Home › Suspension › SUSPENSION CONTROL › SUSPENSION CONTROL SYSTEM (w/ KDSS)
RM27T0E _53 Suspension _053706 SUSPENSION CONTROL _0260885 SUSPENSION CONTROL SYSTEM(w/ KDSS) N

SUSPENSION CONTROL  SUSPENSION CONTROL SYSTEM(w/ KDSS)  BLEEDING  


PROCEDURE

Hide 1. BLEED AIR FROM SUSPENSION FLUID

CAUTION:
·

Be sure to check the pipe connections and whether or not any hydraulic circuit parts are damaged before performing work as the hydraulic circuits become highly pressurized during air bleeding.

·

The pipes become highly pressurized when bleeding air. If a fluid leak is discovered, immediately release the pressure and repair the fluid leak as there is danger involved.



HINT:

When bleeding air, approximately 6 liters of new fluid is needed.


a.

Remove the stabilizer control valve protector (See page Suspension>SUSPENSION CONTROL>STABILIZER CONTROL TUBE (w/ KDSS)>REMOVAL).


b.

Check the pipe connections and whether or not any hydraulic circuit parts are damaged.

C214861E01
2.989,3.705 3.145,3.858 0.156,0.152 10 *1 3.325,3.966 3.325,3.774 3.325,3.774 3.139,3.774 false 4.086,5.301 4.279,5.454 0.193,0.152 10 *2 3.087,5.293 3.280,5.445 0.193,0.152 10 *3 1.185,3.881 1.185,3.695 1.185,3.695 1.343,3.695 false 3.594,5.309 3.787,5.461 0.193,0.152 10 *4 1.233,4.128 1.233,4.3 1.233,4.3 1.36,4.3 false 1.36,3.635 1.553,3.788 0.193,0.152 10 *5 6.421,3.595 6.421,3.415 6.421,3.415 6.507,3.415 false 1.393,4.245 1.585,4.397 0.193,0.152 10 *6 6.419,3.906 6.419,4.11 6.419,4.11 6.52,4.11 false 3.98,4.893 3.98,5.365 3.98,5.365 4.059,5.365 false 3.349,4.888 3.349,5.354 3.349,5.354 3.237,5.354 false 6.521,3.36 6.714,3.512 0.193,0.152 10 *7 3.664,4.929 3.664,5.302 false 6.537,4.048 6.730,4.200 0.193,0.152 10 *8

Text in Illustration
*1 Stabilizer Control with Accumulator Housing Bleeder Plug *2 Upper Chamber Stabilizer Control with Accumulator Housing Shutter Valve
*3 Lower Chamber Stabilizer Control with Accumulator Housing Shutter Valve *4 Stabilizer Control Accumulator Housing Inlet Port
*5 Front Stabilizer Control Cylinder Upper Chamber Bleeder Plug *6 Front Stabilizer Control Cylinder Lower Chamber Bleeder Plug
*7 Rear Stabilizer Control Cylinder Upper Chamber Bleeder Plug *8 Rear Stabilizer Control Cylinder Lower Chamber Bleeder Plug


c.

Add new fluid to SST (high pressure oil pump) and bleed air from SST hoses.

SST
09760-60020  

Fluid:

Suspension fluid AHC


NOTICE:

If air is not bled from the hoses, the air will mix into the hydraulic circuit.



d.

Remove the service valve cap. Then put fluid into SST (high pressure oil pump) and connect SST to the suspension fluid inlet port.


e.

Loosen the shutter valves of the stabilizer control with accumulator housing.

C213658E02
5.504,0.391 6.471,0.542 0.967,0.151 10 1 to 2.5 turns 1.471,0.356 1.652,0.521 0.181,0.165 10 *1 2.146,1.25 2.146,0.428 2.146,0.428 1.653,0.428 false 1.903,2.217 1.903,2.639 1.903,2.639 1.692,2.639 false 2.538,2.217 2.538,2.633 2.538,2.633 2.611,2.633 false 2.639,2.555 2.820,2.720 0.181,0.165 10 *2 1.546,2.567 1.727,2.732 0.181,0.165 10 *3 2.143,2.607 2.324,2.772 0.181,0.165 10 *4 2.221,2.255 2.221,2.605 false

Text in Illustration
*1 Stabilizer Control with Accumulator Housing Assembly *2 Upper Chamber Stabilizer Control with Accumulator Housing Shutter Valve
*3 Lower Chamber Stabilizer Control with Accumulator Housing Shutter Valve *4 Stabilizer Control Accumulator Housing Inlet Port

NOTICE:
·

When loosening a shutter valve, loosen it 1 to 2.5 turns, but do not loosen it any more than that.

·

As air may enter the system or fluid may spray out, do not remove the shutter valves.




f.

Using SST (high pressure oil pump), add fluid.

CAUTION:

If a fluid leak is discovered, immediately release the pressure and repair the fluid leak as there is danger involved due to the high pressure.


NOTICE:

Do not allow the pressure to reach 8 MPa (81.6 kgf/cm2, 1160 psi) or higher as the accumulator may be damaged.


i.

Pump SST (high pressure oil pump) to add fluid until the pressure reaches 5 MPa (51.0 kgf/cm2, 725 psi).*1


ii.

Check for fluid leaks from the pipe connections and hydraulic circuit parts.


iii.
C212854

Add fluid to the stabilizer control with accumulator housing.*2

1.

Loosen the bleeder plug of the stabilizer control with accumulator housing.

2.

Pump SST (high pressure oil pump) and maintain a pressure of 5 MPa (51.0 kgf/cm2, 725 psi) until air stops coming out.

3.

Tighten the bleeder plug of the stabilizer control with accumulator housing.


Torque:
8.3 N*m (85 kgf*cm, 73 in.*lbf)


iv.
C216458

Add fluid to the lower chamber of the front stabilizer control cylinder.*3

1.

Pump SST (high pressure oil pump) to add fluid until the pressure reaches 5 MPa (51.0 kgf/cm2, 725 psi).

2.

Loosen the lower chamber bleeder plug of the front stabilizer control cylinder.

3.

Pump SST (high pressure oil pump) and maintain a pressure of 5 MPa (51.0 kgf/cm2, 725 psi) until air stops coming out.

4.

Tighten the lower chamber bleeder plug of the front stabilizer control cylinder.


Torque:
7.9 N*m (81 kgf*cm, 70 in.*lbf)


v.
C214862

Add fluid to the upper chamber of the front stabilizer control cylinder.*4

1.

Pump SST (high pressure oil pump) to add fluid until the pressure reaches 5 MPa (51.0 kgf/cm2, 725 psi).

2.

Loosen the upper chamber bleeder plug of the front stabilizer control cylinder.

3.

Pump SST (high pressure oil pump) and maintain a pressure of 5 MPa (51.0 kgf/cm2, 725 psi) until air stops coming out.

4.

Tighten the upper chamber bleeder plug of the front stabilizer control cylinder.


Torque:
7.9 N*m (81 kgf*cm, 70 in.*lbf)


vi.
C216459

Add fluid to the lower chamber of the rear stabilizer control cylinder.*5

1.

Pump SST (high pressure oil pump) to add fluid until the pressure reaches 5 MPa (51.0 kgf/cm2, 725 psi).

2.

Loosen the lower chamber bleeder plug of the rear stabilizer control cylinder.

3.

Pump SST (high pressure oil pump) and maintain a pressure of 5 MPa (51.0 kgf/cm2, 725 psi) until air stops coming out.

4.

Tighten the lower chamber bleeder plug of the rear stabilizer control cylinder.


Torque:
7.9 N*m (81 kgf*cm, 70 in.*lbf)


vii.
C214863

Add fluid to the upper chamber of the rear stabilizer control cylinder.*6

1.

Pump SST (high pressure oil pump) to add fluid until the pressure reaches 5 MPa (51.0 kgf/cm2, 725 psi).

2.

Loosen the upper chamber bleeder plug of the rear stabilizer control cylinder.

3.

Pump SST (high pressure oil pump) and maintain a pressure of 5 MPa (51.0 kgf/cm2, 725 psi) until air stops coming out.

4.

Tighten the upper chamber bleeder plug of the rear stabilizer control cylinder.


Torque:
7.9 N*m (81 kgf*cm, 70 in.*lbf)


viii.

Repeat procedures *1 to *6 until the air in the fluid is gone.



g.

Using SST (high pressure oil pump), bleed the air.

NOTICE:
·

Be sure to apply 7 MPa (71.4 kgf/cm2, 1015 psi) of pressure to all parts. If the pressure is low, the air may not be released.

·

Do not allow the pressure to reach 8 MPa (81.6 kgf/cm2, 1160 psi) or higher as the accumulator may be damaged.



i.

Bleed air from the stabilizer control with accumulator housing.

1.

Pump SST (high pressure oil pump) to apply 7 MPa (71.4 kgf/cm2, 1015 psi) of pressure.

2.

Loosen the bleeder plug of the stabilizer control with accumulator housing to bleed the air.

3.

Tighten the bleeder plug so pressure can be applied. Repeat these steps until the air in the fluid is gone.

4.

Tighten the bleeder plug of the stabilizer control with accumulator housing.


Torque:
8.3 N*m (85 kgf*cm, 73 in.*lbf)


ii.

Bleed air from the upper chamber of the front stabilizer control cylinder.

1.

Pump SST (high pressure oil pump) to apply 7 MPa (71.4 kgf/cm2, 1015 psi) of pressure.

2.

Loosen the upper chamber bleeder plug of the front stabilizer control cylinder to bleed the air.

3.

Tighten the bleeder plug so pressure can be applied. Repeat these steps until the air in the fluid is gone.

4.

Tighten the upper chamber bleeder plug of the front stabilizer control cylinder.


Torque:
7.9 N*m (81 kgf*cm, 70 in.*lbf)


iii.

Bleed air from the upper chamber of the rear stabilizer control cylinder.

1.

Pump SST (high pressure oil pump) to apply 7 MPa (71.4 kgf/cm2, 1015 psi) of pressure.

2.

Loosen the upper chamber bleeder plug of the rear stabilizer control cylinder to bleed the air.

3.

Tighten the bleeder plug so pressure can be applied. Repeat these steps until the air in the fluid is gone.

4.

Tighten the upper chamber bleeder plug of the rear stabilizer control cylinder.


Torque:
7.9 N*m (81 kgf*cm, 70 in.*lbf)



h.
C214858E01
0.75,1.031 2.042,1.25 1.292,0.219 10 411.5 to 417.5 mm

Disconnect the front stabilizer control arm and front stabilizer link, and set the front stabilizer control cylinder to the maximum length.

Maximum length:

411.5 to 417.5 mm (16.2 to 16.4 in.)


NOTICE:

Set the front stabilizer control cylinder to the maximum length to completely bleed the air.


HINT:

Refer to the following procedures to disconnect the front stabilizer control arm and front stabilizer link (See page Suspension>FRONT SUSPENSION>FRONT STABILIZER BAR (w/ KDSS)>REMOVAL).



i.
C214859E01
0.698,1.042 1.979,1.24 1.281,0.198 10 386.5 to 392.5 mm

Disconnect the rear stabilizer bar and rear stabilizer link, and set the rear stabilizer control cylinder to the maximum length.

Maximum length:

386.5 to 392.5 (15.2 to 15.4 in.)


NOTICE:

Set the rear stabilizer control cylinder to the maximum length to completely bleed the air.


HINT:

Refer to the following procedures to disconnect the rear stabilizer bar and rear stabilizer link (See page Suspension>REAR SUSPENSION>REAR STABILIZER BAR (w/ KDSS)>REMOVAL).



j.

Bleed air from the lower chamber of the front stabilizer control cylinder.

i.

Pump SST (high pressure oil pump) to apply 7 MPa (71.4 kgf/cm2, 1015 psi) of pressure.


ii.

Loosen the lower chamber bleeder plug of the front stabilizer control cylinder to bleed the air.


iii.

Tighten the bleeder plug so pressure can be applied. Repeat these steps until the air in the fluid is gone.


iv.

Tighten the lower chamber bleeder plug of the front stabilizer control cylinder.

Torque:
7.9 N*m (81 kgf*cm, 70 in.*lbf)



k.

Bleed air from the lower chamber of the rear stabilizer control cylinder.

i.

Pump SST (high pressure oil pump) to apply 7 MPa (71.4 kgf/cm2, 1015 psi) of pressure.


ii.

Loosen the lower chamber bleeder plug of the rear stabilizer control cylinder to bleed the air.


iii.

Tighten the bleeder plug so pressure can be applied. Repeat these steps until the air in the fluid is gone.


iv.

Tighten the lower chamber bleeder plug of the rear stabilizer control cylinder.

