| B1411
|
Room Temperature Sensor Circuit
|
Any of the following conditions is met:
·
Open in cooler thermistor (room temperature sensor) circuit
·
Short in cooler thermistor (room temperature sensor) circuit
|
|
| B1412
|
Ambient Temperature Sensor Circuit
|
When the air conditioning amplifier assembly cannot receive outside temperature sensor data from the combination meter assembly.
|
|
| B1413
|
Evaporator Temperature Sensor Circuit
|
Any of the following conditions is met:
·
Open in No. 1 cooler thermistor (evaporator temperature sensor) circuit
·
Short in No. 1 cooler thermistor (evaporator temperature sensor) circuit
|
|
| B1423
|
Pressure Sensor Circuit
|
·
Open in air conditioner pressure sensor circuit
·
Short in air conditioner pressure sensor circuit
·
for HFC-134a (R134a): Refrigerant pressure on high pressure side is extremely low (0.176 MPaG (1.8 kgf/cm2, 26 psi) or less) or extremely high (3.025 MPaG (30.8 kgf/cm2, 439 psi) or more)
·
for HFO-1234yf (R1234yf): Refrigerant pressure on high pressure side is extremely low (0.195 MPaG (2.0 kgf/cm2, 28 psi) or less) or extremely high (2.812 MPaG (28.7 kgf/cm2, 408 psi) or more)
|
|
| B1441
|
Air Mix Damper Control Servo Motor Circuit (Passenger Side)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly
|
|
| B1442
|
Air Inlet Damper Control Servo Motor Circuit
|
Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly
|
|
| B1443
|
Air Outlet Damper Control Servo Motor Circuit
|
Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly
|
|
| B1446
|
Air Mix Damper Control Servo Motor Circuit (Driver Side)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly
|
|
| B1451
|
Compressor Solenoid Circuit
|
Any of the following conditions is met:
·
Open in compressor solenoid circuit
·
Short in compressor solenoid circuit
|
|
| B1497
|
Communication Malfunction (Bus Ic)
|
Any of the following conditions is met:
·
Error in communication line
·
Open in communication line
|
|
| B14B2
|
Lost Communication with Front Panel LIN
|
Lost communication with air conditioning control assembly
|
|
| B14B8
|
Refrigerant Shortage
|
When following condition is detected in refrigerant shortage check in normal operation:
Amount of refrigerant is insufficient
|
|
| B14B9
|
Open in Ion Generator Circuit
|
Open in ion generator sub-assembly circuit
|
|
| U0100
|
Lost Communication with ECM
|
No communication with ECM
|
|
| U0131
|
Lost Communication with Electric Power Steering ECU
|
No communication with power steering ECU assembly
|
|
| U0142
|
Lost Communication with Main Body ECU
|
No communication with main body ECU (multiplex network body ECU)
|
|
| U0155
|
Lost Communication with Combination Meter
|
No communication with combination meter assembly
|
|