Home › Engine / Hybrid System › FA20 ENGINE CONTROL › SFI SYSTEM

SFI SYSTEM > EVAP System

for Preparation Click here


RELATED DTCS


DTC No.
Monitoring Item
See page
P0441
Purge flow
Click here
P0451
Canister pressure sensor (built into canister pump module) signal becomes fixed/flat
Click here
P0452
Canister pressure sensor (built into canister pump module) voltage low
P0453
Canister pressure sensor (built into canister pump module) voltage high
P0455
EVAP gross leak
Click here
P0456
EVAP small leak
P0458
Purge valve voltage low
Click here
P0459
Purge valve voltage high
P1449
Air filter clogged (built into canister pump module)
Click here
P1451
Pipe clogged
Click here
P2404
  1. Reference orifice high-flow (built into canister pump module)
  2. Reference orifice low-flow (built into canister pump module)
P2401
Leak detection pump stuck OFF (built into canister pump module)
Click here
P2402
Leak detection pump stuck ON (built into canister pump module)
P2419
Vent valve stuck closed (built into canister pump module)
P2420
Vent valve stuck open (vent) (built into canister pump module)
P2610
Soak timer (built into ECM)
Click here
If any EVAP system DTCs are stored, the malfunctioning area can be determined using the table below.

A281938E01


A282300E01


DESCRIPTION


A281937E01


Text in Illustration 
*1
Purge Valve
*2
EVAP Hose (to Intake Manifold)
*3
EVAP Hose (from Charcoal Canister Assembly)
*4
Fuel Tank
*5
Canister Pump Module
- Canister Pressure Sensor
- Leak Detection Pump
- Vent Valve
- Canister filter
*6
Fuel Tank Cap Assembly
*7
Air Inlet Port
*8
Charcoal Canister Assembly
*9
Purge Line
-
-
*a
Location of EVAP (Evaporative Emission) System
-
-

HINT:
The canister pressure sensor, the canister filter, the leak detection pump and the vent valve are built into the canister pump module.


A281934E01


Text in Illustration 
*1
Intake Manifold
*2
Throttle Valve
*3
Purge Valve
*4
Cut-off Valve
*5
Fuel Tank
*6
Fuel Tank Cap Assembly
*7
Fuel Tank Vent Valve
*8
Charcoal Canister Assembly (Charcoal Filter)
*9
Canister Filter
*10
Canister Pump Module
*11
ECM
*12
Soak Timer
*13
Air Cleaner
-
-
*a
EVAP System Circuit
-
-

NOTICE:
In the EVAP system of this vehicle, turning ON the vent valve does not seal off the EVAP system. To check for leaks in the EVAP system, disconnect the air inlet drain hose and apply pressure from atmospheric side of the charcoal canister assembly.

While the engine is running, if a predetermined condition (closed-loop, etc.) is met, the purge valve is opened by the ECM and fuel vapors stored in the charcoal canister assembly are purged to the intake manifold. The ECM changes the duty cycle ratio of the purge valve to control purge flow volume.
The purge flow volume is also determined by the intake manifold pressure. Atmospheric pressure is allowed into the charcoal canister assembly through the vent valve to ensure that the purge flow is maintained when negative pressure (vacuum) is applied to the charcoal canister assembly.
The following two monitors run to confirm appropriate EVAP system operation.

Purge flow monitor
The purge flow monitor consists of the 2 monitors. The 1st monitor is conducted every time and the 2nd monitor is activated if necessary.
  1. The 1st monitor
    While the engine is running and the purge valve (Vacuum Switching Valve) is on (open), the ECM monitors the purge flow by measuring the EVAP pressure change. If the variation in the pressure is less than threshold, the ECM begins the 2nd monitor.
  2. The 2nd monitor
    The vent valve is turned ON (closed) and the EVAP pressure is then measured. If the variation in the pressure is less than threshold, the ECM interprets this as the purge valve being stuck closed, and illuminates the MIL and stores DTC P0441 (2 trip detection logic).
  1. Atmospheric pressure check:
    1. In order to ensure reliable malfunction detection, the variation between the atmospheric pressures, before and after of the purge flow monitor, is measured by the ECM.