Torque:
7.9 N*m (81 kgf*cm, 70 in.*lbf)



l.

Connect the front stabilizer control arm to the front stabilizer link and the rear stabilizer bar to the rear stabilizer link.

HINT:
·

For the front side, refer to the following procedures (See page Suspension>FRONT SUSPENSION>FRONT STABILIZER BAR (w/ KDSS)>INSTALLATION).

·

For the rear side, refer to the following procedures (See page Suspension>REAR SUSPENSION>REAR STABILIZER BAR (w/ KDSS)>INSTALLATION).




m.

With all wheels on the ground, apply the specified amount of pressure using SST. Maintain this pressure for 2 to 3 minutes to stabilize the pressure.

NOTICE:
·

Refer to the Temperature Management Chart when Filling Fluid as the specified pressure changes according to the fluid temperature.

·

Perform the inspection with the vehicle load completely on the suspension.



HINT:
·

Perform this step with the fuel tank full.

·

If there are any parts installed to the vehicle which place any unbalanced load on the left or right side of the vehicle, remove them.



Standard Fluid Pressure:
Condition Specified Condition
Fluid temperature is 20°C (68°F) 2.6 to 3 MPa (26.6 to 30.5 kgf/cm2, 377 to 435 psi)




o.

Tighten the shutter valves of the stabilizer control with accumulator housing.

Torque:
9.0 N*m (92 kgf*cm, 80 in.*lbf)


p.

Remove SST (high pressure oil pump) from the suspension fluid inlet port.

NOTICE:

Make sure that no pressure is applied to SST (high pressure oil pump).



q.

Install the service valve caps to the suspension fluid inlet port.

Torque:
0.6 N*m (6.0 kgf*cm, 5.0 in.*lbf)



s.

Install the stabilizer control valve protector (See page Suspension>SUSPENSION CONTROL>STABILIZER CONTROL TUBE (w/ KDSS)>INSTALLATION).


