Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HV BATTERY
RM2040EQ _51 Engine / Hybrid System _014692 HYBRID / BATTERY CONTROL _0074890 HV BATTERY N

HYBRID / BATTERY CONTROL  HV BATTERY  CHARGING  


PROCEDURE

Hide 1.INSPECT AUXILIARY BATTERY VOLTAGE

a.

Measure the voltage between the terminals of the auxiliary battery.

Standard voltage:

Approximately 11 V or more


HINT:
·

The horn should sound clearly.

·

If the voltage is 10 V or less, either charge the auxiliary battery (charging usually takes about 1 hour), or replace it with an auxiliary battery that is already charged.




b.

Check the charge level of the HV battery.

i.
A275163

Check whether the HV battery warning message is shown in the multi-information display.


ii.

Confirm if the engine starts. If the engine starts, leave it idling with park (P) selected until the engine stops (self charge has completed).

If the engine cannot start, follow the procedure and charge the HV battery.

HINT:
·

Before performing external charging, always use the intelligent tester to perform troubleshooting.

·

Charging time using the THS charger is 10 minutes per charge cycle. The charging time when using a THS charger is a short charging time (when the battery temperature is 25°C (77°F), 10 minutes may be sufficient, if the battery temperature is 0°C (32°F), then three 10 minute charge cycles may be required) for putting the engine in a condition where it can be started (the system can enter the READY-on state). (The THS charger will automatically stop 10 minutes after charging starts.)





Hide 2. PREPARATION FOR HV BATTERY CHARGING

CAUTION:
·

Wear insulated gloves when working on the high voltage system.

·

After removing the service plug grip, do not turn the power switch on (READY) as this may cause a malfunction.

·

After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high voltage system.

·

After removing the service plug grip, wait 10 minutes before touching any of the high voltage connectors or terminals.



HINT:
·

Removing the service plug grip interrupts the high voltage circuit.

·

High voltage wiring connectors are orange.




b.

Remove the cool air intake duct seal.

Click hereVehicle Exterior>EXTERIOR PANELS / TRIM>RADIATOR GRILLE>REMOVAL


c.

Remove the inlet air cleaner assembly.

Click hereEngine / Hybrid System>2AR-FXE ENGINE MECHANICAL>ENGINE ASSEMBLY>REMOVAL


d.

Remove the air cleaner cap sub-assembly.

Click hereEngine / Hybrid System>2AR-FXE ENGINE CONTROL>THROTTLE BODY>REMOVAL


e.

Remove the air cleaner filter element sub-assembly.


f.

Remove the air cleaner case sub-assembly.

Click hereEngine / Hybrid System>2AR-FXE ENGINE MECHANICAL>ENGINE ASSEMBLY>REMOVAL


g.
A258734

Remove the 2 bolts and connector cover assembly.

NOTICE:

Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the cover.




i.
A258752

Remove the bolt.


j.
A258753

Disconnect the wire harness clamp and connector.


k.
A256820

Measure the resistance according to the value(s) in the table below.

HINT:

If the shield line of the No. 4 floor wire is not securely connected to body ground, the THS charger will not operate. The "FAULT" and "CABLE CONNECTION" warning lights will illuminate on the THS charger.


Standard Resistance:
Tester Connection Condition Specified Condition
No. 4 floor wire connector housing - Body ground Always Below 1 Ω



l.
A256821

If the result is not as specified, inspect the connection shown in the illustration for proper installation.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>INSTALLATION


m.
A258734

Temporarily install the connector cover assembly with the 2 bolts to prevent any foreign objects or water from entering the inverter with converter assembly.


n.

Connect the THS charger in the order shown by the circled numbers in the illustration.

