The cause of the malfunction may be the EV supply battery high-voltage line circuit.
Check the continuity in the high-voltage line from the EV supply battery to the inverter.
Check the connection condition and for an open circuit in the frame wire from the service plug grip, EV fuse and EV supply battery to the inverter and perform a function check of the system main relay.
| Area | Inspection |
|---|---|
| High-voltage circuit from EV supply battery to inverter | Check connection condition and for open circuit. |
| Service plug grip | Check connection condition and for open circuit. |
| EV fuse | Check for open circuit. |
| System Main Relay | Check operation condition as relay. |
The EV supply battery high voltage is supplied to the inverter via the system main relay operation.
This step is referenced from the procedures for each DTC.
If the inspection results below are normal, perform the next procedure for the referenced DTC.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the electric vehicle charger assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
Since high voltage accumulates within the FC stack assembly with FC converter, never perform the work of separating the FC stack assembly with FC converter into the FC converter assembly and FC stack assembly without first performing electrical charge discharge (forced electrical charge discharge or electrical charge self-discharge), because doing so is dangerous.
Click hereEngine / Hybrid System>FC CONTROL>FC STACK>REMOVAL
Removing and installing the FC stack assembly without first discharging the electrical charge may result in an electric shock due to the high voltage circuit.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Check that the bolts for the FC junction cable is tightened to the specified torque, the FC junction cable is connected securely, and there are no contact problems.
T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)
Disconnect the FC junction cable from the inverter with converter assembly.
Procedure1
Check for arc marks on the terminals for the FC junction cable and inverter with converter assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the FC junction cable.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Check that the bolts for the FC junction cable is tightened to the specified torque, the FC junction cable is connected securely, and there are no contact problems.
T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)
Disconnect the FC junction cable from the FC converter assembly.
Procedure1
Check for arc marks on the terminals for the FC junction cable and FC converter assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the FC junction cable.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Procedure1
| *A | for LHD |
| *B | for RHD |
Check that the bolts for the floor under wire is tightened to the specified torque, the floor under wire is connected securely, and there are no contact problems.
T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)
Disconnect the floor under wire from the FC converter assembly.
Check for arc marks on the terminals for the floor under wire and FC converter assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the floor under wire.
A
B
C
Be sure to wear insulated gloves.
Check the condition of the service plug grip.
Dirt or foreign matter has not entered the connectors, and there is no evidence of contamination.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>SERVICE PLUG GRIP>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 10 EV battery shield panel.
Check that the floor under wire is connected securely, and there are no contact problems.
Disconnect the floor under wire connectors from the No. 1 EV battery junction block assembly.
Procedure1
Check for arc marks on the terminals of the floor wire and the No. 1 EV battery junction block assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the floor under wire.
Install the No. 10 EV battery shield panel.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P1C8349
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P1C8349
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the floor under wire from the FC converter assembly.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC junction cable from the FC converter assembly.
Procedure1
| *a | Component without harness connected
(FC Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(N3,x2)Location & Routingewd_type=routing;type=c,c;code=N3,x2 Click Connector(N3)Engine Compartment>Floor Under Wire>FC Converter Assemblyewd_type=component;type=c;code=N3;pinno=1,2 Click Connector(x2)Engine Compartment>FC Junction Cable>FC Converter Assemblyewd_type=component;type=c;code=x2;pinno=2,1 |
||
| N3-1 (CEI) - x2-2 (N) | Ignition switch off | Below 1 Ω |
| N3-2 (CBI) - x2-1 (P) | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC junction cable.
Reconnect the floor under wire.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>FUSE BOX>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 EV battery junction block assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 EV Battery Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z13,N1)Location & Routingewd_type=routing;type=c,c;code=z13,N1 Click Connector(z13)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z13;pinno=1 Click Connector(N1)Body>Floor Under Wire>No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=N1;pinno=1 |
||
| z13-1 (+) - N1-1 (CBI) | Auxiliary battery voltage not applied between terminals z24-1 (SMRB) and z24-3 (GND) | 10 kΩ or higher |
| z13-1 (+) - N1-1 (CBI) | Auxiliary battery voltage applied between terminals z24-1 (SMRB) and z24-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z24)Location & Routingewd_type=routing;type=c;code=z24 Click Connector(z24)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z24;pinno=1,3 |
||
| z24-1 (SMRB) - z24-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the No. 1 EV battery junction block assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Procedure1
Remove the No. 1 EV battery junction block assembly.
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 EV Battery Junction Block Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z12,N2)Location & Routingewd_type=routing;type=c,c;code=z12,N2 Click Connector(z12)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z12;pinno=1 Click Connector(N2)Body>Floor Under Wire>No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=N2;pinno=1 |
||
| z12-1 (-) - N2-1 (CEI) | Auxiliary battery voltage not applied between terminals e2-4 (SMRG) and e2-3 (GND) | 10 kΩ or higher |
| z12-1 (-) - N2-1 (CEI) | Auxiliary battery voltage applied between terminals e2-4 (SMRG) and e2-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z24)Location & Routingewd_type=routing;type=c;code=z24 Click Connector(z24)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z24;pinno=4,3 |
||
| z24-4 (SMRG) - z24-3 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the No. 1 EV battery junction block assembly.
OK
NG
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT