CAN COMMUNICATION SYSTEM > Short to GND in CAN Bus Line |
| Symptom | Trouble Area |
| There is resistance between terminals 6 (CANH) and 16 (BAT) or terminals 14 (CANL) and 16 (BAT) of DLC3. |
|


| 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
| NEXT | |
| 2.CHECK FOR SHORT TO GND IN CAN BUS WIRE (DLC3 BRANCH WIRE) |
![]() |
Disconnect the H93 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H19-6 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H19-14 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 3.CONNECT CONNECTOR |
Reconnect the H93 No. 1 junction connector.
| NEXT | |
| 4.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR SIDE) |
![]() |
Disconnect the H100 No. 2 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H19-6 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H19-14 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 5.CONNECT CONNECTOR |
Reconnect the H100 No. 2 junction connector.
| NEXT | |
| 6.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the H92 No. 2 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H92-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H92-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 7.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - BUS BUFFER ECU) |
![]() |
Disconnect the H105 No. 2 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H105-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H105-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 8.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - 4WD CONTROL ECU) |
![]() |
Disconnect the H95 No. 2 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H95-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H95-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 9.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 2 JUNCTION CONNECTOR - ECM) |
![]() |
Disconnect the H99 No. 2 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H99-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H99-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 10.CHECK FOR SHORT TO GND IN CAN BUS WIRE (AIR CONDITIONING AMPLIFIER) |
![]() |
Disconnect the H24 air conditioning amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H92-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H92-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 11.CHECK FOR SHORT TO GND IN CAN BUS WIRE (BUS BUFFER ECU) |
![]() |
Disconnect the H66 bus buffer ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H105-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H105-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 12.CHECK FOR SHORT TO GND IN CAN BUS WIRE (4WD CONTROL ECU) |
![]() |
Disconnect the A28 4WD control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H95-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H95-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 13.CHECK FOR SHORT TO GND IN CAN BUS WIRE (ECM) |
![]() |
Disconnect the A27 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H99-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H99-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| Result | Proceed to |
| NG | A |
| OK (for 2UZ-FE) | B |
| OK (for 3UR-FE) | C |
| OK (for 3UR-FBE) | D |
|
| ||||
|
| ||||
|
| ||||
| A | ||
| ||
| 14.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - NO. 2 JUNCTION CONNECTOR) |
![]() |
Disconnect the H101 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H101-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H101-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 15.CONNECT CONNECTOR |
Reconnect the H101 No. 1 junction connector.
Reconnect the H100 No. 2 junction connector.
| NEXT | |
| 16.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR SIDE) |
![]() |
Disconnect the O41 No. 4 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H19-6 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H19-14 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 17.CONNECT CONNECTOR |
Reconnect the O41 No. 4 junction connector.
| NEXT | |
| 18.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR - SUSPENSION CONTROL ECU) |
![]() |
Disconnect the O42 No. 4 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O42-6 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| O42-12 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 19.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 4 JUNCTION CONNECTOR - COMBINATION METER ECU) |
![]() |
Disconnect the O41 No. 4 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O41-2 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| O41-8 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 20.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - NO. 4 JUNCTION CONNECTOR) |
![]() |
Disconnect the H91 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H91-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H91-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 21.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - COMBINATION METER ECU) |
![]() |
Disconnect the H91 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H91-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H91-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 22.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - POWER STEERING ECU) |
![]() |
Disconnect the H106 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H106-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H106-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 23.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - DISTANCE CONTROL ECU) |
![]() |
Disconnect the A60 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A60-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| A60-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 24.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - MAIN BODY ECU) |
![]() |
Disconnect the H103 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H103-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H103-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 25.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - SKID CONTROL ECU) |
![]() |
Disconnect the A59 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A59-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| A59-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 26.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - STEERING ANGLE SENSOR) |
![]() |
Disconnect the H94 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H94-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H94-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | |
| 27.CHECK FOR SHORT TO GND IN CAN BUS WIRE (NO. 1 JUNCTION CONNECTOR - CENTER AIRBAG SENSOR) |
![]() |
Disconnect the H90 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H90-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H90-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 28.CHECK FOR SHORT TO GND IN CAN BUS WIRE (SUSPENSION CONTROL ECU) |
![]() |
w/ AVS
Disconnect the O18 suspension control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O42-6 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| O42-12 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
w/o AVS
Disconnect the O19 suspension control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O42-6 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| O42-12 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 29.CHECK FOR SHORT TO GND IN CAN BUS WIRE (COMBINATION METER ECU) |
![]() |
Disconnect the H37 combination meter ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H37-33 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H37-34 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 30.CHECK FOR SHORT TO GND IN CAN BUS WIRE (POWER STEERING ECU) |
![]() |
Disconnect the H38 power steering ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H106-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H106-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 31.CHECK FOR SHORT TO GND IN CAN BUS WIRE (DISTANCE CONTROL ECU) |
![]() |
Disconnect the A43 distance control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A60-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| A60-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 32.CHECK FOR SHORT TO GND IN CAN BUS WIRE (MAIN BODY ECU) |
![]() |
Disconnect the H2 main body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H103-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H103-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 33.CHECK FOR SHORT TO GND IN CAN BUS WIRE (SKID CONTROL ECU) |
![]() |
Disconnect the A19 skid control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A59-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| A59-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 34.CHECK FOR SHORT TO GND IN CAN BUS WIRE (STEERING ANGLE SENSOR) |
![]() |
Disconnect the H6 steering angle sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H94-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H94-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||
| 35.CHECK FOR SHORT TO GND IN CAN BUS WIRE (CENTER AIRBAG SENSOR) |
![]() |
Disconnect the H56 center airbag sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H90-1 (CANH) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
| H90-2 (CANL) - H19-4 (CG) | Ignition switch off | 200 Ω or higher |
|
| ||||
| OK | ||
| ||