| B1411/11
|
Room Temperature Sensor Circuit
|
Open or short in room temperature sensor circuit
|
|
| B1412/12
|
Ambient Temperature Sensor Circuit
|
Open or short in ambient temperature sensor circuit
|
|
| B1413/13
|
Evaporator Temperature Sensor Circuit
|
Open or short in evaporator temperature sensor circuit
|
|
| B1417/17
|
Rear Evaporator Temperature Sensor Circuit
|
Open or short in rear evaporator temperature sensor circuit
|
|
| B1419/19
|
Rear Room Temperature Sensor Circuit
|
Open or short in rear room temperature sensor circuit
|
|
| B1422/22
|
Compressor Lock Sensor Circuit
|
Open or short in A/C lock sensor circuit (for 2GR-FKS)
|
|
| B1423/23
|
Pressure Sensor Circuit
|
·
Open or short in air conditioner tube and accessory assembly circuit
·
Refrigerant pressure on high pressure side is extremely low (176 kPa (1.8 kgf/cm2, 26 psi) or less) or extremely high (3025 kPa (30.8 kgf/cm2, 439 psi) or more)
|
|
| B1441/41
|
Air Mix Damper Control Servo Motor Circuit (Passenger Side)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (air mix for front passenger side) (for LHD) or No. 2 air conditioning radiator damper servo sub-assembly (air mix for front passenger side) (for RHD)
|
|
| B1442/42
|
Air Inlet Damper Control Servo Motor Circuit
|
Air inlet damper position sensor value does not change even if air conditioning amplifier assembly operates blower damper servo sub-assembly (air inlet)
|
|
| B1443/43
|
Air Outlet Damper Control Servo Motor Circuit
|
Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates No. 1 air conditioning radiator damper servo sub-assembly (air outlet)
|
|
| B1446/46
|
Air Mix Damper Control Servo Motor Circuit (Driver Side)
|
Air mix damper position sensor value does not change even if air conditioning amplifier assembly operates No. 2 air conditioning radiator damper servo sub-assembly (air mix for driver side) (for LHD) or No. 1 air conditioning radiator damper servo sub-assembly (air mix for driver side) (for RHD)
|
|
| B1451/51
|
Compressor Solenoid Circuit
|
Open or short in compressor solenoid circuit
|
|
| B1457/57
|
Driver Side Air Outlet Damper Control Servo Motor Circuit
|
Rear air mix damper position sensor value does not change even if air conditioning amplifier assembly operates rear air mix damper servo sub-assembly
|
|
| B1486/86
|
Driver Side Air Outlet Damper Control Servo Motor Circuit
|
Rear air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates rear mode damper servo sub-assembly
|
|
| B1497/97
|
BUS IC Communication Malfunction
|
Error or open in communication line
|
|
| B14B2
|
Lost Communication with Front Panel LIN
|
Lost communication with air conditioning control assembly
|
|
| B14B3
|
Lost Communication with Rear Panel LIN
|
Lost communication with No. 2 air conditioning control assembly
|
|
| B14B8
|
Refrigerant Shortage
|
When following condition is detected in refrigerant shortage check in normal operation:
Amount of refrigerant is insufficient
|
|
| U0100
|
Lost Communication with ECM
|
No communication with ECM
|
|
| U0131
|
Lost Communication with Electric Power Steering ECU
|
No communication with power steering ECU assembly
|
|
| U0142
|
Lost Communication with Main Body ECU
|
No communication with main body ECU (multiplex network body ECU)
|
|
| U0155
|
Lost Communication with Combination Meter
|
No communication with combination meter assembly
|
|