FC Positive Contactor Control Circuit Short to Battery or Open
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1E9111
|
FC Negative Contactor Control Circuit Short to Ground
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1E9115
|
FC Negative Contactor Control Circuit Short to Battery or Open
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1E9211
|
FC Precharge Contactor Control Circuit Short to Ground
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1E9215
|
FC Precharge Contactor Control Circuit Short to Battery or Open
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1EF214
|
Air Valve Supply Voltage Circuit Short to Ground or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1EF394
|
Fuel Cell Control Module Unexpected Operation
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1EF581
|
Invalid Data Received from Water Heating Heater Invalid Serial Data Received
|
Master Warning:
Does not come on
|
EV
|
B
|
|
| P1EF600
|
Extreme Hydrogen Leak (Tank Area 2)
|
·
Hydrogen Leak Warning: Comes on
|
EV
|
B
|
|
| P1EF67A
|
Hydrogen Leak (Tank Area 2) Fluid Leak or Seal Failure
|
Hydrogen Leak Warning: Comes on
|
EV
|
B
|
|
| P1EFD14
|
Radiator Rotary Valve Circuit 2 Circuit Short to Ground or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1EFE14
|
Radiator Rotary Valve Circuit 3 Circuit Short to Ground or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1EFF14
|
Radiator Rotary Valve Circuit 4 Circuit Short to Ground or Open
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1F009E
|
FC Converter Overvoltage Signal Stuck On
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1F0117
|
FC Converter Output Voltage Circuit Voltage Above Threshold
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| P1F089F
|
FC Shutdown Signal Stuck Off
|
Master Warning: Comes on
|
EV
|
A
|
|
| P1F451F
|
FC Converter Control Module Power Relay Sense Circuit Intermittent
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1F4A1F
|
Fuel Cell Control Module Power Relay Sense Circuit Intermittent
|
Master Warning: Comes on
|
FC
|
A
|
|
| P1F651C
|
FC Converter Control Module Power Supply (-5V) Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1F661C
|
FC Converter Control Module Power Supply (+V5AREF) Circuit Voltage Out of Range
|
Master Warning: Comes on
|
FCDC
|
A
|
|
| P1F6C71
|
Air Sealing Valve Actuator Stuck
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1F6D71
|
Air Shunt Valve Actuator Stuck
|
Master Warning: Comes on
|
EV
|
B
|
|
| P1F6E71
|
Air Pressure Regulating Valve Actuator Stuck
|
Master Warning: Comes on
|
EV
|
B
|
|
| P222A12
|
Barometric Pressure Sensor "B" Circuit Short to Battery
|
Master Warning: Comes on
|
EV
|
A
|
|
| P222A14
|
Barometric Pressure Sensor "B" Circuit Short to Ground or Open
|
Master Warning: Comes on
|
EV
|
A
|
|
| U029387
|
Lost Communication with Hybrid/EV Powertrain Control Module Missing Message
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
B
|
|
| U029387
|
Lost Communication with Hybrid/EV Powertrain Control Module Missing Message
|
Master Warning: Comes on
|
FCDC
|
B
|
|
| U116087
|
Lost Communication with FCDC Control Module Missing Message
|
Master Warning: Comes on
|
EV
|
B
|
|
| U116287
|
Lost Communication with Hydrogen Filling Control Module Missing Message
|
Master Warning: Comes on
|
EV
|
B
|
|
| U149257
|
Software incompatibility with Hybrid/EV Powertrain Control Module Invalid/Incompatible Software Component
|
Master Warning: Comes on
|
Hydrogen Filling Control
|
A
|
|