SFI SYSTEM > EVAP System |
| DTC | Monitoring Item | See procedure |
| P043E | 0.02 inch orifice clogged (built into pump module) |
Click here
|
| P043F | 0.02 inch orifice high-flow (built into pump module) | |
| P0441 |
|
Click here
|
| P0450 | Pressure sensor (built into pump module) voltage abnormal fluctuation |
Click here
|
| P0451 |
| |
| P0452 | Pressure sensor (built into pump module) voltage low | |
| P0453 | Pressure sensor (built into pump module) voltage high | |
| P0455 | EVAP gross leak |
Click here
|
| P0456 | EVAP small leak | |
| P2401 | Vacuum pump stuck OFF (built into pump module) |
Click here
|
| P2402 | Vacuum pump stuck ON (built into pump module) | |
| P2419 | Vent valve stuck ON (closed) (built into pump module) | |
| P2420 | Vent valve stuck OFF (vent) (built into pump module) |
Click here
|
| P2610 | Soak timer (built into ECM) |
Click here
|

| KEY-OFF MONITOR CONFIRMATION |
Preconditions
The monitor will not run unless:
The vehicle has been driven for 10 minutes or more (in a city area or on a freeway)
The fuel tank is less than 90% full
The altitude is less than 8000 ft. (2400 m)
The Engine Coolant Temperature (ECT) is between 4.4°C and 35°C (40°F and 95°F)
The Intake Air Temperature (IAT) is between 4.4°C and 35°C (40°F and 95°F)
The vehicle remains stationary (the vehicle speed is 0 mph [0 km/h])
Monitor Conditions
Allow the engine to idle for at least 5 minutes.
Turn the ignition switch off and wait for 6 hours (8 or 10.5 hours).
Monitor Status
Connect the Techstream to the DLC3.
Turn the ignition switch on (IG) and turn the tester on.
Select the following menu items: Powertrain / Engine and ECT / Monitor / Evaporative System.
Check the "Monitor Status" displayed on the tester.
| PURGE FLOW MONITOR CONFIRMATION (P0441) |
Preconditions
The monitor will not run unless:
Monitor Conditions
Release the pressure from the fuel tank by removing and reinstalling the fuel tank cap.
Warm the engine up until the ECT reaches more than 75°C (167°F).
Increase the engine speed to 3000 rpm once.
Allow the engine to idle and turn the A/C ON for 1 minute.
Monitor Status
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch on (IG) and turn the tester on.
Select the following menu items: Powertrain / Engine and ECT / Monitor.
Check the "Monitor Status" displayed on the tester.
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
| $3D | $C9 | Multiply by 0.01 [kPa] | Test value for small leak (P0456) Refer to pressure D* | Minimum test limit for small leak | Maximum test limit for small leak |
| $3D | $CA | Multiply by 0.01 [kPa] | Test value for gross leak (P0455) Refer to pressure E* | Minimum test limit for gross leak | Maximum test limit for gross leak |
| $3D | $CB | Multiply by 0.01 [kPa] | Test value for vacuum pump stuck OFF (P2401) Refer to pressure A* | Minimum test limit for vacuum pump stuck OFF | Maximum test limit for vacuum pump stuck OFF |
| $3D | $CD | Multiply by 0.01 [kPa] | Test value for vacuum pump stuck ON (P2402) Refer to pressure A* | Minimum test limit for vacuum pump stuck ON | Maximum test limit for vacuum pump stuck ON |
| $3D | $CE | Multiply by 0.01 [kPa] | Test value for vent valve stuck OFF (vent) (P2420) Refer to pressure C* | Minimum test limit for vent valve stuck ON | Maximum test limit for vent valve stuck ON |
| $3D | $CF | Multiply by 0.01 [kPa] | Test value for vent valve stuck ON (P2419) Refer to pressure A* | Minimum test limit for vent valve stuck OFF | Maximum test limit for vent valve stuck OFF |
| $3D | $D0 | Multiply by 0.01 [kPa] | Test value for 0.02 inch orifice low flow (P043E) Refer to pressure B* | Minimum test limit for 0.02 inch orifice low flow | Maximum test limit for 0.02 inch orifice low flow |
| $3D | $D1 | Multiply by 0.01 [kPa] | Test value for 0.02 inch orifice high flow (P043F) Refer to pressure A* | Minimum test limit for 0.02 inch orifice high flow | Maximum test limit for 0.02 inch orifice high flow |
| $3D | $D4 | Multiply by 0.01 [kPa] | Test value for purge VSV stuck closed (P0441) Refer to pressure F* | Minimum test limit for purge VSV stuck closed | Maximum test limit for purge VSV stuck closed |
| $3D | $D5 | Multiply by 0.01 [kPa] | Test value for purge VSV stuck open (P0441) Refer to pressure E* | Minimum test limit for purge VSV stuck open | Maximum test limit for purge VSV stuck open |
| $3D | $D7 | Multiply by 0.01 [kPa] | Test value for purge flow (P0441) Refer to pressure G* | Minimum test limit for purge flow | Maximum test limit for purge flow |



| Key-off monitor |
| Purge flow monitor |

| Component | Operation |
| Canister | Contains activated charcoal to absorb EVAP (Evaporative Emissions) generated in fuel tank. |
| Cut-off valve | Located in fuel tank. Valve floats and closes when fuel tank is 100% full. |
| Purge VSV (Vacuum Switching Valve) | Opens or closes line between canister and intake manifold. ECM uses purge VSV to control EVAP purge flow. In order to discharge EVAP absorbed by canister to intake manifold, ECM opens purge VSV. EVAP discharge volume to intake manifold is controlled by purge VSV duty cycle ratio (current-carrying time). (Open: ON, Close: OFF) |
| Refueling valve | Controls EVAP pressure from fuel tank to canister. Valve consists of diaphragm, spring and restrictor (diameter: 0.08 inch). When fuel vapor and pressure inside fuel tank increase, valve opens. While EVAP is purged, valve closes and restrictor prevents a large amount of vacuum from affecting pressure in fuel tank. Valve is opened while refueling. When valve is open, adding fuel into fuel tank is possible. |
| Roll-over valve | Located in fuel tank. Valve closes by its own weight when vehicle overturns to prevent fuel from spilling out. |
| Service port | Used for connecting vacuum gauge for inspecting EVAP system. |
| Soak timer | Built into ECM. To ensure accurate EVAP monitor, measures 5 hours (+/- 15 min.) after ignition switch is turned off. This allows fuel to cool down, stabilizing Fuel Tank Pressure (FTP). When approx. 5 hours elapsed, ECM activates. |
| Canister pump module | Consists of (a) to (d) below. Pump module cannot be disassembled. |
| (a) Vent valve | Vents and closes EVAP system. When ECM turns valve ON, EVAP system is closed. When ECM turns valve OFF, EVAP system is vented. Negative pressure (vacuum) is created in EVAP system to check for EVAP leaks by closing purge VSV and vent valve (closed), and operating vacuum pump are turned on (refer to fig. 1). |
| (b) Canister pressure sensor | Indicates pressure as voltages. ECM supplies regulated 5 V to pressure sensor, and uses feedback from sensor to monitor EVAP system pressure (refer to fig 2). |
| (c) Vacuum pump | Creates negative pressure (vacuum) in EVAP system for leak check. |
| (d) 0.02 inch orifice | Has an opening with 0.02 inch diameter. Vacuum is produced through orifice by closing purge VSV, turning off vent valve and operating vacuum pump, to monitor 0.02 inch leak pressure. 0.02 inch leak pressure indicates a small leak of EVAP. |



| 1.CONFIRM DTC |
Turn the ignition switch off and wait for 10 seconds.
Turn the ignition switch on (IG).
Turn the ignition switch off and wait for 10 seconds.
Connect the Techstream to the DLC3.
Turn the ignition switch on (IG) and turn the tester on.
Select the following menus: Powertrain / Engine and ECT / Trouble Codes.
Confirm DTCs and freeze frame data.
If any EVAP system DTCs are set, the malfunctioning area can be determined using the table below.

