HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P31B300  Hybrid/EV Battery Voltage High  


DTC SUMMARY

MALFUNCTION DESCRIPTION


The EV control ECU uses the inverter voltage to monitor the EV supply battery assembly voltage and detect malfunctions.

The cause of this malfunction may be the following:

Inverter with converter assembly malfunction (Boost converter system)
·

VL sensor malfunction

·

VH sensor malfunction


HV battery system
·

Battery ECU assembly malfunction

·

EV supply battery assembly malfunction



DESCRIPTION

The EV control ECU uses the inverter voltage to monitor the EV supply battery assembly voltage and detect malfunctions.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P31B300 Hybrid/EV Battery Voltage High The inverter voltage exceeds the threshold.
(1 trip detection logic)
·

Inverter with converter assembly

·

Battery ECU assembly

·

Battery voltage sensor (for upper side)

·

Battery voltage sensor (for lower side)


Master Warning:
Comes on
EV A

Related Data List
DTC No. Data List
P31B300 -

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 10 minutes or more.

3.

Turn the ignition switch to ON (READY) and wait for 30 seconds or more.

4.

Enter the following menus: Powertrain / EV / Utility / All Readiness.

5.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




WIRING DIAGRAM

Refer to the wiring diagram for the HV battery high-voltage line circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>HV Battery High-voltage Line Circuit

CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.

Make sure to remove the service plug grip first.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the EV supply battery assembly

-

Disconnecting the low voltage connector of the FC converter assembly


·
A484004

To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.

-

The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.

-

Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.


·
A484005C01
1.667,0.74 2.115,0.427 true 2.188,0.385 2.448,0.552 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.

If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.

·
A358021C04
0.552,4.156 0.865,4.354 0.313,0.198 10 false *a 2.76,4.167 3.073,4.365 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


When disposing of an EV supply battery assembly, make sure to return it through an authorized collection agent who is capable of handling it safely. If the EV supply battery assembly is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

-

Accidents such as electric shock may result if the EV supply battery assembly or the EV supply stack sub-assembly is disposed of improperly or abandoned.

Therefore, make sure to return EV supply battery assembly and all EV supply stack sub-assemblies through an authorized collection agent.


·

Before returning the EV supply battery assembly, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION

·

Before returning the EV supply stack sub-assembly, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>RECOVERY INSPECTION

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the EV supply battery assembly and EV supply stack sub-assemblies.

·
A358020

After removing the EV supply battery assembly or the EV supply stack sub-assembly, keep it away from water. Exposure to water may cause the EV supply battery assembly or the EV supply stack sub-assembly to produce heat, resulting in a fire.



NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART


·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



PROCEDURE

1.CHECK DTC OUTPUT (EV)

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > EV > Trouble Codes
50001 397
Result:
Result Proceed to
Only P31B300 is output A
P31B300 and DTCs other than the DTCs in the table below are output B
P31B300 and any DTCs in the table below are output C


Malfunction Content Relevant DTC
Sensor and actuator circuit malfunction P0D2D16 Drive Motor "A" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold
P0D2D17 Drive Motor "A" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold
P0D2D1C Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range
P0E311C Boosting Converter Voltage Sensor "A" Voltage Out of Range
P1C2D62 Hybrid/EV Battery "A" Voltage Sensor / Boosting Converter Voltage Sensor "A" Signal Compare Failure
P0E3116 DC/DC Converter Voltage Sensor "A" Circuit Voltage Below Threshold
P0E3117 DC/DC Converter Voltage Sensor "A" Circuit Voltage Above Threshold
P1A7F00 DC/DC Converter "A" Overvoltage (System Performance)

HINT:
·

P31B300 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





Post-procedure1

a.

Turn the ignition switch off.



A

2.READ VALUE USING GTS (HYBRID/EV BATTERY VOLTAGE)

B

2.READ VALUE USING GTS (HYBRID/EV BATTERY VOLTAGE)

C

GO TO DTC CHART (HYBRID CONTROL SYSTEM)

2.READ VALUE USING GTS (HYBRID/EV BATTERY VOLTAGE)

Pre-procedure1

a.

None.


Procedure1

a.

Read the Data List.

Powertrain > EV Battery > Data List
Tester Display
Hybrid/EV Battery Voltage
50003 398 288
NOTICE:

Be sure not to measure when the ignition switch is ON (READY).



b.

Make a note of the data list item "Hybrid/EV Battery Voltage".

Result:
Proceed to
NEXT



Post-procedure1

a.

Turn the ignition switch off.



NEXT

3.CHECK EV SUPPLY BATTERY ASSEMBLY
3.CHECK EV SUPPLY BATTERY ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the upper EV battery cover panel.

HINT:

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY ECU>REMOVAL



c.
A479456E02
2.333,0.104 2.792,0.438 0.458,0.333 2.469,0.208 2.927,0.406 0.458,0.198 10 false z13

Disconnect the z13 EV supply battery assembly high voltage connector from the No. 1 EV battery junction block assembly (positive side).

NOTICE:

Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.



Procedure1

a.
C387670C03
1.042,0.573 1.49,0.896 0.448,0.323 1.385,1.563 1.979,1.073 true 1.667,3.417 2.188,2.854 true 0.24,0.177 0.552,0.375 0.313,0.198 10 false *a 0.25,2.49 0.563,2.688 0.313,0.198 10 true *b 1.177,0.667 1.635,0.865 0.458,0.198 10 false z13 2.031,0.927 2.188,1.125 0.156,0.198 10 false + 2.229,2.667 2.385,2.865 0.156,0.198 10 true 1
*a No. 2 EV Supply Stack Sub-assembly Connector
(to No. 1 EV Battery Junction Block Assembly (positive side))
*b Service Plug Grip Removed
(Service Plug Grip Connecting Terminals)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition

Click Location & Routing(z13)Location & Routing

Click Connector(z13)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assembly

z13-1 (+) - 1 Ignition switch off


CAUTION:

Do not allow the probes of the electrical tester to contact each other during this inspection.



b.

Check the value in the data list "Hybrid/EV Battery Voltage" and the EV battery voltage value that was actually measured.

Result:
Result Proceed to
When the difference between "Hybrid/EV Battery Voltage" in the Data List and the measurement value of the EV supply battery assembly voltage is 5 V or less. A
Other than above B



Post-procedure1

a.

Reconnect the z13 EV supply battery assembly high voltage connector from the No. 1 EV battery junction block assembly (positive side).


b.

Install the upper EV battery cover panel.



A

4.CHECK FREEZE FRAME DATA (EV)

B

REPLACE BATTERY VOLTAGE SENSOR (FOR UPPER SIDE), BATTERY VOLTAGE SENSOR (FOR LOWER SIDE) AND BATTERY ECU ASSEMBLY

4.CHECK FREEZE FRAME DATA (EV)

Pre-procedure1

a.

None.


Procedure1

a.

Read the freeze frame data of DTC P31B300.

Powertrain > EV > DTC(P31B300) > Freeze Frame Data
Tester Display
Hybrid/EV Battery Voltage
50040 397 227 P31B300
Result:
Result Proceed to
The value of Hybrid/EV Battery Voltage is 352 V or less A
None of the above conditions are met B



Post-procedure1

a.

Turn the ignition switch off.



A

REPLACE INVERTER WITH CONVERTER ASSEMBLY

B

REPLACE BATTERY VOLTAGE SENSOR (FOR UPPER SIDE), BATTERY VOLTAGE SENSOR (FOR LOWER SIDE) AND BATTERY ECU ASSEMBLY