MALFUNCTION DESCRIPTION
This DTC indicates that a large current flowed through the rear motor inverter. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description |
|---|---|
| Rear traction motor assembly | ·
Open or short circuit in the motor coils ·
Motor (MGR) internal malfunction (iron particles or damage from foreign objects) |
| Resolver | Open or short circuit in the rear motor resolver |
| Inverter | ·
Rear hybrid motor control inverter assembly internal circuit malfunction ·
Malfunction in ECU that controls the rear hybrid motor control inverter assembly ·
Rear hybrid motor control inverter assembly control sensor (current sensor, VLR sensor) |
| Inverter cooling system | HV inverter cooling fan malfunction |
For a description of the inverter.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>P0DA316
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P0A799E | Drive Motor "B" Inverter Stuck On | Rear motor inverter fail signal detected (circuit malfunction)
(1 trip detection logic) |
·
Wire harness or connector ·
HV inverter cooling fan ·
Floor wire ·
Rear traction motor cable ·
Rear traction motor assembly ·
PCU-RR fuse ·
Rear hybrid motor control inverter assembly ·
PCU RR relay |
Does not come on | Master Warning:
Comes on |
Rear Motor Generator | A |
| P1C5E19 | Drive Motor "B" Inverter Circuit Current Above Threshold | Rear motor inverter fail signal detected:
A malfunction is detected in any of the rear motor components (rear motor inverter, rear motor, rear motor control ECU, etc.) (1 trip detection logic) |
·
Wire harness or connector ·
HV inverter cooling fan ·
Floor wire ·
Rear traction motor cable ·
Rear traction motor assembly ·
PCU-RR fuse ·
Rear hybrid motor control inverter assembly ·
PCU RR relay |
Does not come on | Master Warning:
Comes on |
Rear Motor Generator | A |
| DTC No. | Data List |
|---|---|
| P0A799E
P1C5E19 |
·
Rear Motor Inverter Temperature ·
Emergency Shutdown Signal ·
Rear Inverter Shut Down Status |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON and wait for 5 seconds or more.
Turn the ignition switch to ON (READY) and wait for 5 seconds or more.
With the vehicle stopped, begin moving with the accelerator opening angle between 20% to 50% and a speed of approximately 10 km/h (6 mph), then stop the vehicle and repeat the same procedure several times.
While doing this, check that the "Rear motor torque" value does not remain at 0 N*m continuously, but rather changes to indicate that the rear motor is operating.
Unless rear motor torque is restricted due to DTC output, the rear motor torque will not remain at 0 N*m continuously.
Enter the following menus: Powertrain / Rear Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
Refer to the wiring diagram for the Rear Motor Resolver Circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Motor Resolver Circuit
Refer to the wiring diagram for the Rear Motor High-voltage Circuit.
Refer to the wiring diagram for the Rear Inverter Low-voltage Circuit.
Refer to the wiring diagram for the Rear Cooling System Circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Cooling System
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0A799E or P1C5E19 for Rear motor generator control system is output | A |
| P0A799E or P1C5E19 is output and DTCs other than the DTCs in the table below are output | B |
| P0A799E or P1C5E19 is output and Insulation malfunction of Hybrid control system DTCs in the table below are output | C |
| P0A799E or P1C5E19 is output and High voltage circuit malfunction of Hybrid control system DTCs in the table below are output | D |
| P0A799E or P1C5E19 is output and Microcomputer malfunction of Motor generator control system DTCs in the table below are output | E |
| P0A799E or P1C5E19 is output and Microcomputer malfunction of Rear motor generator control system DTCs in the table below are output | F |
| P0A799E or P1C5E19 is output and Power source circuit malfunction of Rear motor generator control system DTCs in the table below are output | G |
| P0A799E or P1C5E19 is output and Communication malfunction of Motor generator control system DTCs in the table below are output | H |
| P0A799E or P1C5E19 is output and Communication malfunction of Rear motor generator control system DTCs in the table below are output | I |
