Home › Power Source / Network › 1UR-FE (BATTERY / CHARGING) › GENERATOR (for 130 A, 150 A Type)
RM2660E _57 Power Source / Network _052835 1UR-FE BATTERY / CHARGING _0255527 GENERATOR(for 130 A, 150 A Type) A

1UR-FE BATTERY / CHARGING  GENERATOR(for 130 A, 150 A Type)  INSTALLATION  


PROCEDURE

Hide 27020 1.INSTALL GENERATOR ASSEMBLY

a.

Install the stud bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


b.

Install the generator with the 3 bolts and nut.

Torque:
43 N*m (438 kgf*cm, 32 ft.*lbf)


c.

Connect the harness bracket to the generator with the bolt.

Torque:
31 N*m (316 kgf*cm, 23 ft.*lbf)


d.

Connect the generator wire with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


e.

Close the terminal cap.


f.

Connect the generator connector.


Hide 53782 5.INSTALL FRONT FENDER APRON TRIM PACKING A

Hide 51405A 7.INSTALL NO. 1 ENGINE UNDER COVER SUB-ASSEMBLY

Hide 53806 8.INSTALL FRONT FENDER SPLASH SHIELD SUB-ASSEMBLY LH

Hide 53805 9.INSTALL FRONT FENDER SPLASH SHIELD SUB-ASSEMBLY RH

Hide 10.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).