Hide 2. TEMPERATURE MANAGEMENT CHART WHEN FILLING FLUID

C213650E01
2.714,0.067 5.582,0.309 2.868,0.242 10 Upper Side: Charged Pressure Upper Limit 2.719,0.46 5.576,0.694 2.858,0.235 10 Lower Side: Charged Pressure Lower Limit 0.169,4.195 1.105,4.377 0.936,0.183 10 2.2 (22.4, 319) 0.17,3.702 1.100,3.885 0.930,0.183 10 2.4 (24.5, 348) 0.168,3.229 1.106,3.412 0.939,0.183 10 2.6 (26.5, 377) 0.174,2.762 1.106,2.944 0.933,0.183 10 2.8 (28.6, 406) 0.168,2.269 1.101,2.452 0.933,0.183 10 3.0 (30.6, 435) 0.172,1.799 1.104,1.971 0.932,0.172 10 3.2 (32.6, 464) 0.165,1.308 1.102,1.490 0.937,0.183 10 3.4 (34.7, 493) 0.163,0.843 1.098,1.026 0.935,0.183 10 3.6 (36.7, 522) 0.343,0.111 0.985,0.305 0.642,0.194 10 Pressure 0.049,0.441 1.232,0.625 1.184,0.184 10 MPa (kgf/cm2, psi) 2.119,4.826 2.266,4.987 0.147,0.161 10 0 2.591,4.823 2.737,4.993 0.146,0.170 10 5 3.028,4.824 3.288,4.989 0.260,0.165 10 10 3.507,4.825 3.755,4.995 0.248,0.170 10 15 3.98,4.825 4.200,4.994 0.221,0.169 10 20 4.455,4.827 4.664,5.013 0.209,0.186 10 25 4.932,4.829 5.142,4.994 0.209,0.165 10 30 5.411,4.827 5.604,4.983 0.193,0.156 10 35 5.889,4.826 6.102,4.991 0.213,0.165 10 40 6.361,4.824 6.545,4.969 0.184,0.145 10 45 2.045,5.083 2.320,5.257 0.275,0.174 10 (32) 2.498,5.089 2.774,5.250 0.276,0.161 10 (41) 2.989,5.104 3.256,5.278 0.267,0.174 10 (50) 3.459,5.105 3.777,5.252 0.318,0.147 10 (59) 3.933,5.105 4.225,5.277 0.292,0.172 10 (68) 4.407,5.107 4.690,5.272 0.283,0.165 10 (77) 4.894,5.108 5.195,5.279 0.301,0.171 10 (86) 5.376,5.107 5.662,5.274 0.286,0.167 10 (95) 5.805,5.106 6.155,5.276 0.350,0.170 10 (104) 6.305,5.104 6.674,5.260 0.369,0.156 10 (113) 3.69,5.422 5.351,5.626 1.662,0.205 10 Fluid Temperature °C (°F) 0.17,4.646 1.105,4.829 0.935,0.183 10 2.0 (20.4, 290) 6.837,4.825 7.020,4.971 0.184,0.145 10 50 6.781,5.105 7.149,5.261 0.369,0.156 10 (122) 1.587,4.826 1.800,4.995 0.213,0.170 10 -5 1.545,5.087 1.821,5.247 0.276,0.161 10 (23) 1.101,4.817 1.361,4.982 0.260,0.165 10 -10 1.1,5.088 1.367,5.261 0.267,0.174 10 (14) 1.594,3.527 1.770,3.697 0.177,0.170 10 *1 2.165,3.362 2.341,3.532 0.177,0.170 10 *2 2.56,3.156 2.737,3.325 0.177,0.170 10 *3 3.009,2.954 3.186,3.123 0.177,0.170 10 *4 3.507,2.69 3.684,2.859 0.177,0.170 10 *5 3.981,2.448 4.158,2.618 0.177,0.170 10 *6 4.446,2.217 4.623,2.387 0.177,0.170 10 *7 4.927,2.034 5.104,2.203 0.177,0.170 10 *8 5.31,1.882 5.487,2.052 0.177,0.170 10 *9 5.828,1.592 6.064,1.762 0.236,0.170 10 *10 6.208,1.405 6.440,1.575 0.232,0.170 10 *11 1.577,3.927 1.810,4.097 0.232,0.170 10 *12 2.21,3.642 2.442,3.812 0.232,0.170 10 *13 2.668,3.467 2.900,3.637 0.232,0.170 10 *14 3.136,3.353 3.368,3.523 0.232,0.170 10 *15 3.616,3.122 3.848,3.291 0.232,0.170 10 *16 4.092,2.912 4.325,3.081 0.232,0.170 10 *17 4.576,2.691 4.808,2.861 0.232,0.170 10 *18 5.038,2.586 5.270,2.756 0.232,0.170 10 *19 5.518,2.46 5.750,2.629 0.232,0.170 10 *20 6.008,2.202 6.240,2.372 0.232,0.170 10 *21 6.474,1.987 6.706,2.157 0.232,0.170 10 *22

Text in Illustration
*1 2.42 MPa (24.7 kgf/cm2, 351 psi) *2 2.50 MPa (25.5 kgf/cm2, 363 psi)
*3 2.59 MPa (26.4 kgf/cm2, 376 psi) *4 2.67 MPa (27.2 kgf/cm2, 387 psi)
*5 2.76 MPa (28.1 kgf/cm2, 400 psi) *6 2.85 MPa (29.1 kgf/cm2, 413 psi)
*7 2.95 MPa (30.1 kgf/cm2, 428 psi) *8 3.05 MPa (31.1 kgf/cm2, 442 psi)
*9 3.27 MPa (33.3 kgf/cm2, 474 psi) *10 3.27 MPa (33.3 kgf/cm2, 474 psi)
*11 3.38 MPa (34.5 kgf/cm2, 490 psi) *12 2.39 MPa (24.4 kgf/cm2, 347 psi)
*13 2.46 MPa (25.1 kgf/cm2, 357 psi) *14 2.53 MPa (25.8 kgf/cm2, 367 psi)
*15 2.60 MPa (26.5 kgf/cm2, 377 psi) *16 2.67 MPa (27.2 kgf/cm2, 387 psi)
*17 2.75 MPa (28.0 kgf/cm2, 399 psi) *18 2.82 MPa (28.8 kgf/cm2, 409 psi)
*19 2.90 MPa (29.6 kgf/cm2, 421 psi) *20 2.98 MPa (30.4 kgf/cm2, 432 psi)
*21 3.06 MPa (31.2 kgf/cm2, 444 psi) *22 3.14 MPa (32.0 kgf/cm2, 455 psi)