Home › Engine / Hybrid System › 3UR-FE COOLING › WATER PUMP
RM27M0U _51 Engine / Hybrid System _049112 3UR-FE COOLING _0234058 WATER PUMP A

3UR-FE COOLING  WATER PUMP  INSTALLATION  


PROCEDURE

Hide 16100 1.INSTALL WATER PUMP ASSEMBLY

a.
A151828E03
1.938,0.042 2.052,0.188 0.115,0.146 10 false A 1.438,0.031 1.583,0.188 0.146,0.156 10 true A 2.542,1.51 2.76,1.698 0.219,0.188 10 true B 2.354,0.031 2.583,0.229 0.229,0.198 10 false C 2.99,1.313 3.177,1.531 0.188,0.219 10 false C 2.229,1.969 2.417,2.177 0.188,0.208 10 true C 0.281,0.823 0.438,0.99 0.156,0.167 10 false C 0.677,1.875 0.833,2.063 0.156,0.188 10 true C

Install a new gasket and the water pump with the 8 bolts shown in the illustration.

Torque:
for bolt A : 47 N*m (479 kgf*cm, 35 ft.*lbf)
for bolt B : 23 N*m (235 kgf*cm, 17 ft.*lbf)
for bolt C : 20 N*m (204 kgf*cm, 15 ft.*lbf)


Hide 16173 2.INSTALL WATER PUMP PULLEY

a.
A151837E02
0.347,1.797 0.636,1.946 0.289,0.149 10 SST 1.497,1.654 0.848,1.887 0.848,1.887 0.742,1.887 false

Temporarily install the pulley with the 4 bolts.


b.

Using SST, hold the pulley and tighten the 4 bolts.

SST
09960-10010  (09962-01000, 09963-01000)

Torque:
21 N*m (214 kgf*cm, 15 ft.*lbf)


Hide 16323 3.INSTALL WATER INLET HOUSING

a.

Install a new gasket to the water pump.


b.
A151859E05
0.813,2.219 1.406,2.719 1.406,2.719 1.406,2.927 false 1.719,0.865 2.083,1.01 0.365,0.146 10 false Front 1.146,1.052 1.49,1.198 0.344,0.146 10 false 45° 0.365,0.427 0.906,0.573 0.542,0.146 10 false RH Side 0.542,2.948 2.281,3.219 1.74,0.271 10 true No. 3 Water By-pass Hose

Install the No. 3 water by-pass hose and water inlet housing with the 3 bolts.

Torque:
21 N*m (214 kgf*cm, 15 ft.*lbf)

HINT:

Install the hose so that the direction of the hose clamp is as indicated in the illustration.



c.
A151858E01
0.494,2.555 1.038,2.704 0.544,0.149 10 RH Side 1.214,2.896 1.564,3.045 0.350,0.149 10 Front

Install the air tube bracket bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


d.

Connect the No. 5 water by-pass hose.

HINT:

Install the hose so that the direction of the hose clamp is as indicated in the illustration.



e.
A158575E07
0.792,0.135 0.625,0.135 0.625,0.135 0.385,1.01 false 1.375,1.917 2.135,1.542 2.135,1.542 2.385,1.542 false 2.427,1.448 3.135,1.656 0.708,0.208 10 true No. 2 Hose 0.813,0.052 1.573,0.26 0.76,0.208 10 true No. 3 Hose

Connect the air pump connector clamp's holder.


f.

Attach the wire harness clamp.


g.

Connect the air pump connector.


h.

Connect the No. 2 and No. 3 air hoses.


Hide 16268L 4.CONNECT WATER BY-PASS PIPE (w/ Oil Cooler)

A380083E01
0.854,0.833 1.625,1.031 0.771,0.198 10 false Front 1.854,0.396 2.625,0.594 0.771,0.198 10 false Upper

a.

Connect the water by-pass pipe with water hose.

HINT:

Install the hose so that the direction of the hose clamp is as indicated in the illustration.



b.

Install the 3 bolts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


c.

Connect the No. 6 water by-pass hose.


Hide 16571 7.CONNECT INLET RADIATOR HOSE

Hide 16572 8.CONNECT OUTLET RADIATOR HOSE

Hide 17880 10.INSTALL AIR CLEANER HOSE ASSEMBLY

Hide 11209 13.INSTALL V-BANK COVER SUB-ASSEMBLY