MALFUNCTION DESCRIPTION
The hybrid vehicle control ECU monitors the high-voltage wiring between the HV battery and hybrid motor control inverter assembly and detects a power supply malfunction.
The cause of this malfunction may be one of the following:
Voltage sensor (VH) malfunction
Motor generator control ECU (MG ECU) malfunction
Communication (wire harness) malfunction
HV battery malfunction
No. 1 traction battery device box assembly malfunction
Hybrid motor control inverter assembly malfunction
Rear hybrid motor control inverter assembly (for AWD)
High-voltage wire harness malfunction
High-voltage connector or connection malfunction
Hybrid vehicle control ECU malfunction
No. 1 traction battery device box assembly malfunction
Low voltage wire harness malfunction
Low voltage connector malfunction
INSPECTION DESCRIPTION
| System Diagram Range | Inspection Content | Reason |
|---|---|---|
| *a | Check connection condition and wire harness continuity between hybrid vehicle control ECU and No. 1 traction battery device box assembly | In order to check whether connectors are connected properly and to check for an open circuit in the SMRP and SMRB primary lines |
| *b | Check system main relay | Check whether SMRB and SMRP stuck OFF |
| *c | Check connection condition and high-voltage cable continuity between No. 1 traction battery device box assembly and hybrid motor control inverter assembly or rear hybrid motor control inverter assembly | Check for open circuit and defective connection (arc marks) due to looseness |
| *d | Check high-voltage cable and connection condition between HV battery and No. 1 traction battery device box assembly | Check for open circuit and defective connection (arc marks) due to looseness |
| *e | Check HV battery | Check whether HV battery voltage has drastically dropped below normal range |
Refer to the description for DTC P0AE411.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE411
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction | Although an SMR on request was sent when the ignition switch is operated, the voltage did not increase after boosting.
High-voltage circuit malfunctions between the HV battery and hybrid motor control inverter assembly. The EV electric battery fuse is blown, the service plug grip is removed, the system main resistor is blown, SMRP or SMRB remains open, or the high-voltage cable has an open circuit. (1 trip detection logic) |
·
No. 1 Traction Battery Device Box Assembly ·
HV floor under wire ·
Hybrid motor control inverter assembly ·
No. 1 HV supply stack sub-assembly ·
No. 2 HV supply stack sub-assembly ·
Hybrid battery terminal block ·
Electric vehicle battery plug assembly ·
Rear hybrid motor control inverter assembly* ·
HV battery pack wire* ·
Wire harness or connector |
Does not come on | Master Warning: Comes on | Hybrid Control | A |
*: for AWD
| DTC No. | Data List |
|---|---|
| P1C8349 | ·
Hybrid/EV Battery Voltage ·
Hybrid/EV Battery Current ·
VL-Voltage before Boosting ·
VH-Voltage after Boosting |
The following items can be helpful when performing repairs:
Ready Signal
Inter Lock Switch
SMRP Status
SMRB Status
SMRG Status
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
Turn the ignition switch off and wait for 2 minutes or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for DTC P0AA649.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA649
Refer to the wiring diagram for the HV Battery High-voltage Line Circuit.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
*: for AWD
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
| *a | Dealer |
| *b | Battery Collection Agent |
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Before returning the HV battery, make sure to perform a recovery inspection.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION
Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.
After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1C8349 and Microcomputer malfunction of Hybrid control system DTCs in the table below are output | A |
| P1C8349 and Microcomputer malfunction of Motor generator control system DTCs in the table below are output | B |
| P1C8349 and Microcomputer malfunction of Hybrid battery system DTCs in the table below are output | C |
| P1C8349 and Power source circuit malfunction of Motor generator control system DTCs in the table below are output | D |
| P1C8349 and Communication system malfunction of Hybrid control system DTCs in the table below are output | E |
| P1C8349 and Sensor and actuator circuit malfunction of Hybrid control system DTCs in the table below are output | F |
| P1C8349 and Sensor and actuator circuit malfunction of Hybrid battery system DTCs in the table below are output | G |
| P1C8349 and System malfunction of Hybrid control system DTCs in the table below are output | H |
| P1C8349 and System malfunction of Motor generator control system DTCs in the table below are output | I |
| P1C8349 and DTCs other than the DTCs in the table below are output | J |
| Only P1C8349 is output | K |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure | ||
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ||
| P1C9E9F | Hybrid/EV System Reset Stuck Off | ||
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure | ||
| Motor generator control system | P0A1B1F | Generator Control Module Circuit Intermittent | |
| P0A1A47 | Generator Control Module Watchdog / Safety MC Failure | ||
| P0A1A49 | Generator Control Module Internal Electronic Failure | ||
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
| P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
| P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | ||
| Hybrid battery system | P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message | ||
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance | ||
| Power source circuit malfunction | Motor generator control system | P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| Communication system malfunction | Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message | ||
| Sensor and actuator circuit malfunction | Hybrid control system | P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground | ||
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range | ||
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance | ||
| Hybrid battery system | P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground | |
| P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground | ||
| P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open | ||
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open | ||
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range | ||
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range | ||
| P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range | ||
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range | ||
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery | ||
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open | ||
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure | ||
| System malfunction | Hybrid control system | P0C7600 | Hybrid/EV Battery System Discharge Time Too Long |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | ||
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short | ||
| P1C8249 | High Voltage Power Resource Circuit Over Loading | ||
| P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation | ||
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge | ||
| Motor generator control system | P0D2D16 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold | |
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold | ||
| P1CB69E | Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On | ||
| P0CA300 | DC/DC Converter Step Up Voltage Performance | ||
P1C8349 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
D
E
F
G
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
H
I
J
K
Pre-procedure1
None.
Procedure1
Read the freeze frame data of DTC P1C8349.
| Tester Display |
|---|
| VL-Voltage before Boosting |
| VH-Voltage after Boosting |
| Hybrid/EV Battery Voltage |
| Hybrid/EV Battery Current |
| Result | Proceed to |
|---|---|
| All of the following conditions are met:
·
Difference between "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" is 32 V or less. ·
Difference between "Hybrid/EV Battery Voltage" and "VH-Voltage after Boosting" is more than 33 V. ·
Difference between "VL-Voltage before Boosting" and "VH-Voltage after Boosting" is more than 56 V. |
A |
| In addition to the above conditions, "Hybrid/EV Battery Current" is 3 A or more. | B |
| Except above | C |
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA000
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA000
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for 2WD | A |
| for AWD | B |
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P06881F
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None.
Procedure1
Check if DTCs are output (including pending DTCs).
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| P300449 is output | B |
| P1C8349 is output | C |
| None of the above conditions are met | D |
Because P300449 uses 2-trip detection logic, the DTC detection conditions need to be met 2 times.
Post-procedure1
Turn the ignition switch off.
A
B
C
D
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG