There may be an open circuit in the CAN main wire and/or the DLC3 branch wire when the resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is 70 Ω or higher.
| Symptom | Trouble Area |
|---|---|
| Resistance between terminals 6 (CANH) and 14 (CANL) of DLC3 is 70 Ω or higher. | ·
CAN main wire and connector ·
No. 1 junction connector ·
No. 2 junction connector ·
ECM ·
Combination meter assembly ·
DLC3 CAN branch wire |
Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
After turning the Ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
NEXT
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).
NEXT
Disconnect the J75 No. 1 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J75-2 (CANH) - J17-6 (CANH) | Ignition switch off | Below 1 Ω |
| J75-13 (CANL) - J17-14 (CANL) | Ignition switch off | Below 1 Ω |
| *a | Rear view of wire harness connector
(to No. 1 Junction Connector) |
| *b | Front view of DLC3 |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J75-1 (CANH) - J75-12 (CANL) | Ignition switch off | 108 to 132 Ω |
| *a | Rear view of wire harness connector
(to No. 1 Junction Connector) |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J75-4 (CANH) - J75-15 (CANL) | Ignition switch off | 108 to 132 Ω |
| *a | Rear view of wire harness connector
(to No. 1 Junction Connector) |
OK
NG
Reconnect the J75 No. 1 junction connector.
NEXT
Disconnect the J74 No. 2 junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J74-3 (CANH) - J74-14 (CANL) | Ignition switch off | 108 to 132 Ω |
| *a | Rear view of wire harness connector
(to No. 2 Junction Connector) |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J74-4 (CANH) - J74-15 (CANL) | Ignition switch off | 108 to 132 Ω |
| *a | Rear view of wire harness connector
(to No. 2 Junction Connector) |
OK
NG
Reconnect the J74 No. 2 junction connector.
NEXT
Disconnect the A24 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A24-10 (CANH) - A24-11 (CANL) | Ignition switch off | 108 to 132 Ω |
| *a | Front view of wire harness connector
(to ECM) |
| Result | Proceed to |
|---|---|
| OK (for 1UR-FE) | A |
| OK (for 3UR-FE) | B |
| OK (for 3UR-FBE) | C |
| NG | D |
A
B
C
D
Reconnect the J75 No. 1 junction connector.
NEXT
Disconnect the J28 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J28-39 (CANH) - J28-40 (CANL) | Ignition switch off | 108 to 132 Ω |
| *a | Rear view of wire harness connector
(to Combination Meter Assembly) |
OK
NG