A281932E01


Text in Illustration 
*1
ECM
*2
Soak Timer
*3
Purge Valve (on)
*4
Fuel Tank Cap Assembly
*5
Fuel Tank
*6
Canister Filter
*7
Leak Detection Pump (off)
*8
Canister Pressure Sensor
*9
Charcoal Canister Assembly
*10
Vent Valve (off)
*11
Canister Pump Module
*12
Reference Orifice (0.02 inch)
*a
EVAP Purge Flow
*b
to Intake Manifold

Component
Operation
Charcoal Canister Assembly
Contains activated charcoal to absorb EVAP (Evaporative Emissions) generated in fuel tank.
Cut-off valve
Located in fuel tank. Valve closes by its own weight when vehicle overturns to prevent fuel from spilling out.
Purge valve (Vacuum Switching Valve)
Opens or closes line between charcoal canister assembly and intake manifold. ECM uses purge valve to control EVAP purge flow. In order to discharge EVAP absorbed by charcoal canister assembly to intake manifold, ECM opens purge valve. EVAP discharge volume to intake manifold controlled by purge valve duty cycle (current-carrying time). (Open: on, Close: off)
Fuel Tank Vent Valve
Located in the fuel tank. Passes evaporative emissions occurring during fueling to the charcoal canister assembly. Additionally, this mechanism also detects when the fuel tank is full.
Soak timer
Built into ECM. To ensure accurate EVAP monitor, measures 5 hours (+/-15 min) after ignition switch is turned off. This allows fuel to cool down, stabilizing EVAP pressure. When approximately 5 hours elapsed, ECM activates (refer to fig. 3).
Canister pump module
Consists of (a) to (d) below. Canister pump module cannot be disassembled.
(a) Vent valve
Vents and closes EVAP system. When ECM turns valve on, EVAP system is closed. When ECM turns valve off, EVAP system is vented. Negative pressure (vacuum) is created in EVAP system to check for EVAP leaks by closing purge valve, turning on vent valve (closing it) and operating leak detection pump (refer to fig. 1).
(b) Canister pressure sensor
Indicates pressure as voltages. ECM supplies regulated 5 V to pressure sensor, and uses feedback from sensor to monitor EVAP system pressure (refer to fig. 2).
(c) Leak detection pump
Creates negative pressure (vacuum) in EVAP system for leak check.
(d) Reference orifice
Has opening with 0.02 inch diameter. Vacuum is produced through orifice by closing purge valve, turning off vent valve and operating leak detection pump, to monitor reference pressure. Reference pressure indicates a small leak of EVAP.

A207995E05


Text in Illustration 
*1
Canister
*2
Reference Orifice (0.02 Inch)
*3
Canister Pressure Sensor
-
-
*a
Canister Pump Module (fig. 1)
*b
Airflow
*c
Condition: Purge Flow
*d
Condition: Leak Check
*e
Vent Valve: off (vent)
*f
to Canister Filter (Atmosphere)
*g
Leak Detection Pump: off
*h
Vent Valve: on (closed)
*i
Leak Detection Pump: on
-
-

A282306E01


A281933E01


WIRING DIAGRAM

Refer to DTC P0451 .

INSPECTION PROCEDURE

NOTICE:
  1. Inspect the fuses for circuits related to this system before performing the following inspection procedure.
  2. The GTS is required to conduct the following diagnostic troubleshooting procedure.

HINT:
  1. Using the GTS monitor results enables the EVAP (Evaporative Emission) system to be confirmed.
  2. Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.CONFIRM DTC
  1. Turn the ignition switch off and wait for 10 seconds.

  1. Turn the ignition switch to ON.

  1. Turn the ignition switch off and wait for 10 seconds.

  1. Connect the GTS to the DLC3.

  1. Turn the ignition switch to ON and turn the GTS on.

  1. Enter the following menus: Powertrain / Engine / Trouble Codes.



  1. Confirm DTCs and freeze frame data.
    If any EVAP system DTCs are stored, the malfunctioning area can be determined using the table below.


    A281938E01


    A282300E01


NEXT


2.PERFORM EVAP SYSTEM CHECK (AUTOMATIC MODE)

NOTICE:
  1. The Evaporative System Check (Automatic Mode) consists of 5 steps performed automatically by the GTS. It takes a maximum of approximately 24 minutes.
  2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
  3. Do not run the engine during this operation.
  4. When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F) and the coolant temperature below 45°C (113°F).

  1. Connect the GTS to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the GTS on.

  1. Clear the DTCs (Click here).

  1. Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode.

  1. After the EVAP SYSTEM CHECK is completed, check for pending DTCs by entering the following menus: Powertrain / Engine / Trouble Codes.

    HINT:
    If no pending DTCs are displayed, perform the Confirmation Driving Pattern. After this confirmation, check for pending DTCs. If no DTCs are displayed, the EVAP system is normal.


NEXT


3.PERFORM EVAP SYSTEM CHECK (MANUAL MODE)

A281935E01

NOTICE:
  1. In the Evaporative System Check (Manual Mode), the series of 5 Evaporative System Check steps are performed manually using the GTS.
  2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
  3. Do not run the engine during this operation.
  4. When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F) and the coolant temperature below 45°C (113°F).

  1. Connect the GTS to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the GTS on.

  1. Clear the DTCs (Click here).

  1. Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Manual Mode.


NEXT


4.PERFORM EVAP SYSTEM CHECK (STEP 1/5)

A282301E01

  1. Check the EVAP pressure in step 1/5.

    Result 
    DTC
    *
    Result
    Suspected Trouble Area
    Proceed to
    -
    Virtually no variation in EVAP pressure
    Not yet determined
    A
    P2404
    EVAP pressure is less than -0.224 kPa(gauge) [2 mmHg(gauge)]
    Leak detection pump stuck OFF
    B
    *: These DTCs are already present in the ECM when the vehicle arrives and are confirmed in the "Confirm DTC" procedure above.



B
Go to step 9
A


5.PERFORM EVAP SYSTEM CHECK (STEP 2/5)

A282302E01

  1. Check the EVAP pressure in steps 2/5.

    Result 
    DTC*
    Result
    Suspected Trouble Area
    Proceed to
    -
    Virtually no variation in EVAP pressure
    Not yet determined
    A
    P2404
    EVAP pressure fluctuates by more than +/- 0.3 kPa (gauge) [2 mmHg (gauge)]
    1. Vent valve stuck close
    2. Reference orifice high-flow
    3. Reference orifice low-flow
    B
    *: These DTCs are already present in the ECM when the vehicle arrives and are confirmed in the "Confirm DTC" procedure above.

    HINT:
    The first reference pressure is the value determined in step 2/5.



B
Go to step 12
A


6.PERFORM EVAP SYSTEM CHECK (STEP 3/5)

A282303E01

  1. Check the EVAP pressure in step 3/5.

    Result 
    DTC*
    Result
    Suspected Trouble Area
    Proceed to
    -
    EVAP pressure increases by 0.2 kPa (gauge) [2 mmHg (gauge)] or more within 12 seconds.
    Not yet determined
    A
    P2404
    1. EVAP pressure increases by less than 0.2 kPa (gauge) [2 mmHg (gauge)] within 12 seconds.
    2. Virtually no variation in EVAP pressure
    Vent valve stuck open
    B
    *: These DTCs are already present in the ECM when the vehicle arrives and are confirmed in the "Confirm DTC" procedure above.



B
Go to step 14
A


7.PERFORM EVAP SYSTEM CHECK (STEP 4/5)

A282304E01

  1. Check the EVAP pressure in step 4/5.

    Result 
    DTC*
    Result
    Suspected Trouble Area
    Proceed to
    -
    EVAP pressure is more then -5 kPa (gauge) [-38 mmHg (gauge)] within 900 seconds
    Not yet determined
    A
    P1451
    EVAP pressure is reference pressure -0.9 kPa [-7 mmHg] less then -5 kPa (gauge) [-38 mmHg (gauge)] within 27 seconds
    Pipe clogged
    B
    *: These DTCs are already present in the ECM when the vehicle arrives and are confirmed in the "Confirm DTC" procedure above.



B
Go to step 18
A


8.PERFORM EVAP SYSTEM CHECK (STEP 5/5)

A282305E01

  1. Check the EVAP pressure in step 5/5.

  1. Compare the EVAP pressure in step 4/5 and the refeerence pressure (step 5/5).

    Result 
    DTC*
    Result
    Suspected Trouble Area
    Proceed to
    -
    EVAP pressure increases by 0.3 kPa (gauge) [2 mmHg (gauge)] or less within 40 seconds.
    Not yet determined
    (no leakage from EVAP system)
    A
    P0455
    EVAP pressure from step 4/5 higher than [reference pressure (step 4/5) x 0.377]
    EVAP gross leak
    B
    P0456
    EVAP pressure from step 4/5 higher than reference pressure (step D)
    EVAP small leak
    B
    *: These DTCs are already present in the ECM when the vehicle arrives and are confirmed in the "Confirm DTC" procedure above.



A
Go to step 27

B
Go to step 20

9.PERFORM ACTIVE TEST USING GTS (ACTIVATE THE VACUUM PUMP)
  1. Enter the following menus: Powertrain / Engine / Active Test / Activate the Vacuum Pump.



    A281930E01
  1. Measure the voltage according to the value(s) in the table below.
    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Canister Pump Module)

    Result 
    Tester Connection
    Condition
    Test Result
    Suspected Trouble Area
    Proceed to
    G8-4 - Body ground
    Leak detection pump on and off
    (Active Test ON and OFF)
    Approximately 0 V when OFF and ON
    Power source wire harness of leak detection pump
    A
    10 to 13 V when OFF and ON
    1. Wire harness or connector between leak detection pump and ECM
    2. ECM
    B
    10 to 13 V when OFF
    Approximately 0 V when ON
    Leak detection pump
    C



B
Go to step 11

C
Go to step 28
A


10.INSPECT CANISTER PUMP MODULE (POWER SOURCE FOR LEAK DETECTION PUMP)
  1. Turn the ignition switch off.

  1. Disconnect the canister pump module connector.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Result 
    Tester Connection
    Condition
    Test Result
    Suspected Trouble Area
    Proceed to
    G8-3 - Body ground
    Ignition switch ON
    11 to 14 V
    Canister pump module
    A
    Below 1 V
    Wire harness or connector between canister pump module and battery
    B



A
Go to step 28

B
Go to step 25

11.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM)
  1. Turn the ignition switch off.

  1. Disconnect the canister pump module connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:

    Tester Connection
    Condition
    Specified Condition
    A35-8 (MPMP) - G8-4
    Always
    Below 1 Ω
    A35-8 (MPMP) or G8-4 - Body ground
    Always
    10 kΩ or higher


    Result 
    Result
    Suspected Trouble Area
    Proceed to
    OK
    ECM
    A
    NG
    Wire harness or connector between ECM and canister pump module
    B



A
Go to step 30

B
Go to step 25

12.INSPECT CANISTER PUMP MODULE (VENT VALVE OPERATION)
  1. Turn the ignition switch off.



    A281930E01
  1. Disconnect the canister pump module connector.
    Text in Illustration 
    *a
    Component without harness connected
    (Canister Pump Module)

  1. Apply the battery voltage to terminals G8-5 and G8-1 of the canister pump module.

  1. Touch the canister pump module to confirm the vent valve operation.

    Result 
    Condition
    Tester Result
    Suspected Trouble Area
    Proceed to
    Apply battery voltage to terminals G8-5 and G8-1
    Operating
    1. Wire harness or connector between vent valve and ECM
    2. Leak detection pump performance deteriorates
    3. Leak detection pump circuit malfunctioning (large resistance exists in the circuit)
    4. ECM
    A
    Not operating
    Vent valve
    B



B
Go to step 28
A


13.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM)
  1. Turn the ignition switch off.

  1. Disconnect the canister pump module connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.


Standard Resistance (Check for Open):

Tester Connection
Condition
Specified Condition
A35-1 (VPMP) - G8-1
Always
Below 1 Ω


Standard Resistance (Check for Short):

Tester Connection
Condition
Specified Condition
A35-1 (VPMP) or G8-1 - Body ground
Always
10 kΩ or higher


Result 
Result
Suspected Trouble Area
Proceed to
OK
ECM
A
NG
Wire harness or connector between ECM and canister pump module
B


A
Go to step 30

B
Go to step 25

14.INSPECT CANISTER PUMP MODULE (POWER SOURCE FOR VENT VALVE)


    A281930E01
  1. Turn the ignition switch off.

Text in Illustration 
*a
Front view of wire harness connector
(to Canister Pump Module)
  1. Disconnect the canister pump module connector.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Result 
    Tester Connection
    Switch Condition
    Specified Condition
    Suspected Trouble Area
    Proceed to
    G8-5 - Body ground
    Ignition switch ON
    11 to 14 V
    1. Wire harness or connector between vent valve and ECM
    2. Vent valve
    3. Charcoal canister assembly (charcoal filter inside canister) clogged
    4. ECM
    A
    Below 1 V
    Power source wire harness of vent valve
    B



B
Go to step 25
A


15.INSPECT CANISTER PUMP MODULE (VENT VALVE OPERATION)
  1. Turn the ignition switch off.



    A281930E01
  1. Disconnect the canister pump module connector.
    Text in Illustration 
    *a
    Component without harness connected
    (Canister Pump Module)

  1. Apply the battery voltage to terminals G8-5 and G8-1 of the pump module.

  1. Touch the canister pump module to confirm the vent valve operation.

    Result 
    Condition
    Tester Result
    Suspected Trouble Area
    Proceed to
    Apply battery voltage to terminals G8-5 and G8-1
    Operating
    1. Wire harness or connector between vent valve and ECM
    2. Leak detection pump performance deteriorates
    3. Leak detection pump circuit malfunctioning (large resistance exists in the circuit)
    4. ECM
    A
    Not operating
    1. Vent valve
    B



B
Go to step 28
A


16.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM)
  1. Turn the ignition switch off.

  1. Disconnect the canister pump module connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Result 
    Tester Connection
    Condition
    Test Result
    Suspected Trouble Area
    Proceed to
    A35-1 (VPMP) - G8-1
    Always
    Below 1 Ω
    1. Charcoal canister assembly (charcoal filter inside canister) clogged
    2. ECM
    A
    10 kΩ or higher
    Wire harness or connector between ECM and charcoal canister assembly pump module
    B



B
Go to step 25
A


17.INSPECT CHARCOAL CANISTER ASSEMBLY (CHARCOAL FILTER INSIDE CANISTER)
  1. Check for filter blockage in the charcoal canister assembly (Click here).

    OK:
    No blockages in the charcoal canister assembly.



OK
Go to step 30

NG
Go to step 24

18.INSPECT EVAP HOSE (CHARCOAL CANISTER ASSEMBLY - CANISTER PUMP MODULE)
  1. Check for blockages in the EVAP purge line between the charcoal canister assembly and canister pump module.

