| All functions of air conditioning system do not operate.
|
Harness or connector
|
-
|
| Air conditioning control assembly
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: No blower operation. (blower motor does not operate)
|
Harness or connector
|
-
|
| Blower resistor
|
|
| Air conditioning control assembly
|
|
| Blower with fan motor sub-assembly
|
|
| Air flow control: No blower control. (blower motor does not change speed)
|
Harness or connector
|
-
|
| Blower resistor
|
|
| Air conditioning control assembly
|
|
| Air flow control: Insufficient air comes out.
|
Harness or connector
|
-
|
| Blower resistor
|
|
| Air conditioning control assembly
|
|
| Blower with fan motor sub-assembly
|
|
| Temperature control: Cooling effectiveness is poor.
|
Refrigerant volume
|
|
| Refrigerant pressure
|
|
| Check refrigerant line
|
|
| No. 1 cooler expansion valve
|
|
| Compressor assembly with magnet clutch (for 1GR-FE)
|
|
| Compressor assembly with magnet clutch (for 1GD-FTV, 2GD-FTV)
|
|
| Compressor assembly with magnet clutch (for 1KD-FTV, 2KD-FTV)
|
|
| Compressor assembly with magnet clutch (for 2TR-FE)
|
|
| Compressor assembly with magnet clutch (for 5L-E)
|
|
| Magnet clutch assembly (for 1GR-FE)
|
|
| Magnet clutch assembly (for 1GD-FTV, 2GD-FTV)
|
|
| Magnet clutch assembly (for 1KD-FTV, 2KD-FTV) (w/ Magnet Clutch Assembly)
|
|
| Magnet clutch assembly (for 2TR-FE)
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: No cool air comes out.*
|
Refrigerant volume
|
|
| Refrigerant pressure
|
|
| Check refrigerant line
|
|
| Air conditioner pressure switch
|
|
| Harness or connector
|
-
|
| Evaporator temperature sensor circuit (w/ PTC Heater)
|
|
| No. 1 cooler thermistor (front evaporator temperature sensor) (w/o PTC Heater)
|
|
| Air conditioning compressor magnetic clutch circuit
|
|
| Air conditioning control assembly
|
|
| Compressor assembly with magnet clutch (for 1GR-FE)
|
|
| Compressor assembly with magnet clutch (for 1GD-FTV, 2GD-FTV)
|
|
| Compressor assembly with magnet clutch (for 1KD-FTV, 2KD-FTV)
|
|
| Compressor assembly with magnet clutch (for 2TR-FE)
|
|
| Compressor assembly with magnet clutch (for 5L-E)
|
|
| Air mix damper control sub-assembly
|
|
| Defroster damper control sub-assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM (for 1GR-FE)
|
|
| ECM (for 2TR-FE)
|
|
| ECM (for 1GD-FTV)
|
|
| ECM (for 2GD-FTV)
|
|
| ECM (for 1KD-FTV)
|
|
| ECM (for 2KD-FTV)
|
|
| ECM (for 5L-E)
|
|
| No. 1 cooler expansion valve
|
|
| No. 1 cooler evaporator (w/ Cooler System)
|
|
| Temperature control: No warm air comes out.
|
Harness or connector
|
-
|
| Ambient temperature sensor circuit (w/ PTC Heater)
|
|
| Air conditioning control assembly
|
|
| Air mix damper control sub-assembly
|
|
| Defroster damper control sub-assembly
|
|
| Heater radiator unit sub-assembly
|
|
| Temperature control: Output air is warmer or cooler than set temperature or response is slow.*
|
Refrigerant volume
|
|
| Refrigerant pressure
|
|
| Check refrigerant line
|
|
| Air conditioner pressure switch
|
|
| Harness or connector
|
-
|
| Evaporator temperature sensor circuit (w/ PTC Heater)
|
|
| No. 1 cooler thermistor (front evaporator temperature sensor) (w/o PTC Heater)
|
|
| Air conditioning compressor magnetic clutch circuit
|
|
| Air conditioning control assembly
|
|
| Air mix damper control sub-assembly
|
|
| Defroster damper control sub-assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM (for 1GR-FE)
|
|
| ECM (for 2TR-FE)
|
|
| ECM (for 1GD-FTV)
|
|
| ECM (for 2GD-FTV)
|
|
| ECM (for 1KD-FTV)
|
|
| ECM (for 2KD-FTV)
|
|
| ECM (for 5L-E)
|
|
| No. 1 cooler expansion valve
|
|
| No. 1 cooler evaporator (w/ Cooler System)
|
|
| Temperature control: No temperature control.
|
Air conditioning control assembly
|
|
| No air inlet control.
|
Air conditioning control assembly
|
|
| Engine coolant does not warm up quickly when engine is cold (PTC heater does not operate) (w/ PTC Heater).
|
CAN communication system (for LHD with Central Gateway ECU)
|
|
| CAN communication system (for LHD without Central Gateway ECU)
|
|
| CAN communication system (for RHD with Central Gateway ECU)
|
|
| CAN communication system (for RHD without Central Gateway ECU)
|
|
| Proceed to "PTC Heater Circuit"
|
|
| Viscous with magnet clutch heater assembly does not operate when heater switch assembly is pushed while engine is cold (w/ Viscous Heater).
|
CAN communication system (for LHD with Central Gateway ECU)
|
|
| CAN communication system (for LHD without Central Gateway ECU)
|
|
| Proceed to "Viscous Heater with Magnet Clutch Circuit"
|
|
| Engine idle up does not occur when idle up switch is pushed while engine is cold (w/ Idle Up Switch).
|
CAN communication system (for RHD with Central Gateway ECU)
|
|
| CAN communication system (for RHD without Central Gateway ECU)
|
|
| Proceed to "Idle Up Switch Circuit"
|
|
| ECO mode switch does not operate.
|
CAN communication system (for LHD with Central Gateway ECU)
|
|
| CAN communication system (for LHD without Central Gateway ECU)
|
|
| CAN communication system (for RHD with Central Gateway ECU)
|
|
| CAN communication system (for RHD without Central Gateway ECU)
|
|
| Meter/gauge system
|
|
| Air conditioning amplifier assembly
|
|
| Diagnostic trouble codes (DTCs) are not recorded. Set mode is cleared when ignition switch is off.
|
Air conditioning amplifier assembly
|
|