SFI SYSTEM > EVAP System |
| DTC No. | Monitoring Item | See page |
| P0441 | Purge flow |
Click here
|
| P0451 | Canister pressure sensor (built into canister pump module) signal becomes fixed/flat |
Click here
|
| P0452 | Canister pressure sensor (built into canister pump module) voltage low | |
| P0453 | Canister pressure sensor (built into canister pump module) voltage high | |
| P0455 | EVAP gross leak |
Click here
|
| P0456 | EVAP small leak | |
| P0458 | Purge valve voltage low |
Click here
|
| P0459 | Purge valve voltage high | |
| P1449 | Air filter clogged (built into canister pump module) |
Click here
|
| P1451 | Pipe clogged |
Click here
|
| P2404 |
| |
| P2401 | Leak detection pump stuck OFF (built into canister pump module) |
Click here
|
| P2402 | Leak detection pump stuck ON (built into canister pump module) | |
| P2419 | Vent valve stuck closed (built into canister pump module) | |
| P2420 | Vent valve stuck open (vent) (built into canister pump module) | |
| P2610 | Soak timer (built into ECM) |
Click here
|



| *1 | Purge Valve | *2 | EVAP Hose (to Intake Manifold) |
| *3 | EVAP Hose (from Charcoal Canister Assembly) | *4 | Fuel Tank |
| *5 | Canister Pump Module - Canister Pressure Sensor - Leak Detection Pump - Vent Valve - Canister filter | *6 | Fuel Tank Cap Assembly |
| *7 | Air Inlet Port | *8 | Charcoal Canister Assembly |
| *9 | Purge Line | - | - |
| *a | Location of EVAP (Evaporative Emission) System | - | - |

| *1 | Intake Manifold | *2 | Throttle Valve |
| *3 | Purge Valve | *4 | Cut-off Valve |
| *5 | Fuel Tank | *6 | Fuel Tank Cap Assembly |
| *7 | Fuel Tank Vent Valve | *8 | Charcoal Canister Assembly (Charcoal Filter) |
| *9 | Canister Filter | *10 | Canister Pump Module |
| *11 | ECM | *12 | Soak Timer |
| *13 | Air Cleaner | - | - |
| *a | EVAP System Circuit | - | - |
| Purge flow monitor |

| *1 | ECM | *2 | Soak Timer |
| *3 | Purge Valve (on) | *4 | Fuel Tank Cap Assembly |
| *5 | Fuel Tank | *6 | Canister Filter |
| *7 | Leak Detection Pump (off) | *8 | Canister Pressure Sensor |
| *9 | Charcoal Canister Assembly | *10 | Vent Valve (off) |
| *11 | Canister Pump Module | *12 | Reference Orifice (0.02 inch) |
| *a | EVAP Purge Flow | *b | to Intake Manifold |
| Component | Operation |
| Charcoal Canister Assembly | Contains activated charcoal to absorb EVAP (Evaporative Emissions) generated in fuel tank. |
| Cut-off valve | Located in fuel tank. Valve closes by its own weight when vehicle overturns to prevent fuel from spilling out. |
| Purge valve (Vacuum Switching Valve) | Opens or closes line between charcoal canister assembly and intake manifold. ECM uses purge valve to control EVAP purge flow. In order to discharge EVAP absorbed by charcoal canister assembly to intake manifold, ECM opens purge valve. EVAP discharge volume to intake manifold controlled by purge valve duty cycle (current-carrying time). (Open: on, Close: off) |
| Fuel Tank Vent Valve | Located in the fuel tank. Passes evaporative emissions occurring during fueling to the charcoal canister assembly. Additionally, this mechanism also detects when the fuel tank is full. |
| Soak timer | Built into ECM. To ensure accurate EVAP monitor, measures 5 hours (+/-15 min) after ignition switch is turned off. This allows fuel to cool down, stabilizing EVAP pressure. When approximately 5 hours elapsed, ECM activates (refer to fig. 3). |
| Canister pump module | Consists of (a) to (d) below. Canister pump module cannot be disassembled. |
| (a) Vent valve | Vents and closes EVAP system. When ECM turns valve on, EVAP system is closed. When ECM turns valve off, EVAP system is vented. Negative pressure (vacuum) is created in EVAP system to check for EVAP leaks by closing purge valve, turning on vent valve (closing it) and operating leak detection pump (refer to fig. 1). |
| (b) Canister pressure sensor | Indicates pressure as voltages. ECM supplies regulated 5 V to pressure sensor, and uses feedback from sensor to monitor EVAP system pressure (refer to fig. 2). |
| (c) Leak detection pump | Creates negative pressure (vacuum) in EVAP system for leak check. |
| (d) Reference orifice | Has opening with 0.02 inch diameter. Vacuum is produced through orifice by closing purge valve, turning off vent valve and operating leak detection pump, to monitor reference pressure. Reference pressure indicates a small leak of EVAP. |

| *1 | Canister | *2 | Reference Orifice (0.02 Inch) |
| *3 | Canister Pressure Sensor | - | - |
| *a | Canister Pump Module (fig. 1) | *b | Airflow |
| *c | Condition: Purge Flow | *d | Condition: Leak Check |
| *e | Vent Valve: off (vent) | *f | to Canister Filter (Atmosphere) |
| *g | Leak Detection Pump: off | *h | Vent Valve: on (closed) |
| *i | Leak Detection Pump: on | - | - |


| 1.CONFIRM DTC |
Turn the ignition switch off and wait for 10 seconds.
Turn the ignition switch to ON.
Turn the ignition switch off and wait for 10 seconds.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Confirm DTCs and freeze frame data.
If any EVAP system DTCs are stored, the malfunctioning area can be determined using the table below.


| NEXT | |
| 2.PERFORM EVAP SYSTEM CHECK (AUTOMATIC MODE) |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Clear the DTCs (Click here).
Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode.
After the EVAP SYSTEM CHECK is completed, check for pending DTCs by entering the following menus: Powertrain / Engine / Trouble Codes.
| NEXT | |
| 3.PERFORM EVAP SYSTEM CHECK (MANUAL MODE) |

Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Clear the DTCs (Click here).
Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Manual Mode.
| NEXT | |
| 4.PERFORM EVAP SYSTEM CHECK (STEP 1/5) |

Check the EVAP pressure in step 1/5.
| DTC * | Result | Suspected Trouble Area | Proceed to |
| - | Virtually no variation in EVAP pressure | Not yet determined | A |
| P2404 | EVAP pressure is less than -0.224 kPa(gauge) [2 mmHg(gauge)] | Leak detection pump stuck OFF | B |
|
| ||||
| A | |
| 5.PERFORM EVAP SYSTEM CHECK (STEP 2/5) |

Check the EVAP pressure in steps 2/5.
| DTC* | Result | Suspected Trouble Area | Proceed to |
| - | Virtually no variation in EVAP pressure | Not yet determined | A |
| P2404 | EVAP pressure fluctuates by more than +/- 0.3 kPa (gauge) [2 mmHg (gauge)] |
| B |
|
| ||||
| A | |
| 6.PERFORM EVAP SYSTEM CHECK (STEP 3/5) |

Check the EVAP pressure in step 3/5.
| DTC* | Result | Suspected Trouble Area | Proceed to |
| - | EVAP pressure increases by 0.2 kPa (gauge) [2 mmHg (gauge)] or more within 12 seconds. | Not yet determined | A |
| P2404 |
| Vent valve stuck open | B |
|
| ||||
| A | |
| 7.PERFORM EVAP SYSTEM CHECK (STEP 4/5) |

Check the EVAP pressure in step 4/5.
| DTC* | Result | Suspected Trouble Area | Proceed to |
| - | EVAP pressure is more then -5 kPa (gauge) [-38 mmHg (gauge)] within 900 seconds | Not yet determined | A |
| P1451 | EVAP pressure is reference pressure -0.9 kPa [-7 mmHg] less then -5 kPa (gauge) [-38 mmHg (gauge)] within 27 seconds | Pipe clogged | B |
|
| ||||
| A | |
| 8.PERFORM EVAP SYSTEM CHECK (STEP 5/5) |

