Home › Drivetrain › K313 (MULTIDRIVE / CVT) › PARK / NEUTRAL POSITION SWITCH › from 2020.08
RM32H0E _52 Drivetrain _059624 K313 MULTIDRIVE / CVT _0299313 PARK / NEUTRAL POSITION SWITCH A

K313 MULTIDRIVE / CVT  PARK / NEUTRAL POSITION SWITCH  INSTALLATION  


PROCEDURE

Hide 84540 1.INSTALL PARK/NEUTRAL POSITION SWITCH

a.

Temporarily install the park/neutral position switch to the continuously variable transaxle with the 2 bolts.


b.

Install the lock nut and lock plate to the park/neutral position switch.

Torque:
6.9 N*m (70 kgf*cm, 61 in.*lbf)


c.
C310228N01
2.917,0.656 3.188,0.854 0.271,0.198 10 true P 2.583,0.115 2.813,0.281 0.229,0.167 10 true N

Temporarily install the control shaft lever.


d.

Turn the control shaft lever clockwise until it stops, and then from that position turn it counterclockwise by 2 notches to set it to the N position.


e.

Remove the control shaft lever.


f.
C154976C08
1.542,0.146 1.656,0.146 1.656,0.146 2,1.188 true 1.74,1.198 2.094,1.938 2.094,1.938 2.198,1.938 true 1.354,0.031 1.625,0.26 0.271,0.229 10 false *a 2.271,1.854 2.5,2.052 0.229,0.198 10 false *b
*a Neutral Basic Line
*b Protrusion


Align the protrusion with the neutral basic line.


g.

Hold the park/neutral position switch in that position and tighten the 2 bolts.

Torque:
5.4 N*m (55 kgf*cm, 48 in.*lbf)


h.
C154977

Using a screwdriver, bend down the tabs of the lock plate.


i.

Install the control shaft lever to the continuously variable transaxle assembly with the nut and washer.

Torque:
12.7 N*m (130 kgf*cm, 9 ft.*lbf)


j.

Connect the park/neutral position switch connector.


Hide 33820B 2.CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY

a.

Connect the transmission control cable assembly to the No. 1 transmission control cable bracket with a new clip.


b.

Connect the transmission control cable assembly to the control shaft lever with the nut.

Torque:
12 N*m (122 kgf*cm, 9 ft.*lbf)

NOTICE:

Before connecting the transmission control cable assembly, check that the park/neutral position switch and shift lever are in neutral.



Hide 17701 5.INSTALL AIR CLEANER CASE SUB-ASSEMBLY

Hide 17705 6.INSTALL AIR CLEANER CAP SUB-ASSEMBLY

Hide 17751 7.INSTALL NO. 1 AIR CLEANER INLET

Hide 53141F 8.INSTALL RADIATOR COVER

Hide 28800 9.INSTALL BATTERY

Hide 10.CONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

Hide 84540 13.INSPECT PARK/NEUTRAL POSITION SWITCH

Hide 84540 14.ADJUST PARK/NEUTRAL POSITION SWITCH

Hide 15. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART