Refer to high voltage system diagram for the System Description.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>SYSTEM DESCRIPTION
If an overcurrent occurs in the FC converter assembly, the FC boost control ECU detects a malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1D0619 | FC Converter Phase U Current Circuit Current Above Threshold | Phase U fail signal is detected. (Overcurrent)
(1 trip detection logic) |
·
FC converter assembly ·
Inverter with converter assembly ·
FC air compressor with motor assembly ·
FCV transaxle with motor assembly ·
Inverter cooling system ·
Cooling fan system ·
Wire harness or connector |
Master Warning: Comes on | FCDC | B |
| P1D0719 | FC Converter Phase V Current Circuit Current Above Threshold | Phase V fail signal is detected. (Overcurrent)
(1 trip detection logic) |
·
FC converter assembly ·
Inverter with converter assembly ·
FC air compressor with motor assembly ·
FCV transaxle with motor assembly ·
Inverter cooling system ·
Cooling fan system ·
Wire harness or connector |
Master Warning: Comes on | FCDC | B |
| P1D0819 | FC Converter Phase W Current Circuit Current Above Threshold | Phase W fail signal is detected. (Overcurrent)
(1 trip detection logic) |
·
FC converter assembly ·
Inverter with converter assembly ·
FC air compressor with motor assembly ·
FCV transaxle with motor assembly ·
Inverter cooling system ·
Cooling fan system ·
Wire harness or connector |
Master Warning: Comes on | FCDC | B |
| P1D0919 | FC Converter Phase X Current Circuit Current Above Threshold | Phase X fail signal is detected. (Overcurrent)
(1 trip detection logic) |
·
FC converter assembly ·
Inverter with converter assembly ·
FC air compressor with motor assembly ·
FCV transaxle with motor assembly ·
Inverter cooling system ·
Cooling fan system ·
Wire harness or connector |
Master Warning: Comes on | FCDC | B |
If the inverter is malfunctioning, DTCs related to the inverter are also output to the EV control ECU.
| DTC No. | Data List |
|---|---|
| P1D0619 | Phase U Current |
| P1D0719 | Phase V Current |
| P1D0819 | Phase W Current |
| P1D0919 | Phase X Current |
Refer to the wiring diagram for the motor resolver circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor Resolver Circuit
Refer to the wiring diagram for the FC air compressor resolver circuit.
Refer to the wiring diagram for the high-voltage circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA649
Refer to the wiring diagram for the inverter low-voltage circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Inverter Low-voltage Circuit
Refer to the wiring diagram for the FC boost converter low-voltage circuit.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>ECU Power Source Circuit
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side.
Make sure to remove the EV supply battery assembly service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (w/ 1500W Type Voltage Inverter)
After removing the service plug grip from the EV supply battery assembly, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system. After removing the FC converter power outlet cable (inverter with converter assembly) on FC converter side and use the "HIGH-VOLTAGE, DO NOT TOUCH" sign to notify other technicians that you are working on the high-voltage system.
After removal of the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, wait for at least 10 minutes before touching the high-voltage connectors and terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
At least 10 minutes are necessary to discharge the high-voltage capacitors inside the inverter with converter assembly and FC stack assembly.
Since high voltage accumulates within the FC stack assembly with FC converter, never perform the work of separating the FC stack assembly with FC converter into the FC converter assembly and FC stack assembly without first performing electrical charge discharge (forced electrical charge discharge or electrical charge self-discharge), because doing so is dangerous.
Click hereEngine / Hybrid System>FC CONTROL>FC STACK>REMOVAL
Removing and installing the FC stack assembly without first discharging the electrical charge may result in an electric shock due to the high voltage circuit.
When reinstalling the service plug grip to the EV supply battery assembly, after lowering the EV supply battery assembly service plug grip 90°, securely slide it until a "click" sound is heard.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>PRECAUTION
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON.
Enter the following menus: Powertrain / EV / Data List / FC Work Mode, FC Intermittent Operation.
Put the state in park (P), turn the ignition switch to ON (READY) and wait until the FC system is activated (Waiting for at least 2 minutes is required after turning the ignition switch to ON (READY)).
FC system is activated: Data List shows that "FC Work Mode" is "Working" and "FC Intermittent Operation" is "OFF".
Wait at least 15 seconds with the FC system activated.
Drive the vehicle forward with the shift state in drive (D) for 5 m (16 ft.) or more.
Drive the vehicle backward with the shift state in reverse (R) for 5 m (16 ft.) or more.
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P1D0619, P1D0719, P1D0819 or P1D0919 is output | A |
| P1D0619, P1D0719, P1D0819 or P1D0919 is output and DTCs other than the DTCs in the table below are output | B |
| P1D0619, P1D0719, P1D0819 or P1D0919 is output and any DTCs in the table below are output | C |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Microcomputer malfunction | P060B16 | Internal Control Module A/D Processing Performance Circuit Voltage Below Threshold |
| P060B1C | Internal Control Module A/D Processing Performance Circuit Voltage Out of Range | |
| P060B49 | Internal Control Module A/D Processing Performance Internal Electronic Failure | |
| P060B71 | Internal Control Module A/D Processing Performance Actuator Stuck | |
| P1F451F | FC Converter Control Module Power Relay Sense Circuit Intermittent | |
| Sensor and actuator circuit malfunction | P1D1C16 | FC Converter Output Voltage Sensor Circuit Voltage Below Threshold |
| P1D1C17 | FC Converter Output Voltage Sensor Circuit Voltage Above Threshold | |
| P1D2017 | FC Converter Input Voltage Sensor Circuit Voltage Above Threshold | |
| System malfunction | P1D0E62 | Inverter Output Voltage/FC Converter Output Voltage Signal Compare Failure |
| P1D0F62 | Cell Monitor Voltage/FC Converter Input Voltage Signal Compare Failure | |
DTC P1D0619, P1D0719, P1D0819 or P1D0919 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| No DTCs in the table below are output | A |
| Any of the DTCs in the table below are output | B |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| System malfunction | P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | |
DTC P1D0619, P1D0719, P1D0819 or P1D0919 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed to EV supply battery assembly and the FC converter power outlet cable (inverter with converter assembly) is not connected to the FC converter assembly.
After removing the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the electric heater sub-assembly.
Procedure1
Check the connection condition of the FC converter assembly connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
When connecting the connector, connect it with the lock levers raised. Rotate each lock lever downward and make sure that the connector is securely connected. When a lock lever is fully lowered, a click will be heard as its claw engages. After the click is heard, pull up on the connector to confirm that it is securely connected.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
Post-procedure1
Replace the electric heater sub-assembly.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed to EV supply battery assembly and the FC converter power outlet cable (inverter with converter assembly) is not connected to the FC converter assembly.
After removing the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Procedure1
Check the connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| *A | for LHD | *B | for RHD |
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
When connecting the connector, connect it with the lock levers raised. Rotate each lock lever downward and make sure that the connector is securely connected. When a lock lever is fully lowered, a click will be heard as its claw engages. After the click is heard, pull up on the connector to confirm that it is securely connected.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
Post-procedure1
None
A
B
C
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>Cooling System
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor Resolver Circuit
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor High-voltage Circuit
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Put the state in park (P), turn the ignition switch to ON (READY) and wait until the FC system is activated. (Waiting for at least 2 minutes is required after turning the ignition switch to ON (READY))
| Tester Display |
|---|
| FC Work Mode |
| FC Intermittent Operation |
FC system is activated: Data List shows that "FC Work Mode" is "Working" and "FC Intermittent Operation" is "OFF".
Wait at least 15 seconds with the FC system activated.
Drive the vehicle forward with the shift state in drive (D) for 5 m (16 ft.) or more.
Drive the vehicle backward with the shift state in reverse (R) for 5 m (16 ft.) or more.
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTCs are output | B |
Post-procedure1
Turn the ignition switch off.
A