The battery temperature sensors are provided at 3 locations of the HV battery. The resistance of the thermistor, which is built into each battery temperature sensor, varies in accordance with changes in the HV battery temperature. The lower the battery temperature, the higher the thermistor resistance. Conversely, the higher the temperature, the lower the resistance. The battery smart unit uses the battery temperature sensors to detect the HV battery temperature, and sends the detected value to the power management control ECU. Based on the results of this detection, the power management control ECU controls the blower fan. (The blower fan starts when HV battery temperature rises above a predetermined level.)
| DTC Title Sensor | Battery Temperature Sensor | GTS Display |
|---|---|---|
| A | 0 | 1 |
| B | 1 | 2 |
| C | 2 | 3 |
For example, sensor A in the DTC title is battery temperature sensor (No. 0). This sensor is displayed as Temp of Batt TB1 in the Data List.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A9C
P0AC6 P0ACB P0AE9 P0BC3 P0C34 P3065 P306A |
123 | When the battery temperature sensor performance is abnormal (1 trip detection/2 trip detection) | ·
HV battery ·
Battery smart unit ·
Wire harness or connector |
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
A
B
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Disconnect the z24 battery smart unit connector.
Measure the resistance of the circuit for the malfunctioning sensor (battery temperature sensor 0 to 5).
| Tester Connection | Battery Temperature Sensor No. |
|---|---|
| z24-13 (TB0) - z24-1 (GB0) | 0 |
| z24-14 (TB1) - z24-2 (GB1) | 1 |
| z24-15 (TB2) - z24-3 (GB2) | 2 |
| z24-16 (TB3) - z24-4 (GB3) | 3 |
| z24-17 (TB4) - z24-5 (GB4) | 4 |
| z24-18 (TB5) - z24-6 (GB5) | 5 |
| Thermistor Temperature | Condition | Specified Condition |
|---|---|---|
| 0 °C (32 °F) | Power switch off | 26.7 to 27.8 kΩ |
| 25 °C (77 °F) | Power switch off | 9.9 to 10.1 kΩ |
| 40 °C (104 °F) | Power switch off | 5.73 to 5.92 kΩ |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Standard Resistance |
|---|---|---|
| z24-13 (TB0) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-1 (GB0) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-14 (TB1) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-2 (GB1) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-15 (TB2) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-3 (GB2) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-16 (TB3) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-4 (GB3) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-17 (TB4) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-5 (GB4) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-18 (TB5) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-6 (GB5) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-21 (TC0) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-9 (GC0) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-22 (TC1) - Body ground and other terminals | Power switch off | 10 kΩ or more |
| z24-10 (GC1) - Body ground and other terminals | Power switch off | 10 kΩ or more |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| z24-13 (TB0) - Body ground | Power switch on (IG) | 1 V or less |
| z24-1 (GB0) - Body ground | Power switch on (IG) | 1 V or less |
| z24-14 (TB1) - Body ground | Power switch on (IG) | 1 V or less |
| z24-2 (GB1) - Body ground | Power switch on (IG) | 1 V or less |
| z24-15 (TB2) - Body ground | Power switch on (IG) | 1 V or less |
| z24-3 (GB2) - Body ground | Power switch on (IG) | 1 V or less |
| z24-16 (TB3) - Body ground | Power switch on (IG) | 1 V or less |
| z24-4 (GB3) - Body ground | Power switch on (IG) | 1 V or less |
| z24-17 (TB4) - Body ground | Power switch on (IG) | 1 V or less |
| z24-5 (GB4) - Body ground | Power switch on (IG) | 1 V or less |
| z24-18 (TB5) - Body ground | Power switch on (IG) | 1 V or less |
| z24-6 (GB5) - Body ground | Power switch on (IG) | 1 V or less |
| z24-21 (TC0) - Body ground | Power switch on (IG) | 1 V or less |
| z24-9 (GC0) - Body ground | Power switch on (IG) | 1 V or less |
| z24-22 (TC1) - Body ground | Power switch on (IG) | 1 V or less |
| z24-10 (GC1) - Body ground | Power switch on (IG) | 1 V or less |
If the power switch is turned on (IG) with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the z24 battery smart unit connector.
Install the No. 1 hybrid battery shield sub-assembly.
OK
NG