Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › REAR MOTOR GENERATOR CONTROL SYSTEM
RM3700E _51 Engine / Hybrid System _093506 HYBRID / BATTERY CONTROL _0442914 REAR MOTOR GENERATOR CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  REAR MOTOR GENERATOR CONTROL SYSTEM  P0C021D  Drive Motor "B" System Circuit Current Out of Range  


DTC SUMMARY

MALFUNCTION DESCRIPTION


This DTC is stored when the rear motor generator control system is malfunctioning and current does not flow as commanded. The cause of this malfunction may be one of the following:

Area Main Malfunction Description
Inside of rear hybrid motor control inverter assembly Rear hybrid motor control inverter assembly internal circuit malfunction
Rear traction motor assembly
·

Motor (MGR) internal malfunction (entry of foreign matter, etc.)

·

Open or short circuit in the motor coils


Inverter low-voltage circuit The connectors are not connected properly
Motor cable (for MGR)
·

Defective motor cable (for MGR) connection

·

Open circuit or poor insulation on motor cable (for MGR)


Hybrid vehicle control ECU Hybrid vehicle control ECU internal circuit malfunction


DESCRIPTION

For a description of the inverter.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>P0DA316

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate DTC Output from Priority
P0C021D Drive Motor "B" System Circuit Current Out of Range Rear motor system malfunction:
Malfunction is detected when the vehicle is stopped or being driven at low speeds. Malfunction is detected when the vehicle is stopped or being driven at low speeds.
(1 trip detection logic)
·

Wire harness or connector

·

Rear hybrid motor control inverter assembly

·

Hybrid motor control inverter assembly

·

Rear traction motor cable

·

Rear traction motor assembly

·

Hybrid vehicle control ECU


Does not come on Master Warning:
Comes on
Rear Motor Generator A

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 2 minutes or more.

3.

Turn the ignition switch to ON and wait for 5 seconds or more.

4.

Turn the ignition switch to ON (READY) and wait for 5 seconds or more.

5.

With the vehicle stopped, begin moving with the accelerator opening angle between 20% to 50% and a speed of approximately 10 km/h (6 mph), then stop the vehicle and repeat the same procedure several times.

While doing this, check that the "Rear motor torque" value does not remain at 0 N*m continuously, but rather changes to indicate that the rear motor is operating.

HINT:

Unless rear motor torque is restricted due to DTC output, the rear motor torque will not remain at 0 N*m continuously.


6.

Enter the following menus: Powertrain / Rear Motor Generator / Utility / All Readiness.

7.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.




WIRING DIAGRAM

Refer to the wiring diagram for the Rear Motor High-voltage Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Motor High-voltage Circuit

Refer to the wiring diagram for the Shut Down Signal Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Shut Down Signal Circuit

Refer to the wiring diagram for the Rear Shut Down Signal Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Shut Down Signal Circuit

CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly.




NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART




PROCEDURE

1.CHECK DTC OUTPUT

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Powertrain > Rear Motor Generator > Trouble Codes
50001 396
Result:
Result Proceed to
Only P0C021D for Rear motor generator control system is output A
P0C021D and DTCs other than the DTCs in the table below are output B
P0C021D and Insulation malfunction of Hybrid control system DTCs in the table below are output C
P0C021D and High voltage circuit malfunction of Hybrid control system DTCs in the table below are output D
P0C021D and Microcomputer malfunction of Motor generator control system DTCs in the table below are output E
P0C021D and Microcomputer malfunction of Rear motor generator control system DTCs in the table below are output F
P0C021D and Power source circuit malfunction of Rear motor generator control system DTCs in the table below are output G
P0C021D and Sensor and actuator circuit malfunction of Rear motor generator control system DTCs in the table below are output H
P0C021D and Sensor and actuator circuit malfunction of Hybrid control system DTCs in the table below are output I
P0C021D and System malfunction of Motor generator control system DTCs in the table below are output J


Table 1
Malfunction Content System Relevant DTC
Insulation malfunction Hybrid control system P1C7C49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
P1C7D49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
P1C7E49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
P1C7F49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
P1C8049 Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure
High voltage circuit malfunction Hybrid control system P0AD911 Hybrid/EV Battery Positive Contactor Circuit Short to Ground
P0AD915 Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open
P0ADD11 Hybrid/EV Battery Negative Contactor Circuit Short to Ground
P0ADD15 Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open
P1C8449 High Voltage Power Resource Circuit Short during Ready ON