| NEXT | |
| 2.PERFORM EVAP SYSTEM CHECK (AUTO OPERATION) |
Connect the Techstream to the DLC3.
Clear the DTCs (Click here).
Select the following menu items on the tester: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.
After the Evaporative System Check is completed, check for pending DTCs by selecting the following menu items: Powertrain / Engine and ECT / Trouble Codes / Pending.
| NEXT | |
| 3.PERFORM EVAP SYSTEM CHECK (MANUAL OPERATION) |

Connect the Techstream to the DLC3.
Clear the DTCs (Click here).
Select the following menu items: Powertrain / Engine and ECT / Utility / Evaporative System Check / Manual Mode.
| NEXT | |
| 4.PERFORM EVAP SYSTEM CHECK (STEP 1/5) |

Check the EVAP pressure in step 1/5.
| DTC* | Result | Suspected Trouble Area | Proceed to |
| - | Virtually no variation in EVAP pressure | Not yet determined | A |
| P0451 | EVAP pressure fluctuates by +/-0.3 kPa (2.25 mmHg) or more | Pressure sensor noising | B |
|
| ||||
| A | |
| 5.PERFORM EVAP SYSTEM CHECK (STEP 1/5 TO 2/5) |

Check the EVAP pressure in steps 1/5 and 2/5.
| DTC* | Result | Suspected Trouble Area | Proceed to |
| - | Virtually no variation in EVAP pressure during step 1/5. Then decreases to 0.02 inch leak pressure standard* | Not yet determined | A |
| P2402 | Small difference between EVAP pressures during steps 1/5 and 2/5 | Vacuum pump stuck ON | B |
|
| ||||
| A | |
| 6.PERFORM EVAP SYSTEM CHECK (STEP 2/5) |

Check the EVAP pressure 4 seconds after the vacuum pump is activated*1 (Step (a)).
Check the EVAP pressure again when it has stabilized. This pressure is the 0.02 inch leak pressure standard (Step (b)).
*1: The vacuum pump begins to operate at the time step 2/5 starts.
| DTC*2 | Result | Suspected Trouble Area | Proceed to |
| - | EVAP pressure in step (b) is between -4.85 kPa and -1.06 kPa (-36.38 mmHg and -7.95 mmHg) | Not yet determined | A |
| P043F and P2401 | EVAP pressure in step (b) is -1.06 kPa (-7.95 mmHg) or more |
| B |
| P043E | EVAP pressure in step (b) is less than -4.85 kPa (-36.38 mmHg) | 0.02 inch orifice clogged | C |
| P2419 | EVAP pressure in step (a) is more than -1.06 kPa (-7.95 mmHg) | Vent valve stuck closed | D |
|
| ||||
|
| ||||
|
| ||||
| A | |
| 7.PERFORM EVAP SYSTEM CHECK (STEP 2/5 TO 3/5) |

Check the EVAP pressure increase in step 3/5.
| DTC* | Result | Suspected Trouble Area | Proceed to |
| - | EVAP pressure increases by 0.3 kPa (2.25 mmHg) or more within 10 seconds of proceeding from step 2/5 to step 3/5 | Not yet determined | A |
| P2420 | No variation in EVAP pressure even after proceeding from step 2/5 to step 3/5 | Vent valve stuck open (vent) | B |
| P0451 | No variation in EVAP pressure during steps 1/5 through 3/5 | Pressure sensor malfunction | C |
|
| ||||
|
| ||||
| A | |
| 8.PERFORM EVAP SYSTEM CHECK (STEP 3/5) |

Wait until the EVAP pressure change is less than 0.1 kPa (0.75 mmHg) for 30 seconds.
Measure the EVAP pressure and record it.
| NEXT | |
| 9.PERFORM EVAP SYSTEM CHECK (STEP 4/5) |

Check the EVAP pressure in step 4/5.
| DTC* | Result | Suspected Trouble Area | Proceed to |
| - | EVAP pressure increases by 0.3 kPa (2.25 mmHg) or more within 10 seconds of proceeding from step 3/5 to step 4/5 | Not yet determined | A |
| P0441 | EVAP pressure increases by 0.3 kPa (2.25 mmHg) or more within 10 seconds of proceeding from step 3/5 to step 4/5 | Problems in EVAP hose between purge VSV and intake manifold | B |
| P0441 | Variation in EVAP pressure is less than 0.3 kPa (2.25 mmHg) for 10 seconds, after proceeding from step 3/5 to step 4/5 | Purge VSV stuck closed | C |
|
| ||||
|
| ||||
| A | |
| 10.PERFORM EVAP SYSTEM CHECK (STEP 5/5) |

Check the EVAP pressure in step 5/5.
Compare the EVAP pressure in step 3/5 and the second 0.02 inch leak pressure standard (step 5/5).
| DTC* | Result | Suspected Trouble Area | Proceed to |
| - | EVAP pressure (step 3/5) lower than second 0.02 inch leak pressure standard (step 5/5) | Not yet determined (no leakage from EVAP system) | A |
| P0441 and P0455 | EVAP pressure (step 3/5) higher than [second 0.02 inch leak pressure standard (step 5/5) x 0.2] |
| B |
| P0456 | EVAP pressure (step 3/5) higher than second 0.02 inch leak pressure standard (step 5/5) | EVAP small leak | B |
|
| ||||
|
| ||||
| 11.PERFORM EVAP SYSTEM CHECK (STEP 3/5) |

Check the EVAP pressure in step 3/5.
| DTC* | Result | Suspected Trouble Area | Proceed to |
| P043F | EVAP pressure is less than [0.02 inch leak pressure standard] measured in step 2/5 | 0.02 inch orifice high-flow | A |
| P2401 | EVAP pressure is almost the same as [0.02 inch leak pressure standard] measured in step 2/5 | Vacuum pump stuck OFF | B |
|
| ||||
|
| ||||
| 12.PERFORM ACTIVE TEST USING TECHSTREAM (PURGE VSV) |
![]() |
Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Activate the VSV for EVAP Control.
Disconnect the hose (connected to the canister) from the purge VSV.
Start the engine.
Using the tester, turn off the purge VSV (EVAP VSV: OFF).
Confirm that the purge VSV has no suction with your fingers.
Using the tester, turn on the purge VSV (EVAP VSV: ON).
Confirm that the purge VSV has suction with your fingers.
| Result | Suspected Trouble Area | Proceed to |
| No suction when purge VSV turned OFF, and suction applied when turned ON | - | A |
| Suction applied when purge VSV turned OFF | Purge VSV stuck open | B |
| No suction when purge VSV turned ON |
| C |
Reconnect the hose.
|
| ||||
|
| ||||
| A | |
| 13.CHECK FUEL TANK CAP ASSEMBLY |
Check that the fuel tank cap is correctly installed and confirm the fuel tank cap meets OEM specification.
Tighten the fuel tank cap.
Remove the fuel tank cap and install it onto the fuel tank cap adaptor.
Connect the EVAP tester pump hose to the adaptor, and pressurize the cap to 3.2 to 3.7 kPa (24 to 28 mmHg) using an EVAP tester pump.
Seal the adaptor and wait for 2 minutes.
Check the pressure. If the pressure is 2 kPa (15 mmHg) or more, the fuel tank cap is normal.
| Test Result | Suspected Trouble Area | Proceed to |
| Fuel tank cap correctly installed | - | A |
| Fuel tank cap loose |
| B |
| No fuel tank cap | - | C |
|
| ||||
|
| ||||
|
| ||||
| 14.INSPECT PURGE VSV |
![]() |
Turn the ignition switch off.
Disconnect the purge VSV connector.
Disconnect the hose (connected to the canister) from the purge VSV.
Start the engine.
Confirm that the purge VSV has no suction with your fingers.
| Result | Suspected Trouble Area | Proceed to |
| No suction | ECM | A |
| Suction applied | Purge VSV | B |
Reconnect the purge VSV connector.
Reconnect the hose.
|
| ||||
|
| ||||
| 15.CHECK EVAP HOSE (PURGE VSV - THROTTLE BODY) |
![]() |
Disconnect the hose (connected to the throttle body) from the purge VSV.
Start the engine.
Confirm that the hose has suction with your fingers.
| Result | Suspected Trouble Area | Proceed to |
| Suction applied | - | A |
| No suction |
| B |
Reconnect the hose.
|
| ||||
| A | |
| 16.INSPECT VACUUM SWITCHING VALVE NO. 1 (PURGE VSV) |
![]() |
Remove the purge VSV.
Apply battery voltage to the terminals of the purge VSV.
Using compressed air, confirm that air flows from port A to port B.
| Result | Suspected Trouble Area | Proceed to |
| Air flows | - | A |
| No air flow | Purge VSV | B |
Install the purge VSV.
|
| ||||
| A | |
| 17.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF PURGE VSV) |
![]() |
Disconnect the purge VSV connector.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 - 2 | Ignition switch on (IG) | 9 to 14 V |
| Result | Suspected Trouble Area | Proceed to |
| Between 9 V and 14 V | - | A |
| Other than result above | Wire harness or connectors between purge VSV and ECM | B |
Reconnect the purge VSV connector.
|
| ||||
| A | |
| 18.CHECK HARNESS AND CONNECTOR (PURGE VSV - ECM) |
![]() |
Disconnect the ECM connector and the purge VSV connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| B1-34 (PRG) - B29-2 | Below 1 Ω |
| B1-34 (PRG) - Body ground | 10 kΩ or higher |
| B29-1 - Body ground | 10 kΩ or higher |
Reconnect the purge VSV connector.
Reconnect the ECM connector.
|
| ||||
|
| ||||
| 19.PERFORM ACTIVE TEST USING TECHSTREAM (FOR VENT VALVE) |
![]() |
Turn the ignition switch on (IG).
Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Activate the VSV for Vent Valve.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D35-5 (VPMP) - Body ground | Vent valve ON | 9 to 14 V |
| Vent valve OFF | Below 3 V |
| Result | Suspected Trouble Area | Proceed to |
| Between 9 V and 14 V when OFF Below 3 V when ON | Vent valve | A |
| Below 3 V when OFF and ON | ECM | B |
|
| ||||
|
| ||||
| 20.PERFORM ACTIVE TEST USING TECHSTREAM (FOR VENT VALVE) |
![]() |
Turn the ignition switch on (IG).
Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Activate the VSV for Vent Valve.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D35-5 (VPMP) - Body ground | Vent valve ON | 9 to 14 V |
| Vent valve OFF | Below 3 V |
| Result | Suspected Trouble Area | Proceed to |
| Below 3 V when OFF and ON | Power source of vent valve | A |
| Between 9 V and 14 V when OFF Below 3 V when ON | Vent valve | B |
| Between 9 V and 14 V when OFF and ON | ECM | C |
|
| ||||
|
| ||||
| A | |
| 21.INSPECT PUMP MODULE (POWER SOURCE FOR VENT VALVE) |
![]() |
Turn the ignition switch off.
Disconnect the canister pomp module connector.
Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| N8-9 - Body ground | Ignition switch on (IG) | 9 to 14 V |
| Test Result | Suspected Trouble Area | Proceed to |
| Between 9 V and 14 V |
| A |
| Between 0 V and 3 V | Power source wire harness of vent valve | B |
Reconnect the canister pomp module connector.
|
| ||||
| A | |
| 22.INSPECT PUMP MODULE (VENT VALVE OPERATION) |
![]() |
Turn the ignition switch off.
Disconnect the canister pomp module connector.
Apply the battery voltage to terminals 9 and 8 of the pump module.
Touch the pump module to confirm the vent valve operation.
| Result | Suspected Trouble Area | Proceed to |
| Operating | Wire harness between vent valve and ECM | A |
| Not operating | Vent valve | B |
Reconnect the canister pomp module connector.
|
| ||||
|
| ||||
| 23.PERFORM ACTIVE TEST USING TECHSTREAM (FOR CANISTER PUMP MODULE (VACUUM PUMP)) |
![]() |
Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Activate the Vacuum Pump.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D35-6 (MPMP) - Body ground | Vacuum Pump ON | 9 to 14 V |
| Test Result | Suspected Trouble Area | Proceed to |
| Between 0 V and 3 V when OFF Between 9 V and 14 V when ON | - | A |
| Between 9 V and 14 V when OFF Between 0 V and 3 V when ON | ECM | B |
|
| ||||
| A | |
| 24.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
![]() |
Turn the ignition switch off.
Disconnect the canister pomp module connector.
Turn the ignition switch on (IG).
Select the following menu items on the tester: Powertrain / Engine and ECT / Active Test / Activate the Vacuum Pump.
Turn the vacuum pump ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| N8-1 - Body ground | Vacuum pump ON | 9 to 14 V |
| Test Result | Suspected Trouble Area | Proceed to |
| Between 9 V and 14 V | - | A |
| Between 0 V and 3 V | Wire harness between ECM and vacuum pump | B |
Reconnect the canister pomp module connector.
|
| ||||
| A | |
| 25.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - BODY GROUND) |
![]() |
Disconnect the canister pomp module connector.
Turn the ignition switch off.
Check the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| N8-6 - Body ground | Always | Below 1 Ω |
| Test Result | Suspected Trouble Area | Proceed to |
| Below 1 Ω | Vacuum Pump | A |
| 10 kΩ or higher | Wire harness between vacuum pump and body ground | B |
Reconnect the canister pomp module connector.
|
| ||||
|
| ||||
| 26.INSPECT THROTTLE BODY |
Stop the engine.
Disconnect the EVAP hose from the throttle body.
Start the engine.
Confirm that the port of the throttle body has suction with your fingers.
| Test Result | Suspected Trouble Area | Proceed to |
| Suction applied | EVAP hose between throttle body and purge VSV | A |
| No suction | Throttle body | B |
Reconnect the EVAP hose.
|
| ||||
|
| ||||
| 27.CORRECTLY REINSTALL OR REPLACE FUEL TANK CAP |
|
| ||||
| 28.REPLACE FUEL TANK CAP ASSEMBLY |
|
| ||||
| 29.LOCATE EVAP LEAK |
Disconnect the vent hose.

