Home › Engine / Hybrid / EV System › 1GR-FE ENGINE CONTROL › SFI SYSTEM
Starter Signal Circuit
Circuit diagnosis · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
While the engine is being cranked, current flows from terminal ST1 of the ignition switch*1 or terminal STAR of the main body ECU*2 to the park/neutral position switch (for automatic transmission) or clutch start switch (for manual transmission) and also flows to terminal STA of the ECM (STA Signal). WIRING DIAGRAM
Refer to DTC P0617 (Click here ). INSPECTION PROCEDURE
1. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL)
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Read values.
Check the result when the ignition switch is turned to ON and when the engine is started.
OK:
Condition
Display (Starter Signal)
Ignition switch ON
OFF
Engine is started
ON
NG
OK
2. INSPECT STARTER RELAY (ST)
Inspect the starter relay (ST) (Click here ).
NG
REPLACE STARTER RELAY (ST)
OK
3. CHECK HARNESS AND CONNECTOR (ST RELAY - CLUTCH START SWITCH)
Disconnect the clutch start switch.
Remove the ST relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
ST relay (1) - A49-2*1
Always
Below 1 Ω
ST relay (1) - e1-2*2
Always
Below 1 Ω
Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
ST relay (1) or A49-2*1 - Body ground
Always
10 kΩ or higher
ST relay (1) or e1-2*2 - Body ground
Always
10 kΩ or higher
*1: for LHD *2: for RHD
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
4. CHECK HARNESS AND CONNECTOR (POWER SOURCE)
Remove the ST relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Condition
Specified Condition
ST relay (2) - ST relay (5)
Always
11 to 14 V
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (STARTER RELAY (ST) - BATTERY, BODY GROUND)
OK
5. INSPECT STARTER
Inspect the starter (for 1.4 kW Type) (Click here ).
Inspect the starter (for 2.0 kW Type) (Click here ).
Result
Result
Proceed to
OK
A
NG (for 1.4 kW Type)
B
NG (for 2.0 kW Type)
C
B
C
A
REPAIR OR REPLACE HARNESS OR CONNECTOR (STARTER - STARTER RELAY (ST), BATTERY)
6. INSPECT CLUTCH START SWITCH ASSEMBLY
Inspect the clutch start switch (for LHD) (Click here ).
Inspect the clutch start switch (for RHD) (Click here ).
Result
Result
Proceed to
OK
A
NG (for LHD)
B
NG (for RHD)
C
B
C
A
7. CHECK HARNESS AND CONNECTOR (CLUTCH START SWITCH - ECM)
Disconnect the clutch start switch connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
for LHD
Tester Connection
Condition
Specified Condition
A49-2 - A38-48 (STA)
Always
Below 1 Ω
for RHD
Tester Connection
Condition
Specified Condition
e1-2 - A52-48 (STA)
Always
Below 1 Ω
Standard Resistance (Check for Short):
for LHD
Tester Connection
Condition
Specified Condition
A49-2 or A38-48 (STA) - Body ground
Always
10 kΩ or higher
for RHD
Tester Connection
Condition
Specified Condition
e1-2 or A52-48 (STA) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
8. CHECK IF VEHICLE IS EQUIPPED WITH ENTRY AND START SYSTEM
Result
Result
Proceed to
w/ Entry and Start System
A
w/o Entry and Start System
B
B
A
9. REPLACE ECM
Replace the ECM (Click here ).
NEXT
10. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
Check the starter operation.
OK:
Malfunction has been repaired successfully.
NG
GO TO ENTRY AND START SYSTEM (ENGINE DOES NOT START) (Click here )
OK
11. INSPECT IGNITION SWITCH ASSEMBLY
Inspect the ignition switch assembly (Click here ).
NG
OK
12. CHECK HARNESS AND CONNECTOR (CLUTCH START SWITCH - IGNITION SWITCH)
Disconnect the clutch start switch connector.
Disconnect the ignition switch connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
for LHD
Tester Connection
Condition
Specified Condition
A49-1 - E93-3 (ST1)
Always
Below 1 Ω
for RHD
Tester Connection
Condition
Specified Condition
e1-1 - E93-3 (ST1)
Always
Below 1 Ω
Standard Resistance (Check for Short):
for LHD
Tester Connection
Condition
Specified Condition
A49-1 or E93-3 (ST1) - Body ground
Always
10 kΩ or higher
for RHD
Tester Connection
Condition
Specified Condition
e1-1 or E93-3 (ST1) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION SWITCH - BATTERY)