Refer to high voltage system diagram for the System Description.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>SYSTEM DESCRIPTION
The FC converter assembly increases the FC stack voltage up to approximately DC650 V. Then the inverter converts the high-voltage direct current of the FC converter into alternating current and drives the motor.
The FC boost control ECU detects high voltage before boosting (FVL) and high voltage after boosting (FVH) using the voltage sensor, which is located inside the FC converter assembly. The FC boost control ECU controls the operation of the FC converter assembly based on the voltage before and after boosting, and controls the FC stack current and voltage to become the target values.
If an overvoltage occurs in the motor inverter or FC air compressor motor inverter, the FC boost control ECU detects a malfunction.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1F0117 | FC Converter Output Voltage Circuit Voltage Above Threshold | The FC converter output voltage (FVH) is detected to be too high. (Overvoltage)
(1 trip detection logic) |
·
FCV transaxle with motor assembly ·
FC air compressor with motor assembly ·
FC converter assembly ·
Inverter with converter assembly ·
EV battery junction block assembly ·
No. 1 frame wire ·
Service plug grip (for EV) (EV battery fuse) ·
EV control ECU ·
Wire harness or connector |
Master Warning: Comes on | FCDC | B |
| DTC No. | Data List |
|---|---|
| P1F0117 | FC Converter Output Voltage |
Refer to the wiring diagram for the motor resolver circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor Resolver Circuit
Refer to the wiring diagram for the FC air compressor resolver circuit.
Refer to the wiring diagram for the high-voltage circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA649
Refer to the wiring diagram for the inverter low-voltage circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Inverter Low-voltage Circuit
Refer to the wiring diagram for the FC boost converter low-voltage circuit.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>ECU Power Source Circuit
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side.
Make sure to remove the EV supply battery assembly service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (w/ 1500W Type Voltage Inverter)
After removing the service plug grip from the EV supply battery assembly, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system. After removing the FC converter power outlet cable (inverter with converter assembly) on FC converter side and use the "HIGH-VOLTAGE, DO NOT TOUCH" sign to notify other technicians that you are working on the high-voltage system.
After removal of the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, wait for at least 10 minutes before touching the high-voltage connectors and terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
At least 10 minutes are necessary to discharge the high-voltage capacitors inside the inverter with converter assembly and FC stack assembly.
Since high voltage accumulates within the FC stack assembly with FC converter, never perform the work of separating the FC stack assembly with FC converter into the FC converter assembly and FC stack assembly without first performing electrical charge discharge (forced electrical charge discharge or electrical charge self-discharge), because doing so is dangerous.
Click hereEngine / Hybrid System>FC CONTROL>FC STACK>REMOVAL
Removing and installing the FC stack assembly without first discharging the electrical charge may result in an electric shock due to the high voltage circuit.
When reinstalling the service plug grip to the EV supply battery assembly, after lowering the EV supply battery assembly service plug grip 90°, securely slide it until a "click" sound is heard.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>PRECAUTION
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Drive the vehicle in a city area under the vehicle and driving conditions based on the recorded freeze frame data for approximately 10 minutes.
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P1F0117 is output | A |
| P1F0117 and DTCs other than the DTCs in the table below are output | B |
| P1F0117 and any DTCs in the table below are output | C |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Microcomputer malfunction | P060B16 | Internal Control Module A/D Processing Performance Circuit Voltage Below Threshold |
| P060B1C | Internal Control Module A/D Processing Performance Circuit Voltage Out of Range | |
| P060B49 | Internal Control Module A/D Processing Performance Internal Electronic Failure | |
| P060B71 | Internal Control Module A/D Processing Performance Actuator Stuck | |
| P1F451F | FC Converter Control Module Power Relay Sense Circuit Intermittent | |
| Power source circuit malfunction | P1F661C | FC Converter Control Module Power Supply (+V5AREF) Circuit Voltage Out of Range |
| Sensor and actuator circuit malfunction | P1D1C16 | FC Converter Output Voltage Sensor Circuit Voltage Below Threshold |
| P1D1C17 | FC Converter Output Voltage Sensor Circuit Voltage Above Threshold | |
| P1D2017 | FC Converter Input Voltage Sensor Circuit Voltage Above Threshold | |
| P1D3011 | Phase U Reactor Current Sensor Circuit Short to Ground | |
| P1D3015 | Phase U Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D301C | Phase U Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3028 | Phase U Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D3511 | Phase V Reactor Current Sensor Circuit Short to Ground | |
