HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  Weak Blower Output  


DESCRIPTION

If the airflow from the registers is weak regardless of the blower speed setting displayed on the air conditioning control assembly, the following factors may be the cause.

Symptom Factor
·

Blower airflow volume is continuously weak.

·

Blower airflow volume is sometimes weak.


·

Customize setting

·

Control signal malfunction between air conditioning assembly and blower with fan motor sub-assembly

·

Control signal malfunction between air conditioning assembly and rear blower with fan motor sub-assembly (w/ Rear Cooler, w/ Rear Air Conditioning System)

·

Blower motor with fan sub-assembly malfunction

·

Rear blower motor with fan sub-assembly malfunction (w/ Rear Cooler, w/ Rear Air Conditioning System)

·

Air conditioning amplifier assembly malfunction

·

Evaporator or heater core fin clogging

·

Clean air filter clogging

·

No. 1 cooler thermistor malfunction

·

No. 2 cooler thermistor malfunction (w/ Rear Cooler, w/ Rear Air Conditioning System)

·

Aspirator loser malfunction



PROCEDURE

1.CHECK MALFUNCTION STATUS
Result:
Result Proceed to
Malfunction occurs front side A
Malfunction occurs rear side (w/ Rear Cooler, w/ Rear Air Conditioning System) B



A

2.CHECK AIR CONDITIONING SYSTEM

B

7.CHECK AIR CONDITIONING SYSTEM
2.CHECK AIR CONDITIONING SYSTEM
a.

Operate the blower switch with the following conditions met and check that the airflow volume changes.

Blower Speed Condition
LO → HI
·

Temperature setting: MAX COLD

·

Air outlet mode: FACE

·

A/C switch: Off



OK:

Airflow volume increases.



Result:
Proceed to
OK
NG



OK

3.CHECK ECO MODE SETTING

NG

GO TO OTHER DIAGNOSIS PROCEDURE (Blower Motor Circuit)

3.CHECK ECO MODE SETTING
a.

Confirm that ECO HEAT/COOL switch is set to off.


b.

Confirm that ECO drive mode is set to off.

HINT:

When the ECO drive mode is set to ON, the air conditioning amplifier assembly performs minimal air conditioning control in order to promote the improvement of fuel economy. Ensure that the customer understands that the airflow volume will be decreased compared to normal operation.

Control Control Summary
Air Volume Control Sets the blower level to less.



Result:
Proceed to
NEXT



NEXT

4.CHECK CLEAN AIR FILTER
4.CHECK CLEAN AIR FILTER
a.

Visually check the clean air filter.

OK:

The clean air filter is not dirty or clogging.



Result:
Proceed to
OK
NG



OK

5.CHECK NO. 1 COOLER THERMISTOR

NG

5.CHECK NO. 1 COOLER THERMISTOR
a.

Check the installation condition of the No. 1 cooler thermistor.

OK:

The No. 1 cooler thermistor is installed correctly.



Result:
Proceed to
OK
NG



OK

6.CHECK ASPIRATOR

NG

6.CHECK ASPIRATOR
a.

Check the installation condition of the aspirator.

OK:

The aspirator is installed correctly.



Result:
Proceed to
OK
NG



OK

NG

7.CHECK AIR CONDITIONING SYSTEM
a.

Operate the blower switch with the following conditions met and check that the airflow volume changes.

Blower Speed Condition
LO → HI
·

Temperature setting: MAX COLD

·

Air outlet mode: FACE

·

A/C switch: Off



OK:

Airflow volume increases.



Result:
Proceed to
OK
NG



OK

8.CHECK ECO MODE SETTING

NG

GO TO OTHER DIAGNOSIS PROCEDURE (Rear Blower Motor Circuit)

8.CHECK ECO MODE SETTING
a.

Confirm that ECO HEAT/COOL switch is set to off.


b.

Confirm that ECO drive mode is set to off.

HINT:

When the ECO drive mode is set to ON, the air conditioning amplifier assembly performs minimal air conditioning control in order to promote the improvement of fuel economy. Ensure that the customer understands that the airflow volume will be decreased compared to normal operation.

Control Control Summary
Air Volume Control Sets the blower level to less.



Result:
Proceed to
NEXT



NEXT

9.CHECK CLEAN AIR FILTER
9.CHECK CLEAN AIR FILTER
a.

Visually check the clean air filter.

OK:

The clean air filter is not dirty or clogging.



Result:
Proceed to
OK
NG



OK

10.CHECK NO. 2 COOLER THERMISTOR

NG

10.CHECK NO. 2 COOLER THERMISTOR
a.

Check the installation condition of the No. 2 cooler thermistor.

OK:

The No. 2 cooler thermistor is installed correctly.



Result:
Proceed to
OK
NG



OK

REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR REAR COOLER EVAPORATOR SUB-ASSEMBLY

NG

REINSTALL NO. 1 COOLER WIRING HARNESS SUB-ASSEMBLY