The MG ECU, which is built into the inverter with converter assembly, monitors its internal operation and detects the following malfunctions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1E8649 | FC Air Compressor Motor Position Sensor Internal Electronic Failure | FC air compressor motor resolver angle error
The difference between the resolver angle for control and estimated resolver angle exceeds the allowable limit. (1 trip detection logic) |
·
Inverter with converter assembly ·
FC air compressor motor assembly ·
FCV with motor transaxle assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV | A |
| P1E8738 | FC Air Compressor Motor Position Sensor REF Signal Frequency Incorrect | FC air compressor motor resolver REF signal cycle error
Excitation signal (REF signal) for resolver angle detection cycle error (1 trip detection logic) |
·
Inverter with converter assembly ·
FC air compressor with motor assembly ·
FCV with motor transaxle assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV | A |
| P1E8800 | FC Air Compressor Motor Position Sensor REF Signal Oscillation Stop | FC air compressor motor resolver REF signal oscillation stop error
An error is detected when the excitation signal (REF signal) for resolver angle detection is not detected. (1 trip detection logic) |
·
Inverter with converter assembly ·
FC air compressor with motor assembly ·
FCV with motor transaxle assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV | A |
| DTC No. | Data List |
|---|---|
| P1E8649 | FC Air Compressor Motor Speed |
| P1E8738 | |
| P1E8800 |
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Turn the ignition switch to ON and wait for 5 seconds or more.*
Enter the following menus: Powertrain / EV / Data List / FC Work Mode, FC IntermittentOperation.
Push the P position switch (shift position indicator) to select park (P), turn the ignition switch to ON (READY) and wait until the FCsystem is started. Waiting for at least 2 minutes is required after turning the ignition switch to ON (READY).
- FC system is started: "Working" is displayed for the Data List item "FC Work Mode" and "FC Intermittent Operation" is OFF.
With the FC system operating, wait for 15 seconds or more.
Drive the vehicle in drive (D) for 5 m (16 ft.) or more.
Drive the vehicle in reverse (R) for 5 m (16 ft.) or more.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
*: Lightly wiggle the connectors and wire harnesses up and down and right and left.
If excessive pressure is applied while the connectors and wire harnesses are wiggled, they may be damaged. After the inspection, make sure to return the wire harnesses and clamps to their original position.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removal of the service plug grips of both FC stack assembly and EV battery, wait for at least 10 minutes before touching the high-voltage connectors and terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
At least 10 minutes are necessary to discharge the high-voltage capacitors inside the inverter with converter assembly and FC stack assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P1E8649, P1E8738 or P1E8800 only is output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| Relevant DTC | |
|---|---|
| P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P1D7516 | FC Air Compressor Motor Position Sensor Circuit Voltage Below Threshold |
| P1D751C | FC Air Compressor Motor Position Sensor Circuit Voltage Out of Range |
| P1D7522 | FC Air Compressor Motor Position Sensor Signal Amplitude > Maximum |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A001C
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-20 (GRF) - Body ground | Ignition switch ON | Below 1 V |
| A19-9 (GRFG) - Body ground | Ignition switch ON | Below 1 V |
| A19-18 (GSN) - Body ground | Ignition switch ON | Below 1 V |
| A19-7 (GSNG) - Body ground | Ignition switch ON | Below 1 V |
| A19-17 (GCS) - Body ground | Ignition switch ON | Below 1 V |
| A19-6 (GCSG) - Body ground | Ignition switch ON | Below 1 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-20 (GRF) - Body ground | Ignition switch ON | Below 1 V |
| A18-9 (GRFG) - Body ground | Ignition switch ON | Below 1 V |
| A18-18 (GSN) - Body ground | Ignition switch ON | Below 1 V |
| A18-7 (GSNG) - Body ground | Ignition switch ON | Below 1 V |
| A18-17 (GCS) - Body ground | Ignition switch ON | Below 1 V |
| A18-6 (GCSG) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-20 (GRF) - A19-9 (GRFG) | Ignition switch off | 6.5 to 21.5 Ω |
| A19-18 (GSN) - A19-7 (GSNG) | Ignition switch off | 10.0 to 37.5 Ω |
| A19-17 (GCS) - A19-6 (GCSG) | Ignition switch off | 9.0 to 35.5 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-20 (GRF) - A18-9 (GRFG) | Ignition switch off | 6.5 to 21.5 Ω |
| A18-18 (GSN) - A18-7 (GSNG) | Ignition switch off | 10.0 to 37.5 Ω |
| A18-17 (GCS) - A18-6 (GCSG) | Ignition switch off | 9.0 to 35.5 Ω |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68°F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C (°F).)
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-20 (GRF) or A19-9 (GRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-18 (GSN) or A19-7 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-17 (GCS) or A19-6 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-20 (GRF) or A18-9 (GRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-18 (GSN) or A18-7 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-17 (GCS) or A18-6 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-40 (MRF) - Body ground | Ignition switch ON | Below 1 V |
| A19-29 (MRFG) - Body ground | Ignition switch ON | Below 1 V |
| A19-39 (MSN) - Body ground | Ignition switch ON | Below 1 V |
| A19-28 (MSNG) - Body ground | Ignition switch ON | Below 1 V |
| A19-38 (MCS) - Body ground | Ignition switch ON | Below 1 V |
| A19-27 (MCSG) - Body ground | Ignition switch ON | Below 1 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-40 (MRF) - Body ground | Ignition switch ON | Below 1 V |
| A18-29 (MRFG) - Body ground | Ignition switch ON | Below 1 V |
| A18-39 (MSN) - Body ground | Ignition switch ON | Below 1 V |
| A18-28 (MSNG) - Body ground | Ignition switch ON | Below 1 V |
| A18-38 (MCS) - Body ground | Ignition switch ON | Below 1 V |
| A18-27 (MCSG) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Procedure1
| *A | for LHD |
| *B | for RHD |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-40 (MRF) - A19-29 (MRFG) | Ignition switch off | 8.8 to 14.8 Ω |
| A19-39 (MSN) - A19-28 (MSNG) | Ignition switch off | 16.1 to 28.1 Ω |
| A19-38 (MCS) - A19-27 (MCSG) | Ignition switch off | 18.0 to 30.1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-40 (MRF) - A18-29 (MRFG) | Ignition switch off | 8.8 to 14.8 Ω |
| A18-39 (MSN) - A18-28 (MSNG) | Ignition switch off | 16.1 to 28.1 Ω |
| A18-38 (MCS) - A18-27 (MCSG) | Ignition switch off | 18.0 to 30.1 Ω |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68°F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C (°F).)
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19)Location & Routingewd_type=routing;type=c;code=A19 |
||
| A19-40 (MRF) or A19-29 (MRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-39 (MSN) or A19-28 (MSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-38 (MCS) or A19-27 (MCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18)Location & Routingewd_type=routing;type=c;code=A18 |
||
| A18-40 (MRF) or A18-29 (MRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-39 (MSN) or A18-28 (MSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-38 (MCS) or A18-27 (MCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P1E8649
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Check the connection condition of the motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Check the connection condition of the FC air compressor motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A2A11
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Check the connection condition of the motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Disconnect the G154 motor resolver connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *a | Front view of wire harness connector
(to Motor Resolver) |
*b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19,G154)Location & Routingewd_type=routing;type=c,c;code=A19,G154 Click Connector(G154)Body>Floor Wire / No. 3 Floor Wire>FCV Transaxle with Motor Assemblyewd_type=component;type=c;code=G154;pinno=6,1,10,13,8,11 |
||
| A19-40(MRF) - G154-6(MRF) | Ignition switch off | below 1 Ω |
| A19-29(MRFG) - G154-1(MRFG) | Ignition switch off | below 1 Ω |
| A19-39(MSN) - G154-10(MSN) | Ignition switch off | below 1 Ω |
| A19-28(MSNG) - G154-13(MSNG) | Ignition switch off | below 1 Ω |
| A19-38(MCS) - G154-8(MCS) | Ignition switch off | below 1 Ω |
| A19-27(MCSG) - G154-11(MCSG) | Ignition switch off | below 1 Ω |
| A19-40 (MRF) or G154-6 (MRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-29 (MRFG) or G154-1 (MRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-39 (MSN) or G154-10 (MSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-28 (MSNG) or G154-13 (MSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-38 (MCS) or G154-8 (MCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-27 (MCSG) or G154-11 (MCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A18,G154)Location & Routingewd_type=routing;type=c,c;code=A18,G154 Click Connector(G154)Body>Floor Wire / No. 3 Floor Wire>FCV Transaxle with Motor Assemblyewd_type=component;type=c;code=G154;pinno=6,1,10,13,8,11 |