| P1D3515 | Phase V Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D351C | Phase V Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3528 | Phase V Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D3A11 | Phase W Reactor Current Sensor Circuit Short to Ground | |
| P1D3A15 | Phase W Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D3A1C | Phase W Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3A28 | Phase W Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D4011 | Phase X Reactor Current Sensor Circuit Short to Ground | |
| P1D4015 | Phase X Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D401C | Phase X Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D4028 | Phase X Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D4A14 | Phase V Temperature Sensor Circuit Short to Ground or Open | |
| P1D4F62 | Total Reactor Current/FC Current Signal Compare Failure | |
| P1D0618 | FC Converter Phase U Current Circuit Current Below Threshold | |
| P1D0718 | FC Converter Phase V Current Circuit Current Below Threshold | |
| P1D0818 | FC Converter Phase W Current Circuit Current Below Threshold | |
| P1D0918 | FC Converter Phase X Current Circuit Current Below Threshold | |
| System malfunction | P1D0619 | FC Converter Phase U Current Circuit Current Above Threshold |
| P1D0719 | FC Converter Phase V Current Circuit Current Above Threshold | |
| P1D0819 | FC Converter Phase W Current Circuit Current Above Threshold | |
| P1D0919 | FC Converter Phase X Current Circuit Current Above Threshold | |
| P1DDA4B | FC Converter Phase U Over Temperature | |
| P1DDB4B | FC Converter Phase V Over Temperature | |
| P1DDC4B | FC Converter Phase W Over Temperature | |
| P1DDD4B | FC Converter Phase X Over Temperature | |
| P1D0E62 | Inverter Output Voltage/FC Converter Output Voltage Signal Compare Failure | |
| P1D0F62 | Cell Monitor Voltage/FC Converter Input Voltage Signal Compare Failure | |
| P1DDA9E | FC Converter Phase U Fail Signal Stuck On | |
| P1DDB9E | FC Converter Phase V Fail Signal Stuck On | |
| P1DDC9E | FC Converter Phase W Fail Signal Stuck On | |
| P1DDD9E | FC Converter Phase X Fail Signal Stuck On | |
| P1DDA00 | FC Converter Phase U Performance | |
| P1DDB00 | FC Converter Phase V Performance | |
| P1DDC00 | FC Converter Phase W Performance | |
| P1DDD00 | FC Converter Phase X Performance | |
DTC P1F0117 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| No DTCs in the table below are output | A |
| Any of the DTCs in the table below are output | B |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Microcomputer malfunction | P0A1B00 | Drive Motor "A" Control Module Performance |
| P0A1B04 | Drive Motor "A" Control Module System Internal Failure | |
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | |
| P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | |
| P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | |
| P1CB300 | Drive Motor "A" Position Sensor REF Signal Oscillation Stop | |
| P1E8649 | FC Air Compressor Motor Position Sensor Internal Electronic Failure | |
| P1E8800 | FC Air Compressor Motor Position Sensor REF Signal Oscillation Stop | |
| P1E8738 | FC Air Compressor Motor Position Sensor REF Signal Frequency Incorrect | |
| Sensor and actuator circuit malfunction | P1C8349 | High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction |
| P1E9011 | FC Positive Contactor Control Circuit Short to Ground | |
| P1E9015 | FC Positive Contactor Control Circuit Short to Battery or Open | |
| P1E9111 | FC Negative Contactor Control Circuit Short to Ground | |
| P1E9115 | FC Negative Contactor Control Circuit Short to Battery or Open | |
| P1E9211 | FC Precharge Contactor Control Circuit Short to Ground | |
| P1E9215 | FC Precharge Contactor Control Circuit Short to Battery or Open | |
| P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold | |
| P0A3F1C | Drive Motor "A" Position Sensor Circuit Voltage Out of Range | |
| P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum | |
| P1D7516 | FC Air Compressor Motor Position Sensor Circuit Voltage Below Threshold | |
| P1D751C | FC Air Compressor Motor Position Sensor Circuit Voltage Out of Range | |
| P1D7522 | FC Air Compressor Motor Position Sensor Signal Amplitude > Maximum | |
| P0BE91C | Drive Motor "A" Phase V Current Sensor "A" Circuit Voltage Out of Range | |
| P1C3C62 | Drive Motor "A" Phase V Current Sensor "A"/"B" Signal Compare Failure | |
| P1C491C | Drive Motor "A" Phase V Current Sensor "B" Circuit Voltage Out of Range | |
| P1C6D28 | Drive Motor "A" Phase V Current Sensor "A"/"B" Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P0BED1C | Drive Motor "A" Phase W Current Sensor "A" Circuit Voltage Out of Range | |
| P1C3D62 | Drive Motor "A" Phase W Current Sensor "A"/"B" Signal Compare Failure | |
| P1C4E1C | Drive Motor "A" Phase W Current Sensor "B" Circuit Voltage Out of Range | |
| P1C6E28 | Drive Motor "A" Phase W Current Sensor "A"/"B" Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1E9362 | FC Air Compressor Motor Phase V Current Sensor "A"/"B" Signal Compare Failure | |
| P1F0E1C | FC Air Compressor Motor Phase V Current Sensor "A" Circuit Voltage Out of Range | |
| P1F101C | FC Air Compressor Motor Phase V Current Sensor "B" Circuit Voltage Out of Range | |
| P1F1228 | FC Air Compressor Motor Phase V Current Sensor "A"/"B" Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1E9462 | FC Air Compressor Motor Phase W Current Sensor "A"/"B" Signal Compare Failure | |
