MALFUNCTION DESCRIPTION
The EV control ECU monitors the high-voltage wiring between the EV supply battery assembly,inverter with converter assembly and FC converter assembly and detects a power supply malfunction.
The cause of this malfunction may be one of the following:
Voltage sensor (VH, VL) malfunction
Motor generator control ECU (MG ECU) malfunction
Communication (wire harness) malfunction
Voltage sensor (FVH, FVL) malfunction
FCDC converter control ECU malfunction
Communication (wire harness) malfunction
EV supply battery assembly malfunction
No. 1 EV battery junction block assembly malfunction
Inverter with converter assembly malfunction
High-voltage wire harness malfunction
High-voltage connector or connection malfunction
FC converter assembly malfunction
EV control ECU malfunction
No. 1 EV battery junction block assembly malfunction
Low voltage wire harness malfunction
Low voltage connector malfunction
FC converter assembly malfunction
Refer to the description for DTC P0AE411.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AE411
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction | Although an SMR on request was sent when the ignition switch is operated, the voltage did not increase after boosting.
High-voltage circuit malfunctions between the EV supply battery and inverter with converter assembly. The EV fuse is blown, the service plug grip is removed, the system main resistor is blown, SMRP or SMRB remains open, or the high-voltage cable has an open circuit. (2 trip detection logic) |
·
Inverter with converter assembly ·
No. 1 EV battery junction block assembly ·
Floor under wire ·
EV control ECU ·
EV battery terminal block ·
No. 1 EV supply stack sub-assembly ·
No. 2 EV supply stack sub-assembly ·
FC converter assembly ·
FC junction cable ·
FC stack main relay (FRB) ·
FC stack main relay (FRG) ·
FC precharge junction assembly (FRP) ·
No. 1 FC converter wire ·
No. 2 FC converter wire ·
FC converter power module transistor ·
FCDC converter control ECU board sub-assembly |
Master Warning:
Comes on |
EV | A |
| DTC No. | Data List |
|---|---|
| P1C8349 | ·
Hybrid/EV Battery Voltage ·
Hybrid/EV Battery Current ·
VL-Voltage before Boosting ·
VH-Voltage after Boosting ·
FCDC Input Voltage ·
FCDC Output Voltage |
The following items can be helpful when performing repairs:
Ready Signal
Inter Lock Switch
SMRP Status
SMRB Status
SMRG Status
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 10 minutes or more.
Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
Turn the ignition switch off and wait for 10 minutes or more.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for DTC P0AA649.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA649
Refer to the wiring diagram for the HV battery high-voltage line circuit.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FCconverter power outlet cable on FCconverter side.
Make sure to remove the service plug gripfirst.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and FC converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
| *a | Dealer |
| *b | Battery Collection Agent |
When disposing of an EV supply battery assembly, make sure to return it through an authorized collection agent who is capable of handling it safely. If the EV supply battery assembly is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Accidents such as electric shock may result if the EV supply battery assembly or the EV supply stack sub-assembly is disposed of improperly or abandoned.
Therefore, make sure to return EV supply battery assembly and all EV supply stack sub-assemblies through an authorized collection agent.
Before returning the EV supply battery assembly, make sure to perform a recovery inspection.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION
Before returning the EV supply stack sub-assembly, make sure to perform a recovery inspection.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK>RECOVERY INSPECTION
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the EV supply battery assembly and EV supply stack sub-assemblies.
After removing the EV supply battery assembly or the EV supply stack sub-assembly, keep it away from water. Exposure to water may cause the EV supply battery assembly or the EV supply stack sub-assembly to produce heat, resulting in a fire.
Since high voltage accumulates within the FC stack assembly with FC converter, never perform the work of separating the FC stack assembly with FC converter into the FC converter assembly and FC stack assembly without first performing electrical charge discharge (forced electrical charge discharge or electrical charge self-discharge), because doing so is dangerous.
Click hereEngine / Hybrid System>FC CONTROL>FC STACK>REMOVAL
Removing and installing the FC stack assembly without first discharging the electrical charge may result in an electric shock due to the high voltage circuit.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1C8349 only is output, or DTCs except the ones in the table below are also output | A |
| Any hybrid control system DTCs in the table below are output | B |
| Any hybrid battery system DTCs in the table below are output | C |
| Any FC control system DTCs in the table below are output | D |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure |
| P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure | ||
| P060687 | Hybrid/EV Powertrain Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Powertrain Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Powertrain Control Module Processor from Monitoring Processor Missing Message | ||
| P1C9E9F | Hybrid/EV System Reset Stuck Off | ||
| P0A1B1F | Drive Motor "A" Control Module Circuit Intermittent | ||
| P1C2B00 | Drive Motor "A" Control Module A/D Processing Performance | ||
| P1CA700 | Drive Motor "A" Control Module RAM/ROM Error | ||
| P1D0400 | FC Air Compressor Motor Control Module A/D Processing Performance | ||
| P1D0500 | FC Air Compressor Motor Control Module RAM/ROM Error | ||
| P1D8F47 | FC Air Compressor Motor Control Module Watchdog/Safety MCU Failure | ||
| P1D8F49 | FC Air Compressor Motor Control Module Internal Electronic Failure | ||
| P1E3B87 | Communication Error from FC Air Compressor Motor to Drive Motor "A" Missing Message | ||
| Hybrid battery system | P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message | ||
| P060B16 | Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold | ||
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance | ||
| FC control system | P060B49 | Internal Control Module A/D Processing Performance Internal Electronic Failure | |
| P060B71 | Internal Control Module A/D Processing Performance Actuator Stuck | ||
| P060B1C | Internal Control Module A/D Processing Performance Circuit Voltage Out of Range | ||
| P060B16 | Internal Control Module A/D Processing Performance Circuit Voltage Below Threshold | ||
| Power source circuit malfunction | Hybrid control system | P06D61C | Sensor Reference Voltage "F" Circuit/Open Circuit Voltage Out of Range |
| P06E61C | Sensor Power Supply "C" Circuit/Open Circuit Voltage Out of Range | ||
| FC control system | P1F451F | FC Converter Control Module Power Relay Sense Circuit Intermittent | |
| P1F651C | FC Converter Control Module Power Supply (-5V) Circuit Voltage Out of Range | ||
| P1F661C | FC Converter Control Module Power Supply (+V5AREF) Circuit Voltage Out of Range | ||
| Communication system malfunction | Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message | ||
| FC control system | U029387 | Lost Communication with Hybrid/EV Powertrain Control Module Missing Message | |
| U116087 | Lost Communication with FCDC Control Module Missing Message | ||
| Sensor and actuator circuit malfunction | Hybrid control system | P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground | ||
| P0AE415 | Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| FC control system | P1E9011 | FC Positive Contactor Control Circuit Short to Ground | |
| P1E9015 | FC Positive Contactor Control Circuit Short to Battery or Open | ||
| P1E9211 | FC Precharge Contactor Control Circuit Short to Ground | ||
| P1E9215 | FC Precharge Contactor Control Circuit Short to Battery or Open | ||
| P1E9111 | FC Negative Contactor Control Circuit Short to Ground | ||
| P1E9115 | FC Negative Contactor Control Circuit Short to Battery or Open | ||
| Hybrid battery system | P0ABF11 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Ground | |
| P0B0E11 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Ground | ||
| P0B0E15 | Hybrid/EV Battery Current Sensor "B" Circuit Short to Auxiliary Battery or Open | ||
| P0ABF15 | Hybrid/EV Battery Current Sensor "A" Circuit Short to Auxiliary Battery or Open | ||
| P301A1C | Hybrid Battery Stack 1 Cell Voltage Detection Voltage Out of Range | ||
| P1A001C | Hybrid Battery Stack 2 Cell Voltage Detection Voltage Out of Range | ||
| P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range | ||
| P0B231C | Hybrid/EV Battery "A" Voltage Sensor Voltage Out of Range | ||
| P0ABF00 | Hybrid/EV Battery Current Sensor "A" Circuit Range/Performance | ||
| P0ABF28 | Hybrid/EV Battery Current Sensor "A" Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0ABF2A | Hybrid/EV Battery Current Sensor "A" Signal Stuck In Range | ||
| P1CBB12 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Auxiliary Battery | ||
| P1CBB14 | Hybrid/EV Battery Current Sensor Power Supply Circuit Short to Ground or Open | ||
| P0B1362 | Hybrid/EV Battery Current Sensor "A"/"B" Signal Compare Failure | ||
| FC control system | P1D1C16 | FC Converter Output Voltage Sensor Circuit Voltage Below Threshold | |
| P1D1C17 | FC Converter Output Voltage Sensor Circuit Voltage Below Threshold | ||
| P1D2017 | FC Converter Input Voltage Sensor Circuit Voltage Above Threshold | ||
| P1F009E | FC Converter Overvoltage Signal Stuck On | ||
| System malfunction | Hybrid control system | P0C7600 | Hybrid/EV Battery System Discharge Time Too Long |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | ||
| P1C8149 | High Voltage Power Resource Circuit Consumption Circuit Short | ||
| P1C8249 | High Voltage Power Resource Circuit Over Loading | ||
| P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction | ||
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge | ||
| P0D2D16 | Drive Motor "A" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold | ||
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold | ||
| P1CB69E | Drive Motor "A" Inverter Overvoltage Signal Stuck On | ||
| P0CA300 | DC/DC Converter Step Up Voltage Performance | ||
| Hybrid battery system | P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation | |
| FC control system | P1D0F62 | Cell Monitor Voltage/FC Converter Input Voltage Signal Compare Failure | |
| P1D0E62 | Inverter Output Voltage/FC Converter Output Voltage Signal Compare Failure | ||
P1C8349 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
D
Pre-procedure1
Enter the following menus: Powertrain / EV / UTILITY.
| Tester Display |
|---|
| Battery Diagnosis |
Turn the ignition switch to ON.
Procedure1
Check if the FC control System starts.
| Result | Proceed to |
|---|---|
| Not start the FC control system | A |
| Start the FC control system | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None.
Procedure1
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P1E9011, P1E9015,P1E9211 or P1E9215 is output | A |
| P1C8349 is output | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None.
Procedure1
Read the freeze frame data of DTC P1C8349.
| Tester Display | Measurement Item | Range |
|---|---|---|
| VL-Voltage before Boosting | High voltage before it is boosted | - |
| VH-Voltage after Boosting | High voltage after it is boosted | - |
| Hybrid/EV Battery Voltage | EV supply battery voltage | Min.: 0.0 V, Max.: 510.0 V |
| Hybrid/EV Battery Current | EV supply battery current | Min.: -327.68 A, Max.: 327.67 A |
| Tester Display |
|---|
| VL-Voltage before Boosting |
| VH-Voltage after Boosting |
| Hybrid/EV Battery Voltage |
| Hybrid/EV Battery Current |
| Result | Proceed to |
|---|---|
| All of the following conditions are met:
·
Difference between "Hybrid/EV Battery Voltage" and "VL-Voltage before Boosting" is 28 V or less. ·
Difference between "Hybrid/EV Battery Voltage" and "VH-Voltage after Boosting" is more than 25 V. ·
Difference between "VL-Voltage before Boosting" and "VH-Voltage after Boosting" is more than 42 V. |
A |
| In addition to the above conditions, "Hybrid/EV Battery Current" is 3 A or more. | B |
| None of the adove conditions are met. | C |
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK (for LHD) |
| OK (for RHD) |
| NG |
OK (for LHD)
OK (for RHD)
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA000
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA000
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA000
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA000
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA000
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P300449
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Check that the bolts for the FC junction cable is tightened to the specified torque, the floor under wire is connected securely, and there are no contact problems.
8 N*m (82 kgf*cm, 6 ft.*lbf)
Disconnect the FC junction cable from the inverter with converter assembly.
