Home › Engine / Hybrid System › FC CONTROL › FC CONTROL SYSTEM › 2020.11–2021.08
RM37H0E _51 Engine / Hybrid System _095966 FC CONTROL _0466766 FC CONTROL SYSTEM C

FC CONTROL  FC CONTROL SYSTEM  P1D2496  Hydrogen Pump Component Internal Failure  


DESCRIPTION

The hydrogen system of the FC system feeds the FC stack with hydrogen, so that the FC stack can generate power. The hydrogen pump, which is one of the hydrogen system components, circulates a sufficient amount of hydrogen before it will eventually be supplied to the FC stack.

If the actual pump speed does not correspond to a target pump speed, it will be interpreted as a hydrogen pump error, and this DTC will be stored.

For the circuit diagram, refer to DTC P1DC000.

Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1DC000

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1D2496 Hydrogen Pump Component Internal Failure Deviation between the actual and target hydrogen pump speeds has continued at a level that exceeds the threshold. While the ignition switch is ON (READY), this malfunction detection is active all the time.
(1 trip detection logic)
·

Hydrogen recirculation pump assembly

·

Hydrogen pump inverter assembly


Master Warning: Comes on EV B

Detection timing
Vehicle Condition FC shutdown
(ignition switch ON)
FC startup process FC intermittent operation FC is generating power
(vehicle is in stationary)
FC is generating power
(vehicle is traveling)
FC shutdown process
Data List
"FC Work Mode"
Stop Startup Working Finishing
Data List
"FC Intermittent Operation"
OFF ON OFF OFF
DTC Detection - ○ ○ ○ ○ ○

HINT:

By accessing the "FC Work Mode" and "FC Intermittent Operation" in the freeze frame data, the FC system condition at the time the malfunction occurred can be checked.


Related Data List
DTC No. Data List
P1D2496
·

Hydrogen Pump Speed

·

Target Hydrogen Pump Speed

·

Hydrogen Pump Main Power Supply Status

·

Hydrogen Pump Output Status

·

Hydrogen Pump Load Status

·

Hydrogen Pump LIN Communication Control

·

Hydrogen Pump CPU Abnormal

·

Hydrogen Pump Start Fail

·

Hydrogen Pump Inverter Over Temperature Status



Related Active Test
DTC No. Active Test
P1D2496 Control the Hydrogen Pump

WIRING DIAGRAM

CAUTION / NOTICE / HINT

CAUTION:
·
A340358

A484004

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side.

Make sure to remove the EV supply battery assembly service plug grip first.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the EV supply battery assembly

-

Disconnecting the low voltage connector of the FC converter assembly


·
A341450

After removing the service plug grip from the EV supply battery assembly, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system. After removing the FC converter power outlet cable (inverter with converter assembly) on FC converter side and use the "HIGH-VOLTAGE, DO NOT TOUCH" sign to notify other technicians that you are working on the high-voltage system.

·
A484005

After removal of the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, wait for at least 10 minutes before touching the high-voltage connectors and terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>PRECAUTION

HINT:

At least 10 minutes are necessary to discharge the high-voltage capacitors inside the inverter with converter assembly and FC stack assembly.


·
A484932

Since high voltage accumulates within the FC stack assembly with FC converter, never perform the work of separating the FC stack assembly with FC converter into the FC converter assembly and FC stack assembly without first performing electrical charge discharge (forced electrical charge discharge or electrical charge self-discharge), because doing so is dangerous.

Click hereEngine / Hybrid System>FC CONTROL>FC STACK>REMOVAL

·

Removing and installing the FC stack assembly without first discharging the electrical charge may result in an electric shock due to the high voltage circuit.



NOTICE:
·

When reinstalling the service plug grip to the EV supply battery assembly, after lowering the EV supply battery assembly service plug grip 90°, securely slide it until a "click" sound is heard.

Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>PRECAUTION

·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



HINT:
·

Forcing the SOC of the EV supply battery assembly to decrease by applying electrical loads such as turning on the air conditioning (HOT MAX, maximum airflow), or depressing the accelerator pedal with the shift lever in P, the "FC Intermittent Operation" of the Data List is easily to enter OFF (power generation mode).


After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Turn the ignition switch to ON (READY) with the shift lever in P, and check that the Data List "FC Work Mode" is Working and "FC Intermittent Operation" is OFF. Then, wait for 1 minute or more.



PROCEDURE

1.CHECK DTC OUTPUT
NOTICE:

The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.


Pre-procedure1

a.

None


Procedure1

a.

According to the display on the GTS, check for DTCs in the Health Check.