A268754C02
1.406,1.031 0.281,1.031 false 5.552,3.375 6.26,2.396 6.26,2.396 6.438,2.396 false 4.906,4.646 4.813,4.646 4.813,4.646 4.24,4.26 false 5.063,5.677 5.802,5.094 5.802,5.094 6.24,5.094 false 4.604,5.688 4.052,4.969 4.052,4.969 3.906,4.969 false 4.469,6.042 2.76,6.042 false 3.417,7.229 2.969,7.229 false 1.354,1.354 1.094,2.094 1.094,2.094 1.052,2.094 false 1.198,5.531 1.427,5.531 1.427,5.531 1.906,4.865 false 3.396,7.063 3.229,6.885 3.229,6.885 3,6.885 false 4.5,1.052 5.854,0.979 5.854,0.979 6.458,0.979 false 5.469,1.354 6.156,1.302 6.156,1.302 6.458,1.302 false 5.74,7.021 6.021,6.75 6.021,6.75 6.281,6.75 false 6.688,1.24 6.906,1.448 0.219,0.208 10 false *1 6.677,0.885 6.896,1.094 0.219,0.208 10 false *2 0.688,2.021 0.906,2.229 0.219,0.208 10 false *3 6.458,2.354 6.677,2.563 0.219,0.208 10 false *4 4.927,4.604 5.146,4.813 0.219,0.208 10 false *5 2.354,5.917 2.573,6.125 0.219,0.208 10 false *7 1.042,5.458 1.26,5.667 0.219,0.208 10 false *6 6.302,6.656 6.521,6.865 0.219,0.208 10 false *9 3.552,4.865 3.771,5.073 0.219,0.208 10 false *3 6.448,4.99 6.667,5.198 0.219,0.208 10 false *2 0.042,0.969 0.333,1.177 0.292,0.208 10 false *10 2.833,6.792 3.052,7 0.219,0.208 10 false *8
*1 EV Bonding Cable (Green Cable) *2 Low Voltage Cable
*3 High Voltage Cable *4 HV Battery
*5 No. 4 floor wire *6 Inverter with Converter Assembly
*7 EV Bonding Cable *8 Grounded AC 100 to 240 V Receptacle
*9 THS Charger *10 Bolt (91553-80665)


SST
09880-10021  (09881-10041)
09881-10120  
09882-10040  
09882-10070  

NOTICE:
·

Make sure to connect the EV bonding cable first to prevent electrical shock.

·

Connect all THS charger cables in the order shown in the illustration to prevent electrical shock.




o.
A256818

Connect the EV bonding cable to the installation bolt of the No. 5 inverter bracket.

Torque:
8.5 N*m (87 kgf*cm, 75 in.*lbf)


p.
A208147

Connect the EV bonding cable to the THS charger.


q.
A256819

Connect the low voltage cable to the positions shown in the illustration, and then tighten the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


r.
A255155

Connect the No. 4 floor wire to the high voltage cable with the bolt (91553-80665).

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

The installation bolt that comes with the vehicle is too short to securely connect the No. 4 floor wire to the high voltage cable of the charger.

·

Do not use the bolt (91553-80665) used for connecting the high voltage cable when reconnecting the No. 4 floor wire to the vehicle.



HINT:

When connecting the high voltage cable, use a bolt with a nominal diameter of 6 mm, a shaft length of 69 mm and a pitch of 1.0 mm.



s.
A238368C02
3.125,0.469 3.333,0.656 0.208,0.188 10 false *1 0.323,2.417 0.531,2.604 0.208,0.188 10 false *2
*1 Low Voltage Cable
*2 High Voltage Cable


Connect the low voltage cable and high voltage cable to the THS charger in the order shown in the illustration.



u.

Connect the negative auxiliary battery terminal.


v.

Connect the power input plug of the charger to a grounded AC 100 to 240 V receptacle.

NOTICE:

Always use an AC 100 to 240 V receptacle with a properly functioning ground. The ground is designed to reduce the chance of electric shock if a malfunction occurs. Do not use the charger if any of the pins on its plug have been damaged or removed.



Hide 3. HV BATTERY CHARGING

a.

Turn the power switch of the vehicle on (IG).


b.

Connect the intelligent tester to the DLC3.


c.

Enter the following menus: Powertrain / Hybrid Control / Active Test / Battery Charge.

Powertrain > Hybrid Control > Active Test
Tester Display
Battery Charge
50004 236 3
HINT:
·

During the "Battery Charge" Active Test, check "System Main Relay Status - SMRB" and "System Main Relay Status - SMRG" in the Data List.

·

If the Data List values are not as specified in the table below, turn the intelligent tester and the power switch off and then perform the Charge Battery procedure again.



"SMRB" and "SMRG" in Data List during "Battery Charge" Active Test:
Step Active Test
Battery Charge
THS charger START
switch
Data List
System Main Relay Status - SMRB
Data List
System Main Relay Status - SMRG
1 OFF OFF OFF OFF
2 OFF → ON OFF OFF → ON OFF → ON
3 ON OFF → ON ON ON



d.

Make sure that the EMERGENCY STOP switch is in the reset condition (the switch is turned clockwise and released).


e.

Make sure that the BREAKER is in the ON position.


f.
A208150

Turn the THS charger MAIN switch on.

HINT:

The MAIN indicator will illuminate green.



g.

Press the START switch.

A208151

HINT:
·

When the START switch is turned on, the INITIAL CHECK indicator illuminates and an initial check starts. When the initial check completes successfully, the INITIAL CHECK indicator turns off, the CHARGING indicator illuminates and charging will start at the same time.

·

While the INITIAL CHECK indicator is illuminated, the insulation, 400 V output, emergency stop switch, connector connections and ground connection are inspected.




h.

Repeat the charge cycle 3 times. When the last cycle has finished, turn the THS charger MAIN switch off.

HINT:
·

Charging time using the THS charger is 10 minutes per charge cycle. The charging time when using a THS charger is a short charging time (when the battery temperature is 25°C (77°F), 10 minutes may be sufficient, if the battery temperature is 0°C (32°F), then three 10 minute charge cycles may be required) for putting the engine in a condition where it can be started (the system can enter the READY-on state). (The THS charger will automatically stop 10 minutes after charging starts.)

·

There is very little chance of overcharging the HV battery during the second or third charging cycle. The SOC will not likely increase beyond the upper limit because it was low enough to prevent the engine from starting. Even if the SOC was to increase enough to exceed the limit, the hybrid vehicle control ECU will stop the active test to prevent overcharging.

·

Cranking the engine once causes the SOC to drop approximately 1%.

·

Charging the HV battery once (10 minutes) using the THS charger restores the SOC approximately 2%.




i.

Turn the power switch off.


j.

Remove the THS charger and install the No. 4 floor wire.

NOTICE:

Make sure to disconnect the EV bonding cable last.


i.

Disconnect the power inlet plug of the charger from the receptacle.


ii.

Disconnect the negative terminal of the auxiliary battery.



iv.
A238369C02
3.135,0.469 3.323,0.667 0.188,0.198 10 false *1 0.302,2.396 0.49,2.594 0.188,0.198 10 false *2
*1 Low Voltage Cable
*2 High Voltage Cable


Disconnect the high voltage cable and low voltage cable from the THS charger in the order shown in the illustration.


v.
A255155

Remove the bolt (91553-80665) and disconnect the high voltage cable from the No. 4 floor wire.

NOTICE:

Do not use the bolt (91553-80665) used for connecting the high voltage cable when reconnecting the No. 4 floor wire to the vehicle.



vi.
A256819

Remove the 2 bolts and disconnect the low voltage cable.


vii.
A208147

Disconnect the EV bonding cable from the THS charger.


viii.
A256818

Disconnect the EV bonding cable from the installation bolt of the No. 5 inverter bracket.


ix.

Tighten the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


x.

Remove the connector cover assembly.


xi.
A258753

Connect the wire harness clamp and connector.


xii.
A258752

Connect the No. 4 floor wire with the bolt.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:

Do not use the bolt (91553-80665) used for connecting the high voltage cable of the charger.



xiii.

Install the connector cover assembly with the 2 bolts.

NOTICE:

Make sure that the interlock is fully engaged.


Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


xiv.

Install the air cleaner case sub-assembly.

Click hereEngine / Hybrid System>2AR-FXE ENGINE MECHANICAL>ENGINE ASSEMBLY>INSTALLATION


xv.

Install the air cleaner filter element sub-assembly.


xvi.

Install the air cleaner cap sub-assembly.

Click hereEngine / Hybrid System>2AR-FXE ENGINE CONTROL>THROTTLE BODY>INSTALLATION


xvii.

Install the inlet air cleaner assembly.

Click hereEngine / Hybrid System>2AR-FXE ENGINE MECHANICAL>ENGINE ASSEMBLY>INSTALLATION


xviii.

Install the cool air intake duct seal.

Click hereVehicle Exterior>EXTERIOR PANELS / TRIM>RADIATOR GRILLE>INSTALLATION




k.

Check if the engine starts.

HINT:

If the engine does not start, perform the HV battery charging operation again.



Hide 4. CHECK HV BATTERY AFTER HV BATTERY CHARGE

a.

Check for DTCs.


b.

Perform the self-charging operation.

i.

Start the engine and leave park (P) selected until the engine stops idling.

HINT:

When the engine stops idling, this indicates that self-charging is complete. Perform any initialization required after the negative terminal of the auxiliary battery is disconnected and reconnected.