Procedure1
Check for arc marks on the terminals for the FC junction cable and inverter with converter assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the FC junction cable.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Check that the bolts for the FC junction cable is tightened to the specified torque, the floor under wire is connected securely, and there are no contact problems.
8 N*m (82 kgf*cm, 6 ft.*lbf)
Disconnect the FC junction cable from the FC converter assembly.
Procedure1
Check for arc marks on the terminals for the FC junction cable and FC converter assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the FC junction cable.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC junction cable from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC junction cable from the FC converter assembly.
Procedure1
| *1 | Shield Ground |
| *a | FC Junction Cable
(to Inverter With Converter Assembly) |
| *b | FC Junction Cable
(to FC Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(x2,x1)Location & Routingewd_type=routing;type=c,c;code=x2,x1 Click Connector(x2)Engine Compartment>FC Junction Cable>FC Converter Assemblyewd_type=component;type=c;code=x2;pinno=1,2 Click Connector(x1)Engine Compartment>FC Junction Cable>Inverter with Converter Assemblyewd_type=component;type=c;code=x1;pinno=1,2 |
||
| x2-1 (P) - x1-1 (P) | Ignition switch off | Below 1 Ω |
| x2-2 (N) - x1-2 (N) | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC junction cable.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Check that the bolts for the floor under wire is tightened to the specified torque, the floor under wire is connected securely, and there are no contact problems.
8 N*m (82 kgf*cm, 6 ft.*lbf)
Disconnect the floor under wire from the FC converter assembly.
Procedure1
Check for arc marks on the terminals for the floor under wire and FC converter assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the floor under wire.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 10 EV battery shield panel.
Check that the floor under wire is connected securely, and there are no contact problems.
Disconnect the floor under wire from the No. 1 EV battery junction block assembly.
Procedure1
Check for arc marks on the terminals for the floor under wire and No. 1 EV battery junction block assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the floor under wire.
Install the No. 10 EV battery shield panel.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 10 EV battery shield panel.
Disconnect the floor under wire from the No. 1 EV battery junction block assembly.
| *A | for LHD |
| *B | for RHD |
Disconnect the floor under wire from the FC converter assembly.
Procedure1
| *a | Floor Under Wire
(FC Converter Assembly Side) |
| *b | Floor Under Wire
(No. 1 EV Battery Junction Block Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(N3,N1,N2)Location & Routingewd_type=routing;type=c,c,c;code=N3,N1,N2 Click Connector(N3)Engine Compartment>Floor Under Wire>FC Converter Assemblyewd_type=component;type=c;code=N3;pinno=2,1 Click Connector(N1)Body>Floor Under Wire>No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=N1;pinno=1 Click Connector(N2)Body>Floor Under Wire>No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=N2;pinno=1 |
||
| N3-2 (CBI) - N1-1 (CBI) | Ignition switch off | Below 1 Ω |
| N3-1 (CEI) - N2-1 (CEI) | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the floor under wire.
Install the No. 10 EV battery shield panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Disconnect the floor under wire from the FC converter assembly.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC junction cable from the FC converter assembly.
Procedure1
| *a | Component without harness connected
(FC Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(N3,x2)Location & Routingewd_type=routing;type=c,c;code=N3,x2 Click Connector(N3)Engine Compartment>Floor Under Wire>FC Converter Assemblyewd_type=component;type=c;code=N3;pinno=1,2 Click Connector(x2)Engine Compartment>FC Junction Cable>FC Converter Assemblyewd_type=component;type=c;code=x2;pinno=2,1 |
||
| N3-1 (CEI) - x2-2 (N) | Ignition switch off | Below 1 Ω |
| N3-2 (CBI) - x2-1 (P) | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the FC junction cable.
Reconnect the floor under wire.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper EV battery cover panel.
Check that the EV supply battery assembly high voltage connector is connected securely, and there are no contact problems.
Disconnect the EV supply battery assembly high voltage connector from the NO. 1 EV battery junction block assembly.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Procedure1
Check for arc marks on the terminals for the EV supply battery assembly high voltage connector and NO. 1 EV battery junction block assembly.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the EV supply battery assembly high voltage connector.
Install the upper EV battery cover panel.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper EV battery cover panel.
Check that the EV supply battery assembly high voltage connector is connected securely, and there are no contact problems.
Disconnect the EV supply battery assembly high voltage connector from the EV battery terminal block.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Procedure1
Check for arc marks on the terminals for the EV supply battery assembly high voltage connector and EV battery terminal block.
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Post-procedure1
Reconnect the EV supply battery assembly high voltage connector.
Install the upper EV battery cover panel.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper EV battery cover panel.
Disconnect the EV supply battery assembly high voltage connector from the EV battery terminal block.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Procedure1
| *a | Component without harness connected
(to EV Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z18,z19)Location & Routingewd_type=routing;type=c,c;code=z18,z19 Click Connector(z18)Body>other>EV Supply Battery Assembly , EV Battery Terminal Blockewd_type=component;type=c;code=z18;pinno=1 Click Connector(z19)Body>other>EV Supply Battery Assembly , EV Battery Terminal Blockewd_type=component;type=c;code=z19;pinno=1 |
||
| z18-1 (+) - z19-1 (-) | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the EV supply battery assembly high voltage connector.
Install the upper EV battery cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper EV battery cover panel.
Disconnect the EV supply battery assembly high voltage connector from the EV battery terminal block.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Procedure1
| *a | No. 1 EV Supply Stack Sub-assembly
(EV Battery Terminal Block Side) |
| *b | No. 1 EV Supply Stack Sub-assembly
(Service Plug Grip Side) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z18)Location & Routingewd_type=routing;type=c;code=z18 Click Connector(z18)Body>other>EV Supply Battery Assembly , EV Battery Terminal Blockewd_type=component;type=c;code=z18;pinno=1 |
||
| z18-1 (+) - 1 | Ignition switch off | 50 V or higher |
Do not allow the probes of the electrical tester to contact each other during this inspection.
Disconnect the EV supply battery assembly high voltage connector from the No. 1 EV battery junction block assembly.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
| *a | No. 1 EV Supply Stack Sub-assembly
(Service Plug Grip Side) |
| *b | No. 1 EV Supply Stack Sub-assembly
(No. 1 EV Battery Junction Block Assembly Side) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z12)Location & Routingewd_type=routing;type=c;code=z12 Click Connector(z12)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z12;pinno=1 |
||
| 2 - z12-1 (-) | Ignition switch off | Below 1 Ω |
Do not allow the probes of the electrical tester to contact each other during this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the two EV supply battery assembly high voltage connectors.
Install the upper EV battery cover panel.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper EV battery cover panel.
Disconnect the EV supply battery assembly high voltage connector from the No. 1 EV battery junction block assembly.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Disconnect the EV supply battery assembly high voltage connector.
Insulate each disconnected high-voltage connector with insulating tape. Wrap the connector from the wire harness side to the end of the connector.
Procedure1
| *a | No. 2 EV Supply Stack Sub-assembly
(No. 1 EV Battery Junction Block Assembly Side) |
| *b | No. 2 EV Supply Stack Sub-assembly
(EV Battery Terminal Block Side) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z13,z19)Location & Routingewd_type=routing;type=c,c;code=z13,z19 Click Connector(z13)Body>other>EV Supply Battery Assembly , No. 1 EV Battery Junction Block Assemblyewd_type=component;type=c;code=z13;pinno=1 Click Connector(z19)Body>other>EV Supply Battery Assembly , EV Battery Terminal Blockewd_type=component;type=c;code=z19;pinno=1 |
||
| z13-1 (+) - z19-1 (-) | Ignition switch off | 50 V or higher |
Do not allow the probes of the electrical tester to contact each other during this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the 2 EV supply battery assembly high voltage connectors.
Install the upper EV battery cover panel.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P06881F
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
Turn the ignition switch to ON (READY).
