MALFUNCTION DESCRIPTION
The hybrid vehicle control ECU monitors the high-voltage wiring between the HV battery and hybrid motor control inverter assembly and detects an open circuit malfunction.
The cause of this malfunction may be one of the following:
Voltage sensor (VH) malfunction
Motor generator control ECU (MG ECU) malfunction
Communication (wire harness) malfunction
HV battery malfunction
No. 1 traction battery device box assembly malfunction
Hybrid motor control inverter assembly malfunction
Rear hybrid motor control inverter assembly (for AWD)
High-voltage wire harness malfunction
High-voltage connector or connection malfunction
Hybrid vehicle control ECU malfunction
No. 1 traction battery device box assembly malfunction
Low voltage wire harness malfunction
Low voltage connector malfunction
INSPECTION DESCRIPTION
| System Diagram Range | Inspection Content | Reason |
|---|---|---|
| *a | Check connection condition and wire harness continuity between hybrid vehicle control ECU and No. 1 traction battery device box assembly | Check whether connectors are connected properly and check for an open circuit in the SMRP and SMRB primary lines |
| *b | Check system main relay | Check whether SMRB and SMRP stuck OFF |
| *c | Check connection condition and high-voltage cable continuity between No. 1 traction battery device box assembly and hybrid motor control inverter assembly or rear hybrid motor control inverter assembly | Check for open circuit and defective connection (arc marks) due to looseness |
| *d | Check high-voltage cable and connection condition between HV battery and No. 1 traction battery device box assembly | Check for open circuit and defective connection (arc marks) due to looseness |
| *e | Check HV battery | Check whether HV battery voltage has drastically dropped below normal range |
Refer to the description for DTC P0AE411.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE411
The hybrid vehicle control ECU monitors the high-voltage wiring between the HV battery and the hybrid motor control inverter assembly and detects the following malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge | Although a system main relay operation signal was sent when the ignition switch was operated, the system voltage is not sufficiently increased after boosting and the HV battery current does not flow.
High-voltage circuit malfunctions between the HV battery and hybrid motor control inverter assembly. The EV electric battery fuse is blown, the service plug grip is removed, the system main resistor is blown, SMRP or SMRB remains open, or the high-voltage cable has an open circuit. (2 trip detection logic) |
·
No. 1 traction battery device box assembly ·
HV floor under wire ·
Hybrid motor control inverter assembly ·
No. 1 HV supply stack sub-assembly ·
No. 2 HV supply stack sub-assembly ·
Hybrid battery terminal block ·
Electric vehicle battery plug assembly ·
Wire harness or connector ·
Rear hybrid motor control inverter assembly* ·
Hybrid battery pack wire* |
Does not come on | Master Warning: Comes on | Hybrid Control | A |
*: for AWD
| DTC No. | Data List |
|---|---|
| P300449 | ·
Hybrid/EV Battery Voltage ·
Hybrid/EV Battery Current ·
VL-Voltage before Boosting ·
VH-Voltage after Boosting |
The following items can be helpful when performing repairs:
Ready Signal
Inter Lock Switch
SMRP Status
SMRB Status
SMRG Status
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON (READY) and wait for 3 minutes or more.
According to the display on the GTS, read the Data List and monitor the values of "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" for 3 minutes. If the difference between "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" is always less than 50 V, the vehicle has returned to normal.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for DTC P0AA649.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA649
Refer to the wiring diagram for the HV battery high-voltage line circuit.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
*: for AWD
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
| *a | Dealer |
| *b | Battery Collection Agent |
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Before returning the HV battery, make sure to perform a recovery inspection.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION
Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.
After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P300449 and Microcomputer malfunction of Hybrid control system DTCs in the table below are output | A |
| P300449 and Microcomputer malfunction of Motor generator control system DTCs in the table below are output | B |
| P300449 and Microcomputer malfunction of Hybrid battery system DTCs in the table below are output | C |
| P300449 and Power source circuit malfunction of Motor generator control system DTCs in the table below are output | D |
| P300449 and Communication system malfunction of Hybrid control system DTCs in the table below are output | E |
| P300449 and Sensor and actuator circuit malfunction of Hybrid control system DTCs in the table below are output | F |
| P300449 and Sensor and actuator circuit malfunction of Hybrid battery system DTCs in the table below are output | G |
| P300449 and System malfunction of Hybrid control system DTCs in the table below are output | H |
| P300449 and System malfunction of Motor generator control system DTCs in the table below are output | I |
| P300449 and DTCs other than the DTCs in the table below are output | J |
| Only P300449 for Hybrid control system is output | K |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure | ||
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ||
| P1C9E9F | Hybrid/EV System Reset Stuck Off | ||
| P060B49 | Hybrid/EV Powertrain Control Module A/D Processing Internal Electronic Failure | ||
| Motor generator control system | P0A1B1F | Generator Control Module Circuit Intermittent | |
| P0A1A47 | Generator Control Module Watchdog / Safety MC Failure | ||
| P0A1A49 | Generator Control Module Internal Electronic Failure | ||
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
| P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
| P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | ||
| Hybrid battery system | P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message | ||
| P060B16 | Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold | ||
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance | ||
| Power source circuit malfunction | Motor generator control system | P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| Communication system malfunction | Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message | ||
| Sensor and actuator circuit malfunction | Hybrid control system | P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground | ||
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range | ||
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance | ||
| Hybrid battery system | P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground | |
| P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground | ||
| P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open | ||
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open | ||
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range | ||
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range | ||
| P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range | ||
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range | ||
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery | ||
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open | ||
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure | ||
| System malfunction | Hybrid control system | P0C7600 | Hybrid/EV Battery System Discharge Time Too Long |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | ||
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short | ||
| P1C8249 | High Voltage Power Resource Circuit Over Loading | ||
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction | ||
| P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation | ||
| Motor generator control system | P0D2D16 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold | |
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold | ||
| P1CB69E | Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On | ||
| P0CA300 | DC/DC Converter Step Up Voltage Performance | ||
P300449 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
D
E
F
G
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
H
I
J
K
Pre-procedure1
None.
Procedure1
Read the freeze frame data of DTC P300449.
| Tester Display |
|---|
| VH-Voltage after Boosting |
| Result | Proceed to |
|---|---|
| Both of the following conditions are met:
·
"VH-Voltage after Boosting" is below 50 V. ·
Difference between "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" is 35 V or less. |
A |
| None of the above conditions are met | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None.
Procedure1
Read the freeze frame data of DTC P300449.
| Tester Display |
|---|
| VH-Voltage after Boosting |
| Hybrid/EV Battery Voltage |
| Result | Proceed to |
|---|---|
| The difference between the value of Hybrid/EV Battery Voltage and VH-Voltage after Boosting is 35 or less | A |
| None of the above conditions are met | B |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA000
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA000
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the O70 No. 1 traction battery device box assembly connector.
Disconnect the H44 hybrid vehicle control ECU connector.
Procedure1
| *a | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
| *b | Front view of wire harness connector
(to No. 1 Traction Battery Device Box Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(H44,O70)Location & Routingewd_type=routing;type=c,c;code=H44,O70 Click Connector(H44)Instrument Panel>Instrument Panel Wire / Speaker Wire>Hybrid Vehicle Control ECUewd_type=component;type=c;code=H44;pinno=2,16 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=1,2 |
||
| H44-2 (SMRB) - O70-1 (SMRB) | Ignition switch off | Below 1 Ω |
| H44-16 (SMRP) - O70-2 (SMRP) | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the H44 hybrid vehicle control ECU connector.
Reconnect the O70 No. 1 traction battery device box assembly connector.
Install the HV battery upper cover panel.
OK
NG
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for 2WD | A |
| for AWD | B |
A
B
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the O70 No. 1 traction battery device box assembly connector.
Procedure1
| *a | Front view of wire harness connector
(to No. 1 Traction Battery Device Box Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=3 |
||
| O70-3 (GND) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the O70 No. 1 traction battery device box assembly connector.
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z10,a1)Location & Routingewd_type=routing;type=c,c;code=z10,a1 Click Connector(z10)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z10;pinno=1 Click Connector(a1)Body>HV Floor Under Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=a1;pinno=1 |
||
| z10-1 (+) - a1-1 (CBI) | Auxiliary battery voltage applied between terminals O70-1 (SMRB) and O70-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=1,3 |
||
| O70-1 (SMRB) - O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 19.0 to 59.0 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the No. 1 traction battery device box assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z9,a2)Location & Routingewd_type=routing;type=c,c;code=z9,a2 Click Connector(z9)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z9;pinno=1 Click Connector(a2)Body>HV Floor Under Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=a2;pinno=1 |
||
| z9-1 (-) - a2-1 (CEI) | Auxiliary battery voltage applied between terminals O70-2 (SMRP) and O70-3 (GND) | 24.3 to 29.7 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=2,3 |
||
| O70-2 (SMRP) -O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 140 to 290 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the No. 1 traction battery device box assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Procedure1
Check that the bolts for the HV floor under wire is tightened to the specified torque, the HV floor under wire is connected securely, and there are no contact problems.
T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)
Disconnect the HV floor under wire from the hybrid motor control inverter assembly.
Check for arc marks on the terminals for the HV floor under wire and hybrid motor control inverter assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the HV floor under wire.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
Check that the HV floor under wire is connected securely, and there are no contact problems.
Disconnect the HV floor under wire connectors from the No. 1 traction battery device box assembly.
Check for arc marks on the terminals of the HV floor under wire and the No. 1 traction battery device box assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the HV floor under wire connectors.
Install the HV battery upper cover panel.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the HV floor under wire connectors from the No. 1 traction battery device box assembly.
Disconnect the HV floor under wire connector from the hybrid motor control inverter assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | Shield Ground | - | - |
| *a | HV Floor Under Wire
(Hybrid Motor Control Inverter Assembly Side) |
*b | HV Floor Under Wire
(No. 1 Traction Battery Device Box Assembly Side) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a3,a1,a2)Location & Routingewd_type=routing;type=c,c,c;code=a3,a1,a2 Click Connector(a3)Engine Compartment>HV Floor Under Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=a3;pinno=1,2 Click Connector(a1)Body>HV Floor Under Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=a1;pinno=1 Click Connector(a2)Body>HV Floor Under Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=a2;pinno=1 |
||
| a3-1 (CBI) - a1-1 (CBI) | Ignition switch off | Below 1 Ω |
| a3-2 (CEI) - a2-1 (CEI) | Ignition switch off | Below 1 Ω |
Be sure not to damage or deform the terminal being inspected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV floor under wire connectors.
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
Check the HV battery high voltage connector and electric vehicle battery plug connector securely, and there are no contact problems.
Disconnect the HV battery high voltage connector and electric vehicle battery plug connector from the hybrid battery terminal block.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Check for arc marks on the terminals of the HV battery high voltage connectors and No. 1 traction battery device box assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the HV battery high voltage connector and electric vehicle battery plug connector.
Install the HV battery upper cover panel.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
Check the HV battery high voltage connector and electric vehicle battery plug connector securely, and there are no contact problems.
Disconnect the HV battery high voltage connector and electric vehicle battery plug connector from the hybrid battery terminal block.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Check for arc marks on the terminals of the HV battery high voltage connectors and hybrid battery terminal block.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the HV battery high voltage connector and electric vehicle battery plug connector.
Install the HV battery upper cover panel.
A
B
C
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 hybrid battery cover sub-assembly.
Procedure1
Check that the HV battery high voltage connector is connected securely, and there are no contact problems.
Disconnect the HV battery high voltage connector.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Check for arc marks on the terminals of the HV battery high voltage connector.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Connect the HV battery high voltage connector.
Install the upper No. 1 hybrid battery cover sub-assembly.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the 2 electric vehicle battery plug assembly connectors.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Electric Vehicle Battery Plug Assembly Connector
(No. 1 Traction Battery Device Box Assembly Side) |
*b | Electric Vehicle Battery Plug Assembly Connector
(Hybrid Battery Terminal Block Side) |
| *c | Service Plug Grip Removed
(Service Plug Grip Connecting Terminals) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z8,z9)Location & Routingewd_type=routing;type=c,c;code=z8,z9 Click Connector(z8)Body>other>Hybrid Battery Terminal Block , HV Supply Battery Assemblyewd_type=component;type=c;code=z8;pinno=1 Click Connector(z9)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z9;pinno=1 |
||
| z8-1 - Service plug grip connecting terminal 1 | Ignition switch off | Below 1 Ω |
| z9-1 (-) - Service plug grip connecting terminal 2 | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the 2 electric vehicle battery plug assembly connectors.
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the HV battery high voltage connector and electric vehicle battery plug assembly connector from the hybrid battery terminal block.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Procedure1
| *a | Component without harness connected
(Hybrid Battery Terminal Block) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z8,z14)Location & Routingewd_type=routing;type=c,c;code=z8,z14 Click Connector(z8)Body>other>Hybrid Battery Terminal Block , HV Supply Battery Assemblyewd_type=component;type=c;code=z8;pinno=1 Click Connector(z14)Body>other>Hybrid Battery Terminal Block , HV Supply Battery Assemblyewd_type=component;type=c;code=z14;pinno=1 |
||
| z8-1 - z14-1 | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV battery high voltage connector and electric vehicle battery plug assembly connector.
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 hybrid battery cover sub-assembly.
Disconnect the No. 2 HV supply stack sub-assembly connector from the hybrid battery terminal block.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Disconnect the No. 2 HV supply stack sub-assembly connector.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Procedure1
| *a | No. 2 HV Supply Stack Sub-assembly Connector
(to Hybrid Battery Terminal Block) |
| *b | No. 2 HV Supply Stack Sub-assembly Connector
(to No. 1 HV Supply Stack Sub-assembly Connector) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z10)Location & Routingewd_type=routing;type=c;code=z10 Click Connector(z10)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z10;pinno=1 |
||
| z10-1 (+) - A-1 | Ignition switch off | 50 V or higher |
Do not allow the probes of the electrical tester to contact each other during this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the No. 2 HV supply stack sub-assembly connectors.
Install the upper No. 1 hybrid battery cover sub-assembly.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 hybrid battery cover sub-assembly.
Remove the electric vehicle battery plug assembly.
Disconnect the No. 1 HV supply stack sub-assembly connector from the No. 1 traction battery device box assembly.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Disconnect the No. 1 HV supply stack sub-assembly connector.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Procedure1
| *a | No. 1 HV Supply Stack Sub-assembly Connector
(to No. 1 Traction Battery Device Box Assembly) |
| *b | No. 1 HV Supply Stack Sub-assembly Connector
(to No. 2 HV Supply Stack Sub-assembly Connector) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z14)Location & Routingewd_type=routing;type=c;code=z14 Click Connector(z14)Body>other>Hybrid Battery Terminal Block , HV Supply Battery Assemblyewd_type=component;type=c;code=z14;pinno=1 |
||
| z14-1 - A-1 | Ignition switch off | 50 V or higher |
Do not allow the probes of the electrical tester to contact each other during this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the No. 2 HV supply stack sub-assembly connectors.
Install the electric vehicle battery plug assembly.
Install the upper No. 1 hybrid battery cover sub-assembly.
OK
NG
Check for intermittent problems.
| Result | Proceed to |
|---|---|
| Problem symptom does not recur. | A |
| Problem symptom recurs. | B |
Since 2 trip detection logic is used, the DTC detection condition must be met twice.
If DTC P300449 is output again after performing the inspection, replace the hybrid motor control inverter assembly. If DTC P300449 is not output again, replace the No. 1 traction battery device box assembly.
A
B
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P1C8449
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA000
| Result | Proceed to |
|---|---|
| Difference between "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" is always less than 50 V. | A |
| Difference between "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" is 50 V or more. | B |
A
B
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the O70 No. 1 traction battery device box assembly connector.
Procedure1
| *a | Front view of wire harness connector
(to No. 1 Traction Battery Device Box Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=3 |
||
| O70-3 (GND) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the O70 No. 1 traction battery device box assembly connector.
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z10,c1)Location & Routingewd_type=routing;type=c,c;code=z10,c1 Click Connector(z10)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z10;pinno=1 Click Connector(c1)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c1;pinno=1 |
||
| z10-1 (+) - c1-1 (CBI) | Auxiliary battery voltage applied between terminals O70-1 (SMRB) and O70-3 (GND) | Below 1 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=1,3 |
||
| O70-1 (SMRB) - O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 19.0 to 59.0 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the No. 1 traction battery device box assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Component without harness connected
(No. 1 Traction Battery Device Box Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z9,c2)Location & Routingewd_type=routing;type=c,c;code=z9,c2 Click Connector(z9)Body>other>HV Supply Battery Assembly , HV Battery Junction Block Assemblyewd_type=component;type=c;code=z9;pinno=1 Click Connector(c2)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c2;pinno=1 |
||
| z9-1 (-) - c2-1 (CEI) | Auxiliary battery voltage applied between terminals O70-2 (SMRP) and O70-3 (GND) | 24.3 to 29.7 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O70)Location & Routingewd_type=routing;type=c;code=O70 Click Connector(O70)Body>Floor Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=O70;pinno=2,3 |
||
| O70-2 (SMRP) -O70-3 (GND) | -40 to 80°C (-40 to 176°F) | 140 to 290 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the No. 1 traction battery device box assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Procedure1
Check that the bolts for the HV floor under wire is tightened to the specified torque, the HV floor under wire is connected securely, and there are no contact problems.
T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)
Disconnect the HV floor under wire from the hybrid motor control inverter assembly.
Check for arc marks on the terminals for the HV floor under wire and hybrid motor control inverter assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the HV floor under wire.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the rear hybrid motor control inverter assembly.
Check that the bolts for the HV floor under wire is tightened to the specified torque, the HV floor under wire is connected securely, and there are no contact problems.
T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
Disconnect the HV floor under wire from the rear hybrid motor control inverter assembly.
Procedure1
Check for arc marks on the terminals for the HV floor under wire and rear hybrid motor control inverter assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the HV floor under wire to the rear hybrid motor control inverter assembly.
Install the inverter terminal cover from the rear hybrid motor control inverter assembly.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove inverter terminal cover from the rear hybrid motor control inverter assembly.
Procedure1
Check that the bolts for the HV battery pack wire is tightened to the specified torque, the HV battery pack wire is connected securely, and there are no contact problems.
T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
Disconnect the HV battery pack wire from the rear hybrid motor control inverter assembly.
Check for arc marks on the terminals for the HV battery pack wire and rear hybrid motor control inverter assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the HV battery pack wire to the rear hybrid motor control inverter assembly.
Install the inverter terminal cover from the rear hybrid motor control inverter assembly.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Procedure1
Check that the HV battery pack wire is connected securely, and there are no contact problems.
Disconnect the HV battery pack wire connectors from the No. 1 traction battery device box assembly.
Check for arc marks on the terminals of the HV battery pack wire and the No. 1 traction battery device box assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the HV battery pack wire.
Install the HV battery upper cover panel.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the HV floor under wire connectors from the No. 1 traction battery device box assembly.
Disconnect the HV floor under wire connector from the hybrid motor control inverter assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | HV Floor Under Wire
(Hybrid Motor Control Inverter Assembly Side) |
*b | HV Floor Under Wire
(No. 1 Traction Battery Device Box Assembly Side) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a3,c1,c2)Location & Routingewd_type=routing;type=c,c,c;code=a3,c1,c2 Click Connector(a3)Engine Compartment>HV Floor Under Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=a3;pinno=1,2 Click Connector(c1)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c1;pinno=1 Click Connector(c2)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c2;pinno=1 |
||
| a3-1 (CBI) - c1-1 (CBI) | Ignition switch off | Below 1 Ω |
| a3-2 (CEI) - c2-1 (CEI) | Ignition switch off | Below 1 Ω |
Be sure not to damage or deform the terminal being inspected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV floor under wire connector to the hybrid motor control inverter assembly.
Reconnect the HV floor under wire connectors to the No. 1 traction battery device box assembly.
Install the HV battery upper cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the HV floor under wire connector from the hybrid motor control inverter assembly.
Remove the inverter terminal cover from the rear hybrid motor control inverter assembly.
Disconnect HV floor under wire connector from the rear hybrid motor control inverter assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | Shield Ground | - | - |
| *a | HV Floor Under Wire
(Hybrid Motor Control Inverter Assembly Side) |
*b | HV Floor Under Wire
(Rear Hybrid Motor Control Inverter Assembly Side) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(a3,a4)Location & Routingewd_type=routing;type=c,c;code=a3,a4 Click Connector(a3)Engine Compartment>HV Floor Under Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=a3;pinno=1,2 Click Connector(a4)Body>HV Floor Under Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=a4;pinno=2,1 |
||
| a3-1 (CBI) - a4-2 (RCBO) | Ignition switch off | Below 1 Ω |
| a3-2 (CEI) - a4-1 (RCEO) | Ignition switch off | Below 1 Ω |
Be sure not to damage or deform the terminal being inspected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV floor under wire connector to the hybrid motor control inverter assembly.
Install the inverter terminal cover to the rear hybrid motor control inverter assembly.
Reconnect HV floor under wire connector from the rear hybrid motor control inverter assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the HV battery upper cover panel.
Disconnect the HV battery pack wire connectors from the No. 1 traction battery device box assembly.
Remove the inverter terminal cover from the rear hybrid motor control inverter assembly.
Disconnect the HV battery pack wire from the rear hybrid motor control inverter assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | Shield Ground | - | - |
| *a | HV Battery Pack Wire
(Rear Hybrid Motor Control Inverter Assembly Side) |
*b | HV Battery Pack Wire
(Hybrid Battery Junction Clock Assembly Side) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(c6,c1,c2)Location & Routingewd_type=routing;type=c,c,c;code=c6,c1,c2 Click Connector(c6)Body>HV Battey Pack Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=c6;pinno=1,2 Click Connector(c1)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c1;pinno=1 Click Connector(c2)Body>HV Battey Pack Wire>HV Battery Junction Block Assemblyewd_type=component;type=c;code=c2;pinno=1 |
||
| c6-1 (RCBI) - c1-1 (CBI) | Ignition switch off | Below 1 Ω |
| c6-2 (RCEI) - c2-1 (CEI) | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the HV battery pack wire to the rear hybrid motor control inverter assembly.
Install the inverter terminal cover from the rear hybrid motor control inverter assembly.
Reconnect the HV battery pack wire to the No. 1 traction battery device box assembly.
Install the HV battery upper cover panel.
OK
NG