Table 2
Malfunction Content System Relevant DTC
Microcomputer malfunction Motor generator control system P0A1C49 Drive Motor B" Control Module Internal Electronic Failure"
Rear motor generator control system P0A1C1F Drive Motor B" Control Module Circuit Intermittent
P1C2C1C Drive Motor B" Control Module AD Converter Circuit Voltage Out of Range
P1C2C49 Drive Motor B" Control Module AD Converter Circuit Internal Electronic Failure
Power source circuit malfunction Rear motor generator control system P06B31C Drive Motor B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P262C1C Drive Motor B" Control Module Offset Power Circuit Voltage Out of Range
Sensor and actuator circuit malfunction Rear motor generator control system P0A4516 Drive Motor B" Position Sensor Circuit Voltage Below Threshold
P0A4521 Drive Motor B" Position Sensor Signal Amplitude < Minimum
P0A4522 Drive Motor B" Position Sensor Signal Amplitude > Maximum
P0A6912 Drive Motor B" Phase V Current(High Resolution) Circuit Short to Battery
P0A6914 Drive Motor B" Phase V Current(High Resolution) Circuit Short to Ground or Open
P0A691C Drive Motor B" Phase V Current(High Resolution) Circuit Voltage Out of Range
P0A6C12 Drive Motor B" Phase W Current(High Resolution) Circuit Short to Battery
P0A6C14 Drive Motor B" Phase W Current(High Resolution) Circuit Short to Ground or Open
P0A6C1C Drive Motor B" Phase W Current(High Resolution) Circuit Voltage Out of Range
P0BF512 Drive Motor B" Phase V Current Sensor Circuit Short to Battery
P0BF514 Drive Motor B" Phase V Current Sensor Circuit Short to Ground or Open
P0BF528 Drive Motor B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BF912 Drive Motor B" Phase W Current Sensor Circuit Short to Battery
P0BF914 Drive Motor B" Phase W Current Sensor Circuit Short to Ground or Open
P0BF928 Drive Motor B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0C5513 Drive Motor B" Position Sensor Circuit "A" Circuit Open
P0C5516 Drive Motor B" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C5517 Drive Motor B" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C5F13 Drive Motor B" Position Sensor Circuit "B" Circuit Open
P0C5F16 Drive Motor B" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5F17 Drive Motor B" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0DA316 Drive Motor B" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold
P0DA317 Drive Motor B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold
P1CAE49 Drive Motor B" Position Sensor Internal Electronic Failure
P1CB138 Drive Motor B" Position Sensor REF Signal Frequency Incorrect
P33C012 Drive Motor B" Phase V Current Sensor Sub Circuit Short to Battery
P33C014 Drive Motor B" Phase V Current Sensor Sub Circuit Short to Ground or Open
P33C028 Drive Motor B" Phase V Current Sensor Sub Signal Bias Level Out of Range / Zero Adjustment Failure
P33C512 Drive Motor B" Phase W Current Sensor Sub Circuit Short to Battery
P33C514 Drive Motor B" Phase W Current Sensor Sub Circuit Short to Ground or Open
P33C528 Drive Motor B" Phase W Current Sensor Sub Signal Bias Level Out of Range / Zero Adjustment Failure
P33D862 Drive Motor B" Phase V Current Sensor Signal Compare Failure
P33D962 Drive Motor B" Phase W Current Sensor Signal Compare Failure
Hybrid control system P0DA31C Drive Motor B" Inverter Voltage Sensor "A" Voltage Out of Range"
System malfunction Motor generator control system P0A9000 Drive Motor A" Performance"
P0A9200 Hybrid Generator Performance
P0BFF1D Drive Motor A" Circuit Current Out of Range"
P0C1900 Drive Motor A" Execution Torque Performance"
P0E7100 Generator Execution Torque Performance
P1CA51D Hybrid Generator Circuit Current Out of Range

HINT:
·

P0C021D may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





Post-procedure1

a.

Turn the ignition switch off.



A

2.CHECK DIAGNOSIS RELATED INFORMATION (MOTOR GENERATOR)

B

2.CHECK DIAGNOSIS RELATED INFORMATION (MOTOR GENERATOR)

C

D

E

F

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

G

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

H

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

I

J

2.CHECK DIAGNOSIS RELATED INFORMATION (MOTOR GENERATOR)

Pre-procedure1

a.

None.


Procedure1

a.

Read the diagnosis related information for Motor Generator.

Powertrain > Motor Generator > Utility
Tester Display
Diagnosis Related Information
50005 395 56
Result:
Result Proceed to
Diagnosis Related Information P312487 is output A
Diagnosis Related Information P312487 is not output B



Post-procedure1

a.

Turn the ignition switch off.



A

B

3.CHECK FREEZE FRAME DATA (REAR INVERTER SHUT DOWN STATUS)
3.CHECK FREEZE FRAME DATA (REAR INVERTER SHUT DOWN STATUS)

Pre-procedure1

a.

None.


Procedure1

a.

Read the freeze frame data of DTC P0C021D.

Powertrain > Rear Motor Generator > DTC(P0C021D) > Freeze Frame Data
Tester Display
Rear Inverter Shut Down Status
50040 396 67 P0C021D
Result:
Result Proceed to
The value of Rear Inverter Shut Down Status is ON A
The value of Rear Inverter Shut Down Status is OFF B



Post-procedure1

a.

Turn the ignition switch off.



A

B

4.CHECK CONNECTOR CONNECTION CONDITION (REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)
4.CHECK CONNECTOR CONNECTION CONDITION (REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>P0A4516

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

5.CHECK SHUT DOWN SIGNAL CIRCUIT

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK SHUT DOWN SIGNAL CIRCUIT

NEXT

6.CHECK REAR SHUT DOWN SIGNAL CIRCUIT
6.CHECK REAR SHUT DOWN SIGNAL CIRCUIT

NEXT

7.CHECK REAR MOTOR HIGH-VOLTAGE CIRCUIT
7.CHECK REAR MOTOR HIGH-VOLTAGE CIRCUIT

NEXT

REPLACE REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY