DTC C1256/57 Accumulator Low Pressure |
| DTC Code | INF Code | DTC Detection Condition | Trouble Area |
| C1256/57 | 141 | Either of the following is detected:
|
|
| ↑ | 143 | Any of the following is detected:
| ↑ |
| 1.BRAKE PROBLEM CHECK |
Ask the customer if frequent braking was performed while the brake warning light / yellow (minor malfunction) was on.
| Result | Proceed to |
| Frequent braking was performed | A |
| Frequent braking was not performed | B |
|
| ||||
| A | |
| 2.INSPECT BRAKE BOOSTER PUMP |
![]() |
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
Disconnect the brake booster pump connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B2 (BM1) - B4 (GND1) | Always | Below 10 Ω |
| A2 (BM2) - B4 (GND1) | Always | Below 10 Ω |
| B2 (BM1) - A2 (BM2) | Always | Below 1 Ω |
| B4 (GND1) - A1 (GND2) | Always | Below 1 Ω |
| B2 (BM1) - B1 (MTT) | Always | 950 to 1050 Ω |
| A2 (BM2) - B1 (MTT) | Always | 950 to 1050 Ω |
|
| ||||
| OK | |
| 3.READ VALUE USING TECHSTREAM (ACCUMULATOR PRESSURE SENSOR) |
Reconnect the brake booster pump connectors.
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the Data List mode on the Techstream (Click here).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Accumulator Sensor | Accumulator pressure sensor / min.: 0 V, max.: 5 V | Specified value: 3.3 to 4.7 V | - |
Depress the brake pedal 4 or 5 times to operate the pump motor, and check the output value on the Techstream with the motor stopped (not braking).
|
| ||||
| OK | |
| 4.RECONFIRM DTC |
Clear the DTCs (Click here).
Perform a road test.
Check if the same DTC is recorded (Click here).
| Result | Proceed to |
| DTC (C1256/57) is not output | A |
| DTC (C1256/57) is output | B |
|
| ||||
| A | ||
| ||
| 5.READ VALUE USING TECHSTREAM (PRESSURE SENSOR) |
Select the Data List mode on the Techstream (Click here).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Master Cylinder Sensor | Master cylinder pressure sensor 1 reading / min.: 0 V, max.: 5 V | When brake pedal is released: 0.3 to 0.9 V | Reading increases when brake pedal is depressed |
| Master Cylinder Sensor2 | Master cylinder pressure sensor 2 reading / min.: 0 V, max.: 5 V | When brake pedal is released: 0.3 to 0.9 V | Reading increases when brake pedal is depressed |
| FR W/C Sensor | FR wheel cylinder pressure sensor / min.: 0 V, max.: 5 V | When brake pedal is released: 0.3 to 0.9 V | - |
| FL W/C Sensor | FL wheel cylinder pressure sensor / min.: 0 V, max.: 5 V | When brake pedal is released: 0.3 to 0.9 V | - |
| RR W/C Sensor | RR wheel cylinder pressure sensor / min.: 0 V, max.: 5 V | When brake pedal is released: 0.3 to 0.9 V | - |
| RL W/C Sensor | RL wheel cylinder pressure sensor / min.: 0 V, max.: 5 V | When brake pedal is released: 0.3 to 0.9 V | - |
Select the Active Test mode on the Techstream (Click here).
| Tester Display | Test Part | Control Range | Diagnostic Note |
| ECB* Solenoid (SMC1) | Master cut solenoid (SMC1) | Solenoid ON / OFF | Operation sound of solenoid (clicking sound) can be heard |
| ECB* Solenoid (SMC2) | Master cut solenoid (SMC2) | Solenoid ON / OFF | Operation sound of solenoid (clicking sound) can be heard |
| ECB* Solenoid (SLRRL) Value Close | Linear solenoid (SLRRL) valve | Valve close ON / OFF | - |
| ECB* Solenoid (SLRRR) Value Close | Linear solenoid (SLRRR) valve | Valve close ON / OFF | - |
Perform the Active Test of the solenoid using the Techstream.

Check that the output value of each wheel cylinder does not increase.
|
| ||||
| OK | ||
| ||