| P0A799E or P1C5E19 is output and Sensor and actuator circuit malfunction of Rear motor generator control system DTCs in the table below are output | J |
| P0A799E or P1C5E19 is output and Sensor and actuator circuit malfunction of Hybrid control system DTCs in the table below are output | K |
| P0A799E or P1C5E19 is output and System malfunction of Motor generator control system DTCs in the table below are output | L |
| P0A799E or P1C5E19 is output and System malfunction of Hybrid control system DTCs in the table below are output | M |
| P0A799E or P1C5E19 is output and System malfunction of Rear motor generator control system DTCs in the table below are output | N |
| P0A799E or P1C5E19 is output and Rear motor generator control system DTCs in the table below are output | O |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
| P1C8049 | Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure | ||
| High voltage circuit malfunction | Hybrid control system | P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open | ||
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON | ||
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Motor generator control system | P0A1C49 | Drive Motor B" Control Module Internal Electronic Failure" |
| Rear motor generator control system | P0A1C1F | Drive Motor B" Control Module Circuit Intermittent | |
| P1C2C1C | Drive Motor B" Control Module AD Converter Circuit Voltage Out of Range | ||
| P1C2C49 | Drive Motor B" Control Module AD Converter Circuit Internal Electronic Failure | ||
| Power source circuit malfunction | Rear motor generator control system | P06B31C | Drive Motor B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P262C1C | Drive Motor B" Control Module AD Converter Circuit Voltage Out of Range | ||
| Communication malfunction | Motor generator control system | P314887 | Lost Communication between Drive Motor A" and "B" Missing Message" |
| Rear motor generator control system | P314987 | Lost Communication between Drive Motor A" and "B" Missing Message | |
| Sensor and actuator circuit malfunction | Rear motor generator control system | P0A4516 | Drive Motor B" Position Sensor Circuit Voltage Below Threshold |
| P0A4521 | Drive Motor B" Position Sensor Signal Amplitude < Minimum | ||
| P0A4522 | Drive Motor B" Position Sensor Signal Amplitude > Maximum | ||
| P0A6912 | Drive Motor B" Phase V Current(High Resolution) Circuit Short to Battery | ||
| P0A6914 | Drive Motor B" Phase V Current(High Resolution) Circuit Short to Ground or Open | ||
| P0A691C | Drive Motor B" Phase V Current(High Resolution) Circuit Voltage Out of Range | ||
| P0A6C12 | Drive Motor B" Phase W Current(High Resolution) Circuit Short to Battery | ||
| P0A6C14 | Drive Motor B" Phase W Current(High Resolution) Circuit Short to Ground or Open | ||
| P0A6C1C | Drive Motor B" Phase W Current(High Resolution) Circuit Voltage Out of Range | ||
| P0BF512 | Drive Motor B" Phase V Current Sensor Circuit Short to Battery | ||
| P0BF514 | Drive Motor B" Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0BF528 | Drive Motor B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BF912 | Drive Motor B" Phase W Current Sensor Circuit Short to Battery | ||
| P0BF914 | Drive Motor B" Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0BF928 | Drive Motor B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0C5513 | Drive Motor B" Position Sensor Circuit "A" Circuit Open | ||
| P0C5516 | Drive Motor B" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C5517 | Drive Motor B" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C5F13 | Drive Motor B" Position Sensor Circuit "B" Circuit Open | ||
| P0C5F16 | Drive Motor B" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C5F17 | Drive Motor B" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0DA316 | Drive Motor B" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold | ||
| P0DA317 | Drive Motor B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold | ||
| P1CAE49 | Drive Motor B" Position Sensor Internal Electronic Failure | ||
| P1CB138 | Drive Motor B" Position Sensor REF Signal Frequency Incorrect | ||
| P33C012 | Drive Motor B" Phase V Current Sensor Sub Circuit Short to Battery | ||
| P33C014 | Drive Motor B" Phase V Current Sensor Sub Circuit Short to Ground or Open | ||
| P33C028 | Drive Motor B" Phase V Current Sensor Sub Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P33C512 | Drive Motor B" Phase W Current Sensor Sub Circuit Short to Battery | ||
| P33C514 | Drive Motor B" Phase W Current Sensor Sub Circuit Short to Ground or Open | ||
| P33C528 | Drive Motor B" Phase W Current Sensor Sub Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P33D862 | Drive Motor B" Phase V Current Sensor Signal Compare Failure | ||
| P33D962 | Drive Motor B" Phase W Current Sensor Signal Compare Failure | ||
| Hybrid control system | P0DA31C | Drive Motor B" Inverter Voltage Sensor "A" Voltage Out of Range" | |
| System malfunction | Motor generator control system | P0A7873 | Drive Motor A" Inverter Actuator Stuck Closed" |
| P0A789E | Drive Motor A" Inverter Stuck On" | ||
| P0A7A73 | Generator Inverter Actuator Stuck Closed | ||
| P0A7A9E | Generator Inverter Stuck On | ||
| P0A949E | DC/DC Converter Stuck On | ||
| P0C7917 | Drive Motor A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold" | ||
| P0D3319 | DC/DC Converter Circuit Current Above Threshold | ||
| P0E5717 | DC/DC Converter Voltage Sensor A"(VL) Circuit Voltage Above Threshold" | ||
| P1C5D19 | Drive Motor A" Inverter Circuit Current Above Threshold" | ||
| P1C5F19 | Generator Inverter Circuit Current Above Threshold | ||
| P1CB59E | DC/DC Converter Voltage Sensor A"(VL) Stuck On" | ||
| P1CB69E | Drive Motor A" Inverter Voltage Sensor(VH) Stuck On" | ||
| Hybrid control system | P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure | |
| Rear motor generator control system | P0C3100 | Drive Motor Inverter Temperature Sensor C" Circuit | |
| System | Relevant DTC | |
|---|---|---|
| Rear motor generator control system | P0A451F | Drive Motor B" Position Sensor Circuit Intermittent |
| P0A691F | Drive Motor B" Phase V Current(High Resolution) Circuit Intermittent | |
| P0A6C1F | Drive Motor B" Phase W Current(High Resolution) Circuit Intermittent | |
| P0C551F | Drive Motor B" Position Sensor Circuit "A" Circuit Intermittent | |
| P0C5F1F | Drive Motor B" Position Sensor Circuit "B" Circuit Intermittent | |
| P0DA31F | Drive Motor B" Inverter Voltage Sensor "A" Circuit Intermittent | |
| P1C611F | Drive Motor B" Control Module Position Sensor REF Power Source Circuit Intermittent | |
| P1C631F | Drive Motor B" Control Module Offset Power Circuit Intermittent | |
| P1C661F | Drive Motor B" Control Module Circuit Intermittent | |
| P31491F | Lost Communication between Drive Motor A" and "B" Circuit Intermittent | |
| P31E41F | Drive Motor "B" Phase V Current Sensor Circuit Intermittent | |
| P31E51F | Drive Motor "B" Phase W Current Sensor Circuit Intermittent | |
P0A799E or P1C5E19 may be output as a result of the malfunctions indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
If P0A799E is output, replace the rear hybrid motor control inverter assembly after completing repairs.
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
D
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
E
F
G
H
I
J
K
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
L
M
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
N
O
Use the GTS, confirm the output DTCs.
| Result | Proceed to |
|---|---|
| P0A799E is output | A |
| P1C5E19 is output | B |
A
B
Pre-procedure1
None.
Procedure1
Read the freeze frame data of DTC P0A799E.
| Tester Display |
|---|
| Rear Motor Inverter Temperature |
| Result | Proceed to |
|---|---|
| The value of Rear Motor Inverter Temperature is 96 °C or more | A |
| The value of Rear Motor Inverter Temperature is less than 96 °C | B |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Cooling System
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>P0A4516
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Motor Resolver Circuit
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None.
Procedure1
Read the freeze frame data of DTC P1C5E19.
| Tester Display |
|---|
| Rear Motor Inverter Temperature |
| Result | Proceed to |
|---|---|
| The value of Rear Motor Inverter Temperature is 96 °C or more | A |
| The value of Rear Motor Inverter Temperature is less than 96 °C | B |
Post-procedure1
Turn the ignition switch off.
A
B