MALFUNCTION DESCRIPTION
When the ignition switch is turned from ON (READY) to off, the EV control ECU detect that the high-voltage capacitor inside the inverter with converter assembly is not discharged.
The cause of this malfunction may be one of the following:
Voltage sensor (VH) malfunction
Motor generator control ECU (MG ECU) malfunction
Communication (wire harness) malfunction
Inverter with converter assembly malfunction
EV control ECU malfunction
Wire harness malfunction
Inverter with converter assembly malfunction
FCDC converter control ECU malfunction
Refer to the description for DTC P0D2D16.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0D2D16
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | The inverter voltage (VH) does not drop during discharge.
(Discharge: Offsetting of the residual pressure in the high-voltage side after ignition switch is turned off) (1 trip detection logic) |
·
Inverter with converter assembly ·
Wire harness or connector ·
EV control ECU |
Master Warning:
Comes on |
EV | A |
When theignition switch is turned from ON (READY) to off, the MG ECU discharges voltage stored in the inverter by allowing current to flow to motor (MG2) without generating torque. When the vehicle is normal, VH voltage becomes approximately 0 V after discharging. If VH voltage exceeds a specified value, this DTC is stored.
| DTC No. | Data List |
|---|---|
| P0C7600 | VH-Voltage after Boosting
FC Converter Shutdown Status |
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 10 minutes or more.
Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
Turn the ignition switch off and wait for 10 minutes or more.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for the shut down signal circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Shut Down Signal Circuit
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0C7600 only is output, or DTCs except the ones in the table below are also output. | A |
| Any hybrid control system DTCs in the table below are output | B |
| Any FC control system DTCs in the table below are output | C |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Hybrid control system | P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ||
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | ||
| P1C9E9F | Hybrid/EV System Reset Stuck Off | ||
| P0A1B1F | Drive Motor "A" Control Module Circuit Intermittent | ||
| P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
| P1C2B00 | Drive Motor "A" Control Module A/D Processing Performance | ||
| P0A1B04 | Drive Motor "A" Control Module System Internal Failure | ||
| P1CA700 | Drive Motor "A" Control Module RAM/ROM Error | ||
| P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | ||
| P1D0400 | FC Air Compressor Motor Control Module A/D Processing Performance | ||
| P1D0500 | FC Air Compressor Motor Control Module RAM/ROM Error | ||
| P1D8F04 | FC Air Compressor Motor Control Module System Internal Failure | ||
| P1D8F47 | FC Air Compressor Motor Control Module Watchdog/Safety MCU Failure | ||
| P1D8F49 | FC Air Compressor Motor Control Module Internal Electronic Failure | ||
| P1E8649 | FC Air Compressor Motor Position Sensor Internal Electronic Failure | ||
| P1C731C | Sensor Reference Voltage "H" Circuit/Open Circuit Voltage Out of Range | ||
| P1E3B87 | Communication Error from FC Air Compressor Motor to Drive Motor "A" Missing Message | ||
| Power source circuit malfunction | Hybrid control system | P06D61C | Sensor Reference Voltage "F" Circuit/Open Circuit Voltage Out of Range |
| P06B01C | Sensor Power Supply "A" Circuit/Open Circuit Voltage Out of Range | ||
| P06E61C | Sensor Power Supply "C" Circuit/Open Circuit Voltage Out of Range | ||
| Communication system malfunction | Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| Sensor and actuator circuit malfunction | Hybrid control system | P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground | ||
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold | ||
| P0A1B00 | Drive Motor "A" Control Module Performance | ||
| P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
| P1CB300 | Drive Motor "A" Position Sensor REF Signal Oscillation Stop | ||
| P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold | ||
| P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum | ||
| P0A3F1C | Drive Motor "A" Position Sensor Circuit Voltage Out of Range | ||