    OK:
    No blockages in the EVAP purge line between the charcoal canister assembly and canister pump module.



NG
Go to step 26
OK


19.INSPECT EVAP HOSE (CHARCOAL CANISTER ASSEMBLY - FUEL TANK)
  1. Check for blockages in the EVAP purge line between the charcoal canister assembly and fuel tank.

    OK:
    No blockages in the EVAP purge line between the charcoal canister assembly and fuel tank.



OK
Go to step 24

NG
Go to step 26

20.CHECK FUEL TANK CAP ASSEMBLY
  1. Check that the fuel tank cap assembly is correctly installed and confirm that the fuel tank cap assembly meets OEM specifications.

  1. Tighten the fuel tank cap assembly firmly (only one click sound could be heard).

    Result 
    Test Result
    Suspected Trouble Area
    Proceed to
    fuel tank cap assembly correctly installed
    -
    A
    fuel tank cap assembly loose
    1. fuel tank cap assembly improperly installed
    2. Defective fuel tank cap assembly
    3. fuel tank cap assembly does not meet OEM specifications
    B
    Defective fuel tank cap assembly
    -
    B
    No fuel tank cap assembly
    -
    C



B
Go to step 22

C
Go to step 23
A


21.LOCATE EVAP LEAK PART
  1. Check for leakage from EVAP system (hose, disconnection, cracks, etc.).

  1. Repair or replace the leak point.



NEXT
Go to step 29

22.CORRECTLY REINSTALL OR REPLACE FUEL TANK CAP ASSEMBLY

HINT:
  1. When reinstalling the fuel tank cap assembly, tighten it firmly (only one click sound could be head).
  2. When replacing the fuel tank cap assembly, use a fuel tank cap assembly that meets OEM specifications, and install it firmly.



NEXT
Go to step 29

23.REPLACE FUEL TANK CAP ASSEMBLY

HINT:
When installing the fuel tank cap assembly, tighten it firmly (only one click sound could be head).



NEXT
Go to step 29

24.REPLACE CHARCOAL CANISTER ASSEMBLY


  1. Replace the charcoal canister assembly (Click here).

    NOTICE:
    1. When replacing the charcoal canister assembly, check the canister pump module interior and related pipes for water, fuel and other liquids. If liquids are present, check for disconnections and/or cracks in the following: 1) the pipe from the air inlet port to the canister pump module; 2) the canister filter; and 3) the fuel tank vent hose.
    2. Check for filter blockage in the canister filter. if the canister filter has blockages, replace the canister pump module.


    A281929E01


    Text in Illustration 
    *1
    Fuel Tank Vent Hose
    *2
    Air Inlet Port
    *3
    Drain Hose
    *4
    Fuel Tank
    *5
    Charcoal Canister Assembly
    -
    -
    *a
    Inspection Area
    (check for disconnection and/or cracks)
    -
    -



NEXT
Go to step 29

25.REPAIR OR REPLACE HARNESS OR CONNECTOR


NEXT
Go to step 29

26.REPAIR OR REPLACE EVAP PURGE LINE (PURGE VALVE - CANISTER)


NEXT
Go to step 29

27.REPAIR OR REPLACE PARTS AND COMPONENTS INDICATED BY OUTPUT DTCS
  1. Repair the malfunctioning areas indicated by the DTCs that had been confirmed when the vehicle was brought in.



NEXT
Go to step 29

28.REPLACE CANISTER PUMP MODULE
  1. Replace the canister pump module (Click here).


NEXT


29.PERFORM EVAP SYSTEM CHECK (AUTOMATIC MODE)

NOTICE:
  1. The Evaporative System Check (Automatic Mode) consists of 5 steps performed automatically by the GTS. It takes a maximum of approximately 24 minutes.
  2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
  3. Do not run the engine in this step.
  4. When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F) and the coolant temperature below 45°C (113°F).

