| B1411/11
|
Room Temperature Sensor Circuit
|
Open or short in room temperature sensor (cooler thermistor) circuit
|
|
| B1412/12
|
Ambient Temperature Sensor Circuit
|
Open or short in ambient temperature sensor (thermistor assembly) circuit
|
|
| B1413/13
|
Evaporator Temperature Sensor Circuit
|
Open or short in evaporator temperature sensor (No. 1 cooler thermistor) circuit
|
|
| B1422/22
|
Compressor Lock Sensor Circuit
|
Open or short in A/C lock sensor circuit
|
|
| B1423/23
|
Pressure Sensor Circuit
|
·
Open or short in air conditioning pressure sensor circuit
·
Refrigerant pressure on the high pressure side is extremely low (0.19 MPa (2.0 kgf/cm2, 28 psi) or less) or extremely high (3.14 MPa (32.0 kgf/cm2, 455 psi) or more).
|
|
| B1441/41
|
Air Mix Damper Control Servo Motor Circuit (Passenger Side)
|
for LHD:
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (air mix (for front passenger side))
for RHD:
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 2 air conditioning radiator damper servo sub-assembly (air mix (for front passenger side))
|
|
| B1442/42
|
Air Inlet Damper Control Servo Motor Circuit
|
Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 blower damper servo sub-assembly (air inlet)
|
|
| B1443/43
|
Air Outlet Damper Control Servo Motor Circuit
|
Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (air outlet)
|
|
| B1446/46
|
Air Mix Damper Control Servo Motor Circuit (Driver Side)
|
for LHD:
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 2 air conditioning radiator damper servo sub-assembly (air mix for driver side)
for RHD:
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (air mix for driver side)
|
|
| B1451/51
|
Compressor Solenoid Circuit
|
Open or short in compressor solenoid circuit
|
|
| B1479/79
|
Flow Sensor Circuit
|
Open or short in A/C flow sensor circuit
|
|
| B1497/97
|
BUS IC Communication Malfunction
|
Error or open in communication line
|
|
| B14A2
|
Driver Side Solar Sensor Short Circuit
|
Short in driver side solar sensor (automatic light control sensor) circuit
|
|
| B14A3
|
Front Passenger Side Solar Sensor Short Circuit
|
Short in passenger side solar sensor (automatic light control sensor) circuit
|
|
| B14B2
|
Lost Communication with Front Panel LIN
|
Lost communication with the air conditioning panel (heater control switch board).
|
|
| B14B8
|
Refrigerant Shortage
|
When the following conditions is detected using the refrigerant shortage check in normal operation:
The amount of refrigerant is insufficient.
|
|
| U0100
|
Lost Communication with ECM
|
No communication with ECM
|
|
| U0131
|
Lost Communication with Electric Power Steering ECU
|
No communication with electric power steering ECU
|
|
| U0142
|
Lost Communication with Main Body ECU
|
No communication with main body ECU
|
|
| U0155
|
Lost Communication with Combination Meter
|
No communication with combination meter
|
|