Check the EVAP pressure in step 5/5.
Compare the EVAP pressure in step 4/5 and the refeerence pressure (step 5/5).
| DTC* | Result | Suspected Trouble Area | Proceed to |
| - | EVAP pressure increases by 0.3 kPa (gauge) [2 mmHg (gauge)] or less within 40 seconds. | Not yet determined (no leakage from EVAP system) | A |
| P0455 | EVAP pressure from step 4/5 higher than [reference pressure (step 4/5) x 0.377] | EVAP gross leak | B |
| P0456 | EVAP pressure from step 4/5 higher than reference pressure (step D) | EVAP small leak | B |
|
| ||||
|
| ||||
| 9.PERFORM ACTIVE TEST USING GTS (ACTIVATE THE VACUUM PUMP) |
Enter the following menus: Powertrain / Engine / Active Test / Activate the Vacuum Pump.
![]() |
Measure the voltage according to the value(s) in the table below.
| *a | Front view of wire harness connector (to Canister Pump Module) |
| Tester Connection | Condition | Test Result | Suspected Trouble Area | Proceed to |
| G8-4 - Body ground | Leak detection pump on and off (Active Test ON and OFF) | Approximately 0 V when OFF and ON | Power source wire harness of leak detection pump | A |
| 10 to 13 V when OFF and ON |
| B | ||
| 10 to 13 V when OFF Approximately 0 V when ON | Leak detection pump | C |
|
| ||||
|
| ||||
| A | |
| 10.INSPECT CANISTER PUMP MODULE (POWER SOURCE FOR LEAK DETECTION PUMP) |
Turn the ignition switch off.
Disconnect the canister pump module connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Test Result | Suspected Trouble Area | Proceed to |
| G8-3 - Body ground | Ignition switch ON | 11 to 14 V | Canister pump module | A |
| Below 1 V | Wire harness or connector between canister pump module and battery | B |
|
| ||||
|
| ||||
| 11.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
Turn the ignition switch off.
Disconnect the canister pump module connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A35-8 (MPMP) - G8-4 | Always | Below 1 Ω |
| A35-8 (MPMP) or G8-4 - Body ground | Always | 10 kΩ or higher |
| Result | Suspected Trouble Area | Proceed to |
| OK | ECM | A |
| NG | Wire harness or connector between ECM and canister pump module | B |
|
| ||||
|
| ||||
| 12.INSPECT CANISTER PUMP MODULE (VENT VALVE OPERATION) |
Turn the ignition switch off.
![]() |
Disconnect the canister pump module connector.
| *a | Component without harness connected (Canister Pump Module) |
Apply the battery voltage to terminals G8-5 and G8-1 of the canister pump module.
Touch the canister pump module to confirm the vent valve operation.
| Condition | Tester Result | Suspected Trouble Area | Proceed to |
| Apply battery voltage to terminals G8-5 and G8-1 | Operating |
| A |
| Not operating | Vent valve | B |
|
| ||||
| A | |
| 13.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
Turn the ignition switch off.
Disconnect the canister pump module connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A35-1 (VPMP) - G8-1 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| A35-1 (VPMP) or G8-1 - Body ground | Always | 10 kΩ or higher |
| Result | Suspected Trouble Area | Proceed to |
| OK | ECM | A |
| NG | Wire harness or connector between ECM and canister pump module | B |
|
| ||||
|
| ||||
| 14.INSPECT CANISTER PUMP MODULE (POWER SOURCE FOR VENT VALVE) |
![]() |
Turn the ignition switch off.
| *a | Front view of wire harness connector (to Canister Pump Module) |
Disconnect the canister pump module connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition | Suspected Trouble Area | Proceed to |
| G8-5 - Body ground | Ignition switch ON | 11 to 14 V |
| A |
| Below 1 V | Power source wire harness of vent valve | B |
|
| ||||
| A | |
| 15.INSPECT CANISTER PUMP MODULE (VENT VALVE OPERATION) |
Turn the ignition switch off.
![]() |
Disconnect the canister pump module connector.
| *a | Component without harness connected (Canister Pump Module) |
Apply the battery voltage to terminals G8-5 and G8-1 of the pump module.
Touch the canister pump module to confirm the vent valve operation.
| Condition | Tester Result | Suspected Trouble Area | Proceed to |
| Apply battery voltage to terminals G8-5 and G8-1 | Operating |
| A |
| Not operating |
| B |
|
| ||||
| A | |
| 16.CHECK HARNESS AND CONNECTOR (CANISTER PUMP MODULE - ECM) |
Turn the ignition switch off.
Disconnect the canister pump module connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Test Result | Suspected Trouble Area | Proceed to |
| A35-1 (VPMP) - G8-1 | Always | Below 1 Ω |
| A |
| 10 kΩ or higher | Wire harness or connector between ECM and charcoal canister assembly pump module | B |
|
| ||||
| A | |
| 17.INSPECT CHARCOAL CANISTER ASSEMBLY (CHARCOAL FILTER INSIDE CANISTER) |
Check for filter blockage in the charcoal canister assembly (Click here).
|
| ||||
|
| ||||
| 18.INSPECT EVAP HOSE (CHARCOAL CANISTER ASSEMBLY - CANISTER PUMP MODULE) |
Check for blockages in the EVAP purge line between the charcoal canister assembly and canister pump module.
|
| ||||
| OK | |
| 19.INSPECT EVAP HOSE (CHARCOAL CANISTER ASSEMBLY - FUEL TANK) |
Check for blockages in the EVAP purge line between the charcoal canister assembly and fuel tank.
|
| ||||
|
| ||||
| 20.CHECK FUEL TANK CAP ASSEMBLY |
Check that the fuel tank cap assembly is correctly installed and confirm that the fuel tank cap assembly meets OEM specifications.
Tighten the fuel tank cap assembly firmly (only one click sound could be heard).
| Test Result | Suspected Trouble Area | Proceed to |
| fuel tank cap assembly correctly installed | - | A |
| fuel tank cap assembly loose |
| B |
| Defective fuel tank cap assembly | - | B |
| No fuel tank cap assembly | - | C |
|
| ||||
|
| ||||
| A | |
| 21.LOCATE EVAP LEAK PART |
Check for leakage from EVAP system (hose, disconnection, cracks, etc.).
Repair or replace the leak point.
|
| ||||
| 22.CORRECTLY REINSTALL OR REPLACE FUEL TANK CAP ASSEMBLY |
|
| ||||
| 23.REPLACE FUEL TANK CAP ASSEMBLY |
|
| ||||
| 24.REPLACE CHARCOAL CANISTER ASSEMBLY |
Replace the charcoal canister assembly (Click here).

| *1 | Fuel Tank Vent Hose | *2 | Air Inlet Port |
| *3 | Drain Hose | *4 | Fuel Tank |
| *5 | Charcoal Canister Assembly | - | - |
| *a | Inspection Area (check for disconnection and/or cracks) | - | - |
|
| ||||
| 25.REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
| ||||
| 26.REPAIR OR REPLACE EVAP PURGE LINE (PURGE VALVE - CANISTER) |
|
| ||||
| 27.REPAIR OR REPLACE PARTS AND COMPONENTS INDICATED BY OUTPUT DTCS |
Repair the malfunctioning areas indicated by the DTCs that had been confirmed when the vehicle was brought in.
|
| ||||
| 28.REPLACE CANISTER PUMP MODULE |
Replace the canister pump module (Click here).
| NEXT | |
| 29.PERFORM EVAP SYSTEM CHECK (AUTOMATIC MODE) |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Clear the DTCs (Click here).
Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode.
After the Evaporative System Check is completed, check for pending DTCs by entering the following menus: Powertrain / Engine / Trouble Codes.
| Result | Proceed to |
| EVAP system DTCs are output | A |
| No DTCs output (No pending DTCs output) | B |
|
| ||||
| A | |
| 30.REPLACE ECM |
Replace the ECM (Click here).
| NEXT | |
| 31.PERFORM EVAP SYSTEM CHECK (AUTOMATIC MODE) |
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Clear the DTCs (Click here).
Enter the following menus: Powertrain / Engine / Utility / Evaporative System Check / Automatic Mode.
After the Evaporative System Check is completed, check for pending DTCs by entering the following menus: Powertrain / Engine / Trouble Codes.
| NEXT | ||
| ||
| KEY-OFF MONITOR CONFIRMATION |
Preconditions
The monitor will not run unless:
Monitor Conditions
Monitor Status
| PURGE FLOW MONITOR CONFIRMATION (P0441) |
Preconditions
The monitor will not run unless:
Monitor Conditions
Monitor Status