  1. Connect the GTS to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the GTS on.

  1. Clear the DTCs (Click here).

  1. Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode.

  1. After the Evaporative System Check is completed, check for pending DTCs by entering the following menus: Powertrain / Engine / Trouble Codes.

    Result 
    Result
    Proceed to
    EVAP system DTCs are output
    A
    No DTCs output
    (No pending DTCs output)
    B



B
END
A


30.REPLACE ECM
  1. Replace the ECM (Click here).


NEXT


31.PERFORM EVAP SYSTEM CHECK (AUTOMATIC MODE)

NOTICE:
  1. The Evaporative System Check (Automatic Mode) consists of 5 steps performed automatically by the GTS. It takes a maximum of approximately 24 minutes.
  2. Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.
  3. Do not run the engine in this step.
  4. When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F) and the coolant temperature below 45°C (113°F).

  1. Connect the GTS to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the GTS on.

  1. Clear the DTCs (Click here).

  1. Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode.

  1. After the Evaporative System Check is completed, check for pending DTCs by entering the following menus: Powertrain / Engine / Trouble Codes.

    HINT:
    If no pending DTCs are found, the repair has been successfully completed.


NEXT

END 


CONFIRMATION DRIVING PATTERN

HINT:
After a repair, check Monitor Status by performing the Key-Off Monitor Confirmation and Purge Flow Monitor Confirmation described below.


KEY-OFF MONITOR CONFIRMATION
  1. Preconditions
    The monitor will not run unless:

    1. The vehicle has been driven at 48 km/h (30 mph) or more for a total of 10 minutes or more.
    2. The fuel tank is less than 90% full.
    3. The engine coolant temperature is between 5°C and 45°C (41°F and 113°F).
    4. The intake air temperature is between 5°C and 50°C (41°F and 122°F).
    5. The vehicle remains stationary (the vehicle speed is 0 km/h [0 mph]).

  2. Monitor Conditions

    1. Allow the engine to idle for at least 5 minutes.
    2. Turn the ignition switch off and wait for 6 hours (8 or 10.5 hours).

      HINT:
      Do not start the engine until checking Monitor Status. If the engine is started, the steps described above must be repeated.

  3. Monitor Status

    1. Connect the GTS to the DLC3.
    2. Turn the ignition switch to ON.
    3. Turn the GTS on.
    4. Enter the following menus: Powertrain / Engine / Monitor / Current Monitor.
    5. Check the Monitor Status displayed on the GTS.

      HINT:
      If Incomplete is displayed, the monitor did not complete. Make sure that the preconditions have been met, and perform the Monitor Conditions again.


PURGE FLOW MONITOR CONFIRMATION (P0441)

HINT:
Perform this monitor confirmation after the Key-Off Monitor Confirmation shows Complete.

  1. Preconditions
    The monitor will not run unless:

    1. The vehicle has been driven at 60 km/h (40mph) or more for 10 minutes or more.
    2. The engine coolant temperature is 4.4°C (40°F) or higher.
    3. The intake air temperature is 4.4°C (40°F) or higher.

  2. Monitor Conditions

    1. Release the pressure from the fuel tank by removing and reinstalling the fuel tank cap assembly.
    2. Warm the engine up until the engine coolant temperature reaches more than 75°C (167°F).
    3. Increase the engine speed to 3000 rpm once.
    4. Allow the engine to idle and turn the A/C switch on for 1 minute.

  3. Monitor Status

    1. Turn the ignition switch off (if ON or if the engine is running).
    2. Connect the GTS to the DLC3.
    3. Turn the ignition switch to ON.
    4. Turn the GTS on.
    5. Enter the following menus: Powertrain / Engine / Monitor / Current Monitor.
    6. Check the Monitor Status displayed on the GTS.

      HINT:
      If Incomplete is displayed, the monitor did not complete. Make sure that the preconditions have been met, and perform the Monitor Conditions again.