Connect the EVAP pressure tester tool to the canister with the adapter.

Pressurize the EVAP system by 3.2 to 3.7 kPa (24 to 28 mmHg).
Apply soapy water to the piping and the connecting parts of the EVAP system.
Look for areas where bubbles appear. This indicates a leak point.
Repair or replace the leak point.
|
| ||||
| 30.REPLACE CHARCOAL CANISTER ASSEMBLY |
Replace the charcoal canister assembly (Click here).

|
| ||||
| 31.REPLACE VACUUM SWITCHING VALVE NO. 1 (PURGE VSV) |
![]() |
Disconnect the connector and 2 hoses from the purge VSV.
Remove the purge VSV.
Install a new purge VSV.
Reconnect the connector and 2 hoses.
|
| ||||
| 32.REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
| ||||
| 33.REPLACE EVAP HOSE (THROTTLE BODY - PURGE VSV) |
|
| ||||
| 34.INSPECT THROTTLE BODY |
Remove the throttle body (Click here).
Check that the EVAP purge port of the throttle body is not clogged. If necessary, replace the throttle body.
|
| ||||
| 35.REPLACE ECM |
Replace the ECM (Click here).
|
| ||||
| 36.REPAIR OR REPLACE PARTS AND COMPONENTS INDICATED BY OUTPUT DTCS |
Repair the malfunctioning areas indicated by the DTCs that had been confirmed when the vehicle was brought in.
| NEXT | |
| 37.PERFORM EVAP SYSTEM CHECK (AUTO OPERATION) |
Clear the DTCs (Click here).
On the Techstream, select the following menu items: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.
After the Evaporative System Check is completed, check for pending DTCs by selecting the following menu items: Powertrain / Engine and ECT / Trouble Codes / Pending.
| NEXT | ||
| ||