Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System with Side-mounted Air Conditioner Pressure Sensor) › 2016.10–2019.09
RM32H0E _58 Vehicle Interior _059841 HEATING / AIR CONDITIONING _0298708 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System with Side-mounted Air Conditioner Pressure Sensor) S

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System with Side-mounted Air Conditioner Pressure Sensor)  DIAGNOSTIC TROUBLE CODE CHART  


AIR CONDITIONING SYSTEM
DTC No. Detection Item DTC Detection Condition Link
B1411 Room Temperature Sensor Circuit Any of the following conditions is met:
·

Open in cooler thermistor (room temperature sensor) circuit

·

Short in cooler thermistor (room temperature sensor) circuit


Click here
B1412 Ambient Temperature Sensor Circuit When the air conditioning amplifier assembly cannot receive outside temperature sensor data from the combination meter assembly. Click here
B1413 Evaporator Temperature Sensor Circuit Any of the following conditions is met:
·

Open in No. 1 cooler thermistor (evaporator temperature sensor) circuit

·

Short in No. 1 cooler thermistor (evaporator temperature sensor) circuit


Click here
B1423 Pressure Sensor Circuit
·

Open in air conditioner pressure sensor circuit

·

Short in air conditioner pressure sensor circuit

·

for HFC-134a (R134a): Refrigerant pressure on high pressure side is extremely low (0.176 MPaG (1.8 kgf/cm2, 26 psi) or less) or extremely high (3.025 MPaG (30.8 kgf/cm2, 439 psi) or more)

·

for HFO-1234yf (R1234yf): Refrigerant pressure on high pressure side is extremely low (0.195 MPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2.812 MPaG (28.7 kgf/cm2, 408 psi) or more)


Click here
B1441 Air Mix Damper Control Servo Motor Circuit (Passenger Side) Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly Click here
B1442 Air Inlet Damper Control Servo Motor Circuit Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly Click here
B1443 Air Outlet Damper Control Servo Motor Circuit Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly Click here
B1446 Air Mix Damper Control Servo Motor Circuit (Driver Side) Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly Click here
B1451 Compressor Solenoid Circuit Any of the following conditions is met:
·

Open in compressor solenoid circuit

·

Short in compressor solenoid circuit


Click here
B1497 Communication Malfunction (Bus Ic) Any of the following conditions is met:
·

Error in communication line

·

Open in communication line


Click here
B14B2 Lost Communication with Front Panel LIN Lost communication with air conditioning control assembly Click here
B14B8 Refrigerant Shortage When following condition is detected in refrigerant shortage check in normal operation:
Amount of refrigerant is insufficient
Click here
B14B9 Open in Ion Generator Circuit Open in ion generator sub-assembly circuit Click here
U0100 Lost Communication with ECM No communication with ECM Click here
U0131 Lost Communication with Electric Power Steering ECU No communication with power steering ECU assembly Click here
U0142 Lost Communication with Main Body ECU No communication with main body ECU (multiplex network body ECU) Click here
U0155 Lost Communication with Combination Meter No communication with combination meter assembly Click here