Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)

AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > PROBLEM SYMPTOMS TABLE

for Preparation Click here


HINT:
  1. Use the table below to help determine the cause of the problem symptom. The potential causes of the symptoms are listed in order of probability in the "Suspected area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.
  2. Inspect the fuses and relays related to this system before inspecting the suspected areas below.


Air Conditioning System 
Symptom
Suspected Area
See page
No functions of A/C system operate
1. ECU-IG2 fuse
-
2. Wire harness or connector
-
3. Air conditioning amplifier
Click here
Airflow Control: Blower motor does not operate
1. HTR, ECU-IG1 fuse
-
2. Blower motor circuit
Click here
3. Blower motor
Click here
4. Wire harness or connector
-
Airflow Control: Blower motor does not change speed
1. Blower resistor
Click here
2. Blower motor
Click here
3. Heater control (blower switch)
Click here
Temperature Control: No cool air comes out
1. Refrigerant volume
Click here
2. Refrigerant pressure
Click here
3. Air conditioning pressure sensor circuit
Click here
4. Heater control base
Click here
5. Air mix control knob
Click here
6. Compressor circuit (for 2GR-FE)
Click here
7. Compressor lock sensor circuit (for 2GR-FE)
Click here
8. Compressor solenoid circuit
Click here
9. Expansion valve
Click here
10. Air conditioning amplifier
Click here
11. ECM (for 1AZ-FE)
Click here
12. ECM (for 2AZ-FE)
Click here
13. ECM (for 2GR-FE)
Click here
14. ECM (for 3ZR-FAE)
Click here
15. CAN communication
Click here
Temperature Control: No warm air comes out
1. Evaporator temperature sensor circuit
Click here
2. Ambient temperature sensor circuit
Click here
3. Engine coolant temperature sensor circuit (for 1AZ-FE)
Click here
4. Engine coolant temperature sensor circuit (for 2AZ-FE)
Click here
5. Engine coolant temperature sensor circuit (for 2GR-FE)
Click here
6. Engine coolant temperature sensor circuit (for 3ZR-FAE)
Click here
7. CAN communication system
Click here
8. Air mix damper control cable
Click here
9. Air mix control knob
Click here
10. Air conditioning amplifier
Click here
11. ECM (for 1AZ-FE)
Click here
12. ECM (for 2AZ-FE)
Click here
13. ECM (for 2GR-FE)
Click here
14. ECM (for 3ZR-FAE)
Click here
Compressor and pulley do not operate
1. ECU-IG2 fuse
-
2. Refrigerant pressure
Click here
3. Compressor circuit (for 2GR-FE)
Click here
4. Compressor lock sensor circuit (for 2GR-FE)
Click here
5. Compressor solenoid circuit
Click here
6. Air conditioning pressure sensor circuit
Click here
7. Evaporator temperature sensor circuit
Click here
8. Heater control base
Click here
9. Air mix control knob
Click here
10. Air conditioning amplifier
Click here
11. ECM (for 1AZ-FE)
Click here
12. ECM (for 2AZ-FE)
Click here
13. ECM (for 2GR-FE)
Click here
14. ECM (for 3ZR-FAE)
Click here
15. CAN communication
Click here