Result:
Result Proceed to
Only P1D2496 is output A
P1D2496 is output and DTCs other than the DTCs in the table below are output B
P1D2496 is output and any DTCs in the table below are output C


Malfunction Content Malfunction Content
Microcomputer malfunction/Power source circuit malfunction P1D8396 (EV) Hydrogen Pump Inverter Component Internal Failure
Communication system malfunction P1D8387 (EV) Lost Communication with Hydrogen Pump Inverter Missing Message
Sensor and actuator circuit malfunction P1DAA12 (FC) Exhaust Drainage Valve Circuit Short to Battery
P1DAA14 (FC) Exhaust Drainage Valve Circuit Short to Ground or Open
System malfunction P1C8449 (Hybrid (EV) Control System) High Voltage Power Resource Circuit Short during Ready ON
P1A0F00 (Hybrid (EV) Control System) DC/DC Converter "A" Overvoltage (Control Module Performance)
P1A6F00 (Hybrid (EV) Control System) DC/DC Converter "A" Overvoltage (Inverter Performance)
P1A2F00 (Hybrid (EV) Control System) DC/DC Converter "A" Overvoltage (Position Sensor Circuit Range/Performance)
P1A7F00 (Hybrid (EV) Control System) DC/DC Converter "A" Overvoltage (System Performance)
P1A8400 (Hybrid (EV) Control System) Drive Motor "A" Inverter Overvoltage (Control Module Performance)
P1A8E00 (Hybrid (EV) Control System) Drive Motor "A" Inverter Overvoltage (Inverter Performance)
P1A8900 (Hybrid (EV) Control System) Drive Motor "A" Inverter Overvoltage (Position Sensor Circuit Range/Performance)
P1A8F00 (Hybrid (EV) Control System) Drive Motor "A" Inverter Overvoltage (System Performance)
P31B300 (Hybrid (EV) Control System) Hybrid/EV Battery Voltage High
P0A944B (Hybrid (EV) Control System) DC/DC Converter "A" Over Temperature
P1A9400 (Hybrid (EV) Control System) DC/DC Converter "A" Overcurrent (Control Module Performance)
P1AA400 (Hybrid (EV) Control System) DC/DC Converter "A" Overcurrent (Inverter Performance)
P1A9900 (Hybrid (EV) Control System) DC/DC Converter "A" Overcurrent (Position Sensor Circuit Range/Performance)
P1AA900 (Hybrid (EV) Control System) DC/DC Converter "A" Overcurrent (System Performance)
P0A949E (Hybrid (EV) Control System) DC/DC Converter "A" Fail Signal Stuck On
P1D824B (Hybrid (EV) Control System) FC Air Compressor Inverter Over Temperature
P1EF800 (Hybrid (EV) Control System) FC Air Compressor Inverter Circuit Short (Control Module Performance)
P1EFB00 (Hybrid (EV) Control System) FC Air Compressor Inverter Circuit Short (Inverter Performance)
P1EF900 (Hybrid (EV) Control System) FC Air Compressor Inverter Circuit Short (Position Sensor Circuit Range/Performance)
P1EFA00 (Hybrid (EV) Control System) FC Air Compressor Inverter Circuit Short (System Performance)
P1D829E (Hybrid (EV) Control System) FC Air Compressor Inverter Fail Signal Stuck On
P0A784B (Hybrid (EV) Control System) Drive Motor "A" Inverter Over Temperature
P1AB400 (Hybrid (EV) Control System) Drive Motor "A" Inverter Circuit Short (Control Module Performance)
P1ABF00 (Hybrid (EV) Control System) Drive Motor "A" Inverter Circuit Short (Inverter Performance)
P1AB900 (Hybrid (EV) Control System) Drive Motor "A" Inverter Circuit Short (Position Sensor Circuit Range/Performance)
P1AC300 (Hybrid (EV) Control System) Drive Motor "A" Inverter Circuit Short (System Performance)
P0A789E (Hybrid (EV) Control System) Drive Motor "A" Inverter Fail Signal Stuck On

HINT:

DTC P1D2496 may be output due to problems that cause the DTCs shown above to output. If such happens, troubleshoot the suspected area(s) corresponding to the output DTC(s) in order of the listed DTCs shown in the table above.



Post-procedure1

a.

Turn the ignition switch off.



A

2.CHECK FREEZE FRAME DATA

B

2.CHECK FREEZE FRAME DATA

C

2.CHECK FREEZE FRAME DATA

Pre-procedure1

a.

None


Procedure1

a.

Read the freeze frame data of DTC P1D2F96.

Powertrain > EV > DTC(P1D2496) > Freeze Frame Data
Tester Display
Hydrogen Pump Main Power Supply Status
Hydrogen Pump Output Status
Hydrogen Pump Load Status
Hydrogen Pump LIN Communication Control
Hydrogen Pump CPU Abnormal
Hydrogen Pump Inverter Over Temperature Status
50040 397 877,878,879,817,821,880 P1D2496
Result:
Result Proceed to
Other than below. A
The "Hydrogen Pump Output Status" of the freeze frame data shows Circuit Open. B
The "Hydrogen Pump Main Power Supply Status" of the freeze frame data shows Low Voltage or Overvoltage. C
The "Hydrogen Pump Load Status" of the freeze frame data shows Inverter Output Voltage Saturation.
The "Hydrogen Pump CPU Abnormal" of the freeze frame data shows ON.
The "Hydrogen Pump Inverter Over Temperature Status" of the freeze frame data shows Over Temperature.
The "Hydrogen Pump LIN Communication Control" of the freeze frame data shows OFF. D



Post-procedure1

a.

Turn the ignition switch off.



A

3.CHECK EXHAUST HYDROGEN GAS

B

6.CHECK HYDROGEN RECIRCULATION PUMP ASSEMBLY

C

REPLACE FC HYDROGEN PUMP INVERTER ASSEMBLY

Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL

HINT:

Replace both the FC cooling water pump inverter assembly and FC hydrogen pump inverter assembly at the same time



D

3.CHECK EXHAUST HYDROGEN GAS
CAUTION:
·

Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.

·

Accumulated hydrogen gas could ignite, resulting in a serious accident.



Pre-procedure1

a.

Ensure the safety of the areas in front and at the back of the vehicle.


b.

Put wheel chocks and securely apply the parking brake.


Procedure1

a.

Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working, "FC Intermittent Operation" is OFF, and "Exhaust Drainage Valve" is Close.

Powertrain > EV > Active Test
Active Test Display
Activate the Exhaust Drainage Valve
Data List Display
FC Work Mode
FC Intermittent Operation
Exhaust Drainage Valve
50004 397 42006 962,872,818

b.
A476956C02
0.875,2.563 1.833,1.885 true 2.042,2.042 2.75,1.583 2.75,1.583 2.938,1.573 true 0.604,2.563 0.917,2.76 0.313,0.198 10 true *1 3,1.49 3.313,1.688 0.313,0.198 10 true *2
*1 Tailpipe
*2 Hydrogen Gas Detector Probe


Use the hydrogen gas detector to measure and record the hydrogen concentration in gas released from the tailpipe when the exhaust drainage valve is closed.

NOTICE:
·

Perform this measurement in an environment where there is no wind.

·

Position the hydrogen gas detector probe in an area 100 mm (3.94 in.) away from the tailpipe opening. (Avoid locations underneath the tailpipe opening)

·

Position the hydrogen gas detector probe so that it is free from dropping water that comes from the tailpipe opening.




c.

Perform the "Activate the Exhaust Drainage Valve" Active Test several times over 1 minute, and then, starting from the third test, use the hydrogen gas detector to measure the hydrogen concentration in gas released from the tailpipe when the exhaust drainage valve is open.

HINT:
·

The exhaust drainage valve will open for 1 second each time the Active Test is performed, so measure the hydrogen concentration for several seconds.

·

Hydrogen concentration may not increase while coolant escapes when the valve is first opened. Therefore, start measuring from the third test.

·

There is a delayed response when performing detection using the hydrogen gas detector, so measure for several seconds.

·

"FC Intermittent Operation" in the Data List will be more likely to turn OFF if the accelerator pedal is depressed with the shift state in park (P).




Result:
Result Proceed to
The hydrogen concentration of the hydrogen gas detector will increase when "Exhaust Drainage Valve" in the Data List is Open rather than when "Exhaust Drainage Valve" is Close. A
Other than above* B


*: The exhaust drainage valve is malfunctioning

Exhaust drainage valve is stuck closed:

Regardless of the "Exhaust Drainage Valve Driving Request" being ON or OFF, the concentration shown on the hydrogen gas detector has remained low.


Exhaust drainage valve is stuck open:

Regardless of the "Exhaust Drainage Valve Driving Request" being ON or OFF, the concentration shown on the hydrogen gas detector has remained high when the ignition switch is on (READY).



Post-procedure1

a.

Turn the ignition switch off.



A

4.REPLACE HYDROGEN RECIRCULATION PUMP ASSEMBLY

B

REPLACE HYDROGEN RECIRCULATION SEPARATOR ASSEMBLY

4.REPLACE HYDROGEN RECIRCULATION PUMP ASSEMBLY

NEXT

5.PERFORM ACTIVE TEST USING GTS (HYDROGEN PUMP)
5.PERFORM ACTIVE TEST USING GTS (HYDROGEN PUMP)

Pre-procedure1

a.

Turn the ignition switch to ON (READY).


Procedure1

a.

Check the "Target Hydrogen Pump Speed" and "Hydrogen Pump Speed" of the Data List during an Active Test.

Powertrain > EV > Active Test
Active Test Display
Control the Hydrogen Pump
Data List Display
Hydrogen Pump Drive Speed
Hydrogen Pump Speed
Target Hydrogen Pump Speed
Hydrogen Pump Load Status
Hydrogen Pump Start Fail
50004 397 16 703,732,731,879,823
- Hydrogen Pump (Active Test)
1000 rpm 2000 rpm
Target Hydrogen Pump Speed
(Data List)
1000 rpm 2000 rpm
Hydrogen Pump Speed
(Data List)
800 to 1200 rpm 1800 to 2200 rpm

OK:

"Target Hydrogen Pump Speed" and "Hydrogen Pump Speed" change according to the command of the Active Test, and no malfunctions are shown for other Data List items.



Result:
Proceed to
OK
NG


Post-procedure1

a.

Turn the ignition switch off.



OK

END

NG

REPLACE FC HYDROGEN PUMP INVERTER ASSEMBLY

Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL

HINT:

Replace both the FC cooling water pump inverter assembly and FC hydrogen pump inverter assembly at the same time



6.CHECK HYDROGEN RECIRCULATION PUMP ASSEMBLY
CAUTION:

Be sure to wear insulated gloves.


Pre-procedure1

a.

Check that the service plug grip is not installed to EV supply battery assembly and the FC converter power outlet cable (inverter with converter assembly) is not connected to the FC converter assembly.

NOTICE:

After removing the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A479000

Disconnect the hydrogen recirculation pump assembly connector from the hydrogen pump inverter assembly.


Procedure1

a.
A478996C02
0.396,1 0.844,1.292 0.448,0.292 2.531,1.729 2.021,1.375 true 1.75,1.833 1.76,1.375 true 0.938,1.771 1.479,1.365 true 1.885,1.01 2.563,0.594 true 0.458,1.073 0.948,1.344 0.49,0.271 10 false z30 1.719,1.875 1.875,2.073 0.156,0.198 10 true V 0.135,0.135 0.479,0.344 0.344,0.208 10 false *a 2.479,1.771 2.635,1.958 0.156,0.188 10 true W 0.896,1.792 1.052,1.979 0.156,0.188 10 true U 2.604,0.542 2.948,0.75 0.344,0.208 10 false *1
*1 Shield Ground
*a Front view of wire harness connector
(to Hydrogen Pump Assembly)


Check the hydrogen pump assembly for an interphase short using a milliohmmeter.

i.

Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

HINT:

If the hydrogen pump assembly temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.


Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(z30)Location & Routing

Click Connector(z30)Engine Compartment>other>FC Converter Assembly , Hydrogen Recirculation Pump Assembly

z30-3 (W) - z30-2 (V) Ignition switch off 622 to 762 mΩ
z30-3 (W) - z30-1 (U) Ignition switch off 622 to 762 mΩ
z30-2 (V) - z30-1 (U) Ignition switch off 622 to 762 mΩ


HINT:

To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).

R20 = Rt / {1 + 0.00393 X (T - 20)}

The calculation is based on the following:

R20: Resistance at 20°C (68°F) (mΩ)

Rt: Measured resistance (mΩ)

T: Temperature when the resistance is measured (°C (°F))




b.

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(z30)Location & Routing

Click Connector(z30)Engine Compartment>other>FC Converter Assembly , Hydrogen Recirculation Pump Assembly

z30-3 (W) - Body ground and shield ground Ignition switch off 50 MΩ or higher
z30-2 (V) - Body ground and shield ground Ignition switch off 50 MΩ or higher
z30-1 (U) - Body ground and shield ground Ignition switch off 50 MΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

a.

Reconnect the hydrogen recirculation pump assembly connector to the hydrogen pump inverter assembly.



OK

REPLACE FC HYDROGEN PUMP INVERTER ASSEMBLY

Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL

HINT:

Replace both the FC cooling water pump inverter assembly and FC hydrogen pump inverter assembly at the same time



NG

REPLACE HYDROGEN RECIRCULATION PUMP ASSEMBLY