||
| A18-40(MRF) - G154-6(MRF) | Ignition switch off | below 1 Ω |
| A18-29(MRFG) - G154-1(MRFG) | Ignition switch off | below 1 Ω |
| A18-39(MSN) - G154-10(MSN) | Ignition switch off | below 1 Ω |
| A18-28(MSNG) - G154-13(MSNG) | Ignition switch off | below 1 Ω |
| A18-38(MCS) - G154-8(MCS) | Ignition switch off | below 1 Ω |
| A18-27(MCSG) - G154-11(MCSG) | Ignition switch off | below 1 Ω |
| A18-40 (MRF) or G154-6 (MRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-29 (MRFG) or G154-1 (MRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-39 (MSN) or G154-10 (MSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-28 (MSNG) or G154-13 (MSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-38 (MCS) or G154-8 (MCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A18-27 (MCSG) or G154-11 (MCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
The drive motor resolver is not available as a supply part. If it requires replacement, replace the FCV with motor transaxle assembly.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the G154 motor resolver connector.
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG
Check the connection condition of the stack wire connnector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Check the connection condition of the FC air compressor motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
Disconnect the B24 FC air compressor motor resolver connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *A | for LHD | *B | for RHD |
| *a | Front view of wire harness connector
(to FC Air Compressor Motor Resolver) |
*b | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19,B24)Location & Routingewd_type=routing;type=c,c;code=A19,B24 Click Connector(B24)Engine Compartment>No. 2 Stack Wire>FC Air Compressor with Motor Assemblyewd_type=component;type=c;code=B24;pinno=1,5,2,6,3,7 |
||
| A19-20(GRF) - B24-1(GRF) | Ignition switch off | below 1 Ω |
| A19-9(GRFG) - B24-5(GRFG) | Ignition switch off | below 1 Ω |
| A19-18(GSN) - B24-2(GSN) | Ignition switch off | below 1 Ω |
| A19-7(GSNG) - B24-6(GSNG) | Ignition switch off | below 1 Ω |
| A19-17(GCS) - B24-3(GCS) | Ignition switch off | below 1 Ω |
| A19-6(GCSG) - B24-7(GCSG) | Ignition switch off | below 1 Ω |
| A19-20 (GRF) or B24-1 (GRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-9 (GRFG) or B24-5 (GRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-18 (GSN) or B24-2 (GSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-7 (GSNG) or B24-6 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-17 (GCS) or B24-3 (GCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-6 (GCSG) or B24-7 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A19,B24)Location & Routingewd_type=routing;type=c,c;code=A19,B24 Click Connector(B24)Engine Compartment>No. 2 Stack Wire>FC Air Compressor with Motor Assemblyewd_type=component;type=c;code=B24;pinno=1,5,2,6,3,7 |
||
| A19-20 (GRF) - B24-1 (GRF) | Ignition switch off | below 1 Ω |
| A19-9 (GRFG) - B24-5 (GRFG) | Ignition switch off | below 1 Ω |
| A19-18 (GSN) - B24-2 (GSN) | Ignition switch off | below 1 Ω |
| A19-7 (GSNG) - B24-6 (GSNG) | Ignition switch off | below 1 Ω |
| A19-17 (GCS) - B24-3 (GCS) | Ignition switch off | below 1 Ω |
| A19-6 (GCSG) - B24-7 (GCSG) | Ignition switch off | below 1 Ω |
| A19-20 (GRF) or B24-1 (GRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-9 (GRFG) or B24-5 (GRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-18 (GSN) or B24-2 (GSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-7 (GSNG) or B24-6 (GSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-17 (GCS) or B24-3 (GCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| A19-6 (GCSG) or B24-7 (GCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the B24 FC air compressor motor resolver connector.
Reconnect the A19*1 or A18*2 inverter with converter assembly connector.
*1: for LHD
*2: for RHD
OK
NG