Procedure1
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| P300449 is output | B |
| P1C8349 is output | C |
Because P300449 uses 2-trip detection logic, the DTC detection conditions need to be met 2 times.
Post-procedure1
Turn the ignition switch off.
A
B
C
Check the operating sound from the relay when the Active Test is performed.
| Tester Display |
|---|
| Activate the FC Negative Relay |
| Tester Display |
|---|
| Activate the FC Positive Relay |
There is an operating sound without hunting or a delayed response
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
| *A | for LHD |
| *B | for RHD |
Remove the connector cover assembly from the inverter with converter assembly.
| *A | for LHD |
| *B | for RHD |
Disconnect the front compartment main wire from the inverter with converter assembly.
Make sure that no foreign matter has entered or contaminated the front compartment main wire.
| *A | for LHD |
| *B | for RHD |
Disconnect the FC junction cable from the inverter with converter assembly.
Make sure that no foreign matter has entered or contaminated the FC junction cable.
Procedure1
| *A | for LHD |
| *B | for RHD |
Measure the resistance according to the value(s) in the table below.
Do not use a megohmmeter.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (-) (Negative (-) probe) - 1 (+) (Positive (+) probe) | Ignition switch off | 10 kΩ or higher |
Be sure to inspect with connecting thetester probes to the tips of the terminal.
Perform an inspection with the FC junction cable and front compartment main wire removed from the inverter with converter assembly.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Replace the FC converter assembly components listed below.
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>DISASSEMBLY
FC stack main relay (FRB)
FC stack main relay (FRG)
FC precharge junction assembly (FRP)
No. 1 FC converter wire
No. 2 FC converter wire
FC converter power module transistor
FCDC converter control ECU board sub-assembly
Refer to the parts location for the FC converter assembly components.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PARTS LOCATION
Refer to the system description for the parts location of the FC converter assembly components.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>SYSTEM DESCRIPTION
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1D0619
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the electric heater sub-assembly.
Disconnect the B19 FC converter assembly.
Disconnect the A16 EV control ECU.
Procedure1
| *a | Front view of wire harness connector
(to FC Converter Assembly) |
| *b | Rear view of wire harness connector
(to EV Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A16,B19)Location & Routingewd_type=routing;type=c,c;code=A16,B19 Click Connector(A16)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A16;pinno=3,5,6 Click Connector(B19)Engine Compartment>No. 2 Stack Wire>FC Converter Assemblyewd_type=component;type=c;code=B19;pinno=8,2,3 |
||
| A16-3 (FRB+) - B19-8 (FRB+) | Ignition switch off | Below 1 Ω |
| A16-5 (FRB-) - B19-2 (FRB-) | Ignition switch off | Below 1 Ω |
| A16-6 (FRP) - B19-3 (FRP) | Ignition switch off | Below 1 Ω |
| A16-3 (FRB+) or B19-8 (FRB+) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A16-5 (FRB-) or B19-2 (FRB-) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| A16-6 (FRP) or B19-3 (FRP) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A16 EV control ECU.
Reconnect the B19 FC converter assembly.
Install the electric heater sub-assembly.
OK
NG
Pre-procedure1
Disconnect the A16 EV control ECU.
Procedure1
| *a | Rear view of wire harness connector
(to EV Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A16)Location & Routingewd_type=routing;type=c;code=A16 Click Connector(A16)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A16;pinno=3,5,6 |
||
| A16-3 (FRB+) - A16-5 (FRB-) | Ignition switch off | 11.07 to 13.53 Ω |
| A16-6 (FRP) - Body ground | Ignition switch off | 112 to 274 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A16 EV control ECU.
OK
NG
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Replace the FC converter assembly components listed below.
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>DISASSEMBLY
FC stack main relay (FRB)
FC precharge junction assembly (FRP)
No. 1 FC converter wire
No. 2 FC converter wire
FCDC converter control ECU board sub-assembly
Refer to the parts location for the FC converter assembly components.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PARTS LOCATION
Refer to the system description for the parts location of the FC converter assembly components.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>SYSTEM DESCRIPTION