Refer to the description for DTC P0ABF11.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0ABF11
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure | The offset value of the battery current sensor is excessively large.
(1 trip detection logic) |
·
No. 1 EV battery junction block assembly ·
Battery ECU assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV Battery | A |
| DTC No. | Data List |
|---|---|
| P0ABF28 | Hybrid/EV Battery Current*1 |
*1: When the ignition switch is ON, normally the EV battery current does not flow. If the EV battery current value is above the specification, this DTC will be stored.
Make sure to perform Current Sensor Offset Learning after replacing a battery current sensor.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0C3000
This DTC may be output if Current Sensor Offset Learning has not been completed.
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 10 minutes or more.
Drive the vehicle on urban roads for approximately 10 minutes.
Turn the ignition switch off and wait for 10 minutes or more.
Turn the ignition switch to ON and wait for 10 seconds or more.
Enter the following menus: Powertrain / EV Battery / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for DTC P0ABF11.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0ABF11
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0ABF28 for Hybrid battery system is output | A |
| P0ABF28 and DTCs other than the DTCs in the table below are output | B |
| P0ABF28 and Hybrid battery system DTCs in the table below are output | C |
| P0ABF28 and Hybrid control system DTCs in the table below are output | D |
| System | Relevant DTC | |
|---|---|---|
| Hybrid battery system | P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | |
| P062F46 | Hybrid/EV Battery Energy Control Module EEPROM Calibration / Parameter Memory Failure | |
| Hybrid control system | P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
Post-procedure1
Turn the ignition switch off.
A
B
C
D
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P0A9B11
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper EV battery cover panel.
| *a | Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector) |
Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).
Make sure that the battery positive and battery negative do not contact one another.
Procedure1
| *a | Component with harness connected
(No. 1 EV Battery Junction Block Assembly (Battery Current Sensor)) |
Using a Toyota electrical tester set to 40 V, measure the VIB voltage according to the value(s) in the table below.
| Tester Connection | Tester Connection |
|---|---|
|
Click Location & Routing(z23)Location & Routingewd_type=routing;type=c;code=z23 Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z23;pinno=1,3 |
|
| z23-1 (VIB) - z23-3 (GIB) | Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND) |
Be sure to set the Toyota electrical tester to 40 V when performing this test.
| *a | Component with harness connected
(No. 1 EV Battery Junction Block Assembly (Battery Current Sensor)) |
Using a Toyota electrical tester set to 4 V, measure the IB0 voltage according to the value(s) in the table below.
| Tester Connection | Tester Connection |
|---|---|
|
Click Location & Routing(z23)Location & Routingewd_type=routing;type=c;code=z23 Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z23;pinno=4,3 |
|
| z23-4 (IB0) - z23-3 (GIB) | Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND) |
Be sure to set the Toyota electrical tester to 4 V when performing this test.
Compare the measured values of the IB0 terminal voltage and VIB terminal voltage using the following formula:
| IB0 voltage - 0.56 X VIB voltage = below 0.084 V |
| IB0 voltage - 0.56 X VIB voltage = -0.084 V or higher |
| Result | Proceed to |
|---|---|
| Within the specified range above | A |
| Other than above | B |
Post-procedure1
Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.
Install the upper EV battery cover panel.
A
B
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper EV battery cover panel.
| *a | Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector) |
Apply auxiliary battery voltage between No. 2 EV battery pack wire connector terminals G156-14 (IGCT) - G156-1 (GND).
Make sure that the battery positive and battery negative do not contact one another.
Procedure1
| *a | Component with harness connected
(No. 1 EV Battery Junction Block Assembly (Battery Current Sensor)) |
Using a Toyota electrical tester set to 40 V, measure the VIB voltage according to the value(s) in the table below.
| Tester Connection | Tester Connection |
|---|---|
|
Click Location & Routing(z23)Location & Routingewd_type=routing;type=c;code=z23 Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z23;pinno=1,3 |
|
| z23-1 (VIB) - z23-3 (GIB) | Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156-1 (GND) |
Be sure to set the Toyota electrical tester to 40 V when performing this test.
| *a | Component with harness connected
(No. 1 EV Battery Junction Block Assembly (Battery Current Sensor)) |
Using a Toyota electrical tester set to 4 V, measure the IB1 voltage according to the value(s) in the table below.
| Tester Connection | Tester Connection |
|---|---|
|
Click Location & Routing(z23)Location & Routingewd_type=routing;type=c;code=z23 Click Connector(z23)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z23;pinno=2,3 |
|
| z23-2 (IB1) - z23-3 (GIB) | Auxiliary battery positive (+) → G156-14 (IGCT)
Auxiliary battery negative (-) → G156.-1 (GND) |
Be sure to set the Toyota electrical tester to 4 V when performing this test.
Compare the measured values of the IB1 terminal voltage and VIB terminal voltage using the following formula:
| Condition |
|---|
| IB1 voltage - 0.44 X VIB voltage = below 0.078 V |
| IB1 voltage - 0.44 X VIB voltage = -0.078 V or higher |
| Result | Proceed to |
|---|---|
| Within the specified range above. | A |
| Other than above | B |
Post-procedure1
Disconnect the G156 No. 2 EV battery pack wire connector from the auxiliary battery.
Install the upper EV battery cover panel.
A
B
| Proceed to |
|---|
| NEXT |
NEXT