| P1D8F00 | FC Air Compressor Motor Control Module Performance | ||
| P1E8738 | FC Air Compressor Motor Position Sensor REF Signal Frequency Incorrect | ||
| P1E8800 | FC Air Compressor Motor Position Sensor REF Signal Oscillation Stop | ||
| P1D7516 | FC Air Compressor Motor Position Sensor Circuit Voltage Below Threshold | ||
| P1D7522 | FC Air Compressor Motor Position Sensor Signal Amplitude > Maximum | ||
| P1D751C | FC Air Compressor Motor Position Sensor Circuit Voltage Out of Range | ||
| FC control system | P1E9011 | FC Positive Contactor Control Circuit Short to Ground | |
| P1E9015 | FC Positive Contactor Control Circuit Short to Battery or Open | ||
| P1E9211 | FC Precharge Contactor Control Circuit Short to Ground | ||
| P1E9215 | FC Precharge Contactor Control Circuit Short to Battery or Open | ||
| P1E9111 | FC Negative Contactor Control Circuit Short to Ground | ||
| P1E9115 | FC Negative Contactor Control Circuit Short to Battery or Open | ||
| System malfunction | Hybrid control system | P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range |
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction | ||
| P1E1500 | FC Positive Contactor Actuator Stuck Closed | ||
| P1E1773 | FC Negative Contactor Control Actuator Stuck Closed | ||
| P1E1573 | FC Positive and Negative Contactor Actuator Stuck Closed | ||
| P0D2D16 | Drive Motor "A" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold | ||
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold | ||
| P1CB69E | Drive Motor "A" Inverter Overvoltage Signal Stuck On | ||
| P1D9514 | FC Converter Shutdown Signal Circuit Short to Ground or Open | ||
| P1D9512 | FC Converter Shutdown Signal Circuit Short to Battery | ||
| P1E0A14 | FC Converter Fail Signal Circuit Short to Ground or Open | ||
| P1E0A12 | FC Converter Fail Signal Circuit Short to Battery | ||
| FC control system | P1D0619 | FC Converter Phase U Current Circuit Current Above Threshold | |
| P1DDA4B | FC Converter Phase U Over Temperature | ||
| P1DDA9E | FC Converter Phase U Fail Signal Stuck On | ||
| P1D0719 | FC Converter Phase V Current Circuit Current Above Threshold | ||
| P1DDB4B | FC Converter Phase V Over Temperature | ||
| P1DDB9E | FC Converter Phase V Fail Signal Stuck On | ||
| P1D0819 | FC Converter Phase W Current Circuit Current Above Threshold | ||
| P1DDC4B | FC Converter Phase W Over Temperature | ||
| P1DDC9E | FC Converter Phase W Fail Signal Stuck On | ||
| P1D0919 | FC Converter Phase X Current Circuit Current Above Threshold | ||
| P1DDD4B | FC Converter Phase X Over Temperature | ||
| P1DDD9E | FC Converter Phase X Fail Signal Stuck On | ||
| P1F0117 | FC Converter Output Voltage Circuit Voltage Above Threshold | ||
| P1F009E | FC Converter Overvoltage Signal Stuck On | ||
P0C7600 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Pre-procedure1
None.
Procedure1
Read the freeze frame data of DTC P0C7600.
| Tester Display | Measurement Item | Range |
|---|---|---|
| FC Converter Shutdown Status | FC boost converter shutdown status | ON/OFF |
| Tester Display |
|---|
| FC Converter Shutdown Status |
As freeze frame data is stored immediately before and after a DTC is stored, make sure to only read the values for the moment the DTC was stored ("0(s)").
| Result | Proceed to |
|---|---|
| FC Converter Shutdown Status is OFF | A |
| FC Converter Shutdown Status is ON | B |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Shut Down Signal Circuit
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Shut Down Signal Circuit
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Shut Down Signal Circuit
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
Procedure1
Read the value of "VH-Voltage after Boosting" displayed on the GTS.
| Tester Display | Measurement Item | Range |
|---|---|---|
| VH-Voltage after Boosting | High voltage after it is boosted | - |
| Tester Display |
|---|
| VH-Voltage after Boosting |
| Result | Proceed to |
|---|---|
| The value of VH-Voltage after Boosting is less than 50 V. | A |
| None of the above conditions are met | B |
Post-procedure1
None.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P06881F
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1D9512 or P1E0A12 is output | A |
| None of the above conditions are met | B |
Post-procedure1
Turn the ignition switch off.
A
B