| P1F0F1C | FC Air Compressor Motor Phase W Current Sensor "A" Circuit Voltage Out of Range | |
| P1F111C | FC Air Compressor Motor Phase W Current Sensor "B" Circuit Voltage Out of Range | |
| P1F1328 | FC Air Compressor Motor Phase W Current Sensor "A"/"B" Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P0A9300 | Inverter "A" Cooling System Performance | |
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure | |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal | |
| System malfunction | P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | |
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | |
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | |
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON | |
| P1AC300 | Drive Motor "A" Inverter Circuit Short (System Performance) | |
| P1B2900 | Drive Motor "A" Inverter Overcurrent (System Performance) | |
| P0D2D16 | Drive Motor "A" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold | |
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold | |
| P1A8E00 | Drive Motor "A" Inverter Overvoltage (Inverter Performance) | |
| P0A784B | Drive Motor "A" Inverter Over Temperature | |
| P0A789E | Drive Motor "A" Inverter Fail Signal Stuck On | |
| P1ABF00 | Drive Motor "A" Inverter Circuit Short (Inverter Performance) | |
| P0C1900 | Drive Motor "A" Torque Delivered Performance | |
| P1A8400 | Drive Motor "A" Inverter Overvoltage (Control Module Performance) | |
| P1A8900 | Drive Motor "A" Inverter Overvoltage (Position Sensor Circuit Range/Performance) | |
| P1AB400 | Drive Motor "A" Inverter Circuit Short (Control Module Performance) | |
| P1AB900 | Drive Motor "A" Inverter Circuit Short (Position Sensor Circuit Range/Performance) | |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | |
| P1AE400 | Drive Motor "A" Inverter Overcurrent (Control Module Performance) | |
| P1B1400 | Drive Motor "A" Inverter Overcurrent (Inverter Performance) | |
| P1AF900 | Drive Motor "A" Inverter Overcurrent (Position Sensor Circuit Range/Performance) | |
| P334F00 | FC Air Compressor Inverter Overcurrent (Control Module Performance) | |
| P337F00 | FC Air Compressor Inverter Overcurrent (Inverter Performance) | |
| P336F00 | FC Air Compressor Inverter Overcurrent (Position Sensor Circuit Range/Performance) | |
| P338F00 | FC Air Compressor Inverter Overcurrent (System Performance) | |
| P1E8E00 | FC Air Compressor Motor Torque Delivered Performance | |
| P1D824B | FC Air Compressor Inverter Over Temperature | |
| P1EF800 | FC Air Compressor Inverter Circuit Short (Control Module Performance) | |
| P1EFB00 | FC Air Compressor Inverter Circuit Short (Inverter Performance) | |
| P1EF900 | FC Air Compressor Inverter Circuit Short (Position Sensor Circuit Range/Performance) | |
| P1D829E | FC Air Compressor Inverter Fail Signal Stuck On | |
| P1EFA00 | FC Air Compressor Inverter Circuit Short (System Performance) | |
| P0BFF1D | Drive Motor "A" Current Circuit Current Out of Range | |
| P1F141D | FC Air Compressor Motor Circuit Current Out of Range | |
| P1AA900 | DC/DC Converter "A" Overcurrent (System Performance) | |
| P0CA300 | DC/DC Converter Step Up Voltage Performance | |
| P1A0F00 | DC/DC Converter "A" Overvoltage (Control Module Performance) | |
| P1A6F00 | DC/DC Converter "A" Overvoltage (Inverter Performance) | |
| P1A2F00 | DC/DC Converter "A" Overvoltage (Position Sensor Circuit Range/Performance) | |
| P0A944B | DC/DC Converter "A" Over Temperature | |
| P1A9400 | DC/DC Converter "A" Overcurrent (Control Module Performance) | |
| P1AA400 | DC/DC Converter "A" Overcurrent (Inverter Performance) | |
| P1A9900 | DC/DC Converter "A" Overcurrent (Position Sensor Circuit Range/Performance) | |
| P0A949E | DC/DC Converter "A" Fail Signal Stuck On | |
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range | |
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure | |
| P0E3116 | DC/DC Converter Voltage Sensor "A" Circuit Voltage Below Threshold | |
| P0E3117 | DC/DC Converter Voltage Sensor "A" Circuit Voltage Above Threshold | |
| P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | |
| P33B99F | Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off | |
DTC P1F0117 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1D0619
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
A
B
C
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor Resolver Circuit
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor High-voltage Circuit
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Inverter Low-voltage Circuit
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1D0619
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
A
B
C
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1D0E62
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems | There are no arc marks | A |
| The terminals are not connected securely and there is a contact problem | There are arc marks | B |
| The terminals are connected securely and there are no contact problems | There are arc marks | |
| The terminals are not connected securely and there is a contact problem | There are no arc marks | C |
A
B
C
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Pre-procedure1
Turn the ignition switch to ON (READY).
Drive the vehicle in a city area under the vehicle and driving conditions based on the recorded freeze frame data for approximately 10 minutes.
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1F0117 is output | A |
| DTCs are not output | B |
Post-procedure1
Turn the ignition switch off.
A
B