HYBRID / BATTERY CONTROL  REAR MOTOR GENERATOR CONTROL SYSTEM  P0C7A17  Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold  


DTC SUMMARY

MALFUNCTION DESCRIPTION


When an overvoltage malfunction has occurred in the rear motor inverter or generator inverter, the rear motor generator control ECU stores this DTC. The cause of this malfunction may be one of the following:

Area Main Malfunction Description
Resolver Open or short circuit in the rear motor resolver or generator resolver circuit
Rear traction motor assembly
·

Open or short circuit in the rear motor coils

·

Motor (MGR) internal malfunction (iron particles or damage from foreign objects)


Inverter
·

Inverter internal circuit malfunction

·

Malfunction in ECU that controls the inverter

·

Malfunction in the sensors for inverter control (current sensor, voltage sensors (VLR), etc.)


HV battery
·

Open in system main relay circuit

·

Open in EV fuse circuit

·

Open in a frame wire

·

HV battery malfunction




DESCRIPTION

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate DTC Output from Priority
P0C7A17 Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold Rear motor inverter overvoltage signal detected (Overvoltage (System)) Overvoltage is detected before boosting.
(1 trip detection logic)
·

Wire harness or connector

·

Rear traction motor cable

·

Rear traction motor assembly

·

Floor wire

·

PCU-RR fuse

·

Service plug grip

·

No. 1 traction battery device box assembly

·

Rear hybrid motor control inverter assembly

·

Hybrid battery terminal block

·

HV floor under wire

·

PCU RR relay


Does not come on Master Warning:
Comes on
Rear Motor Generator A

Related Data List
DTC No. Data List
P0C7A17
·

Emergency Shutdown Signal

·

Rear Motor Inverter Shut Down Signal



CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 2 minutes or more.

3.

Turn the ignition switch to ON and wait for 5 seconds or more.

4.

Turn the ignition switch to ON (READY) and wait for 5 seconds or more.

5.

With the vehicle stopped, begin moving with the accelerator opening angle between 20% to 50% and a speed of approximately 10 km/h (6 mph), then stop the vehicle and repeat the same procedure several times.

While doing this, check that the "Rear motor torque" value does not remain at 0 N*m continuously, but rather changes to indicate that the rear motor is operating.

HINT:

Unless rear motor torque is restricted due to DTC output, the rear motor torque will not remain at 0 N*m continuously.


6.

Enter the following menus: Powertrain / Rear Motor Generator / Utility / All Readiness.

7.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.




WIRING DIAGRAM

Refer to the wiring diagram for the Rear Motor Resolver Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Motor Resolver Circuit

Refer to the wiring diagram for the Rear Motor High-voltage Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Motor High-voltage Circuit

Refer to the wiring diagram for the Rear Inverter Low-voltage Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Rear Inverter Low-voltage Circuit

Refer to the wiring diagram for the HV Battery High-voltage Line Circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>HV Battery High-voltage Line Circuit

CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly.




NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART




PROCEDURE

1.CHECK DTC OUTPUT

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Powertrain > Rear Motor Generator > Trouble Codes
50001 396
Result:
Result Proceed to
Only P0C7A17 for Rear motor generator control system is output A
P0C7A17 and DTCs other than the DTCs in the table below are output B
P0C7A17 and Insulation malfunction of Hybrid control system DTCs in the table below are output C
P0C7A17 and System main relay or high voltage circuit malfunction of Hybrid control system DTCs in the table below are output D
P0C7A17 and Microcomputer malfunction of Motor generator control system DTCs in the table below are output E
P0C7A17 and Microcomputer malfunction of Hybrid control system DTCs in the table below are output F
P0C7A17 and Power source circuit malfunction of Motor generator control system DTCs in the table below are output G
P0C7A17 and Communication malfunction of Motor generator control system DTCs in the table below are output H
P0C7A17 and Communication malfunction of Hybrid control system DTCs in the table below are output I
P0C7A17 and Sensor and actuator circuit malfunction of Motor generator control system DTCs in the table below are output J
P0C7A17 and Sensor and actuator circuit malfunction of Hybrid control system DTCs in the table below are output K
P0C7A17 and System malfunction of Motor generator control system DTCs in the table below are output L
P0C7A17 and System malfunction of Hybrid control system DTCs in the table below are output M


Table 1
Malfunction Content System Relevant DTC
Insulation malfunction Hybrid control system P1C7C49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
P1C7D49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
P1C7E49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
P1C7F49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
P1C8049 Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure
System main relay or high voltage circuit malfunction Hybrid control system P0AD911 Hybrid/EV Battery Positive Contactor Circuit Short to Ground
P0AD915 Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open
P0ADD11 Hybrid/EV Battery Negative Contactor Circuit Short to Ground
P0ADD15 Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open
P1C8449 High Voltage Power Resource Circuit Short during Ready ON

Table 2
Malfunction Content System Relevant DTC
Microcomputer malfunction Motor generator control system P0A1A47 Generator Control Module Watchdog / Safety μC Failure
P0A1A49 Generator Control Module Internal Electronic Failure
P0A1B1F Generator Control Module Circuit Intermittent
P1C2A1C Generator A/D Converter Circuit Circuit Voltage Out of Range
P1C2A49 Generator A/D Converter Circuit Internal Electronic Failure
P1C2B1C Drive Motor A" Control Module A/D Converter Circuit Voltage Out of Range"
P1C2B49 Drive Motor A" Control Module A/D Converter Circuit Internal Electronic Failure"
P313383 Communication Error from Generator to Drive Motor A" Value of Signal Protection Calculation Incorrect"
P313386 Communication Error from Generator to Drive Motor A" Signal Invalid"
P313387 Communication Error from Generator to Drive Motor A" Missing Message"
P313483 Communication Error from Drive Motor A" to Generator Value of Signal Protection Calculation Incorrect"
P313486 Communication Error from Drive Motor A" to Generator Signal Invalid"
P313487 Communication Error from Drive Motor A" to Generator Missing Message"
Hybrid control system P0A1B49 Drive Motor A" Control Module Internal Electronic Failure"
Power source circuit malfunction Motor generator control system P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
Communication malfunction Motor generator control system P312487 Lost Communication between Drive Motor A" and HV ECU Missing Message"
Hybrid control system P312387 Lost Communication with Drive Motor Control Module A" from Hybrid/EV Control Module Missing Message"
Sensor and actuator circuit malfunction Motor generator control system P0A3F16 Drive Motor A" Position Sensor Circuit Voltage Below Threshold"
P0A3F21 Drive Motor A" Position Sensor Signal Amplitude < Minimum"
P0A3F22 Drive Motor A" Position Sensor Signal Amplitude > Maximum"
P0A4B16 Generator Position Sensor Circuit Voltage Below Threshold
P0A4B21 Generator Position Sensor Signal Amplitude < Minimum
P0A4B22 Generator Position Sensor Signal Amplitude > Maximum
P0A6012 Drive Motor A" Phase V Current(High Resolution) Circuit Short to Battery"
P0A6014 Drive Motor A" Phase V Current(High Resolution) Circuit Short to Ground or Open"
P0A601C Drive Motor A" Phase V Current(High Resolution) Circuit Voltage Out of Range"
P0A6312 Drive Motor A" Phase W Current(High Resolution) Circuit Short to Battery"
P0A6314 Drive Motor A" Phase W Current(High Resolution) Circuit Short to Ground or Open"
P0A631C Drive Motor A" Phase W Current(High Resolution) Circuit Voltage Out of Range"
P0BE512 Drive Motor A" Phase U Current Sensor Circuit Short to Battery"
P0BE514 Drive Motor A" Phase U Current Sensor Circuit Short to Ground or Open"
P0BE528 Drive Motor A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"
P0BE912 Drive Motor A" Phase V Current Sensor Circuit Short to Battery"
P0BE914 Drive Motor A" Phase V Current Sensor Circuit Short to Ground or Open"
P0BE928 Drive Motor A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"
P0BED12 Drive Motor A" Phase W Current Sensor Circuit Short to Battery"
P0BED14 Drive Motor A" Phase W Current Sensor Circuit Short to Ground or Open"
P0BED28 Drive Motor A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure"
P0BFD62 Drive Motor A" Phase U-V-W Current Sensor Signal Compare Failure"
P0C5013 Drive Motor A" Position Sensor Circuit "A" Circuit Open"
P0C5016 Drive Motor A" Position Sensor Circuit "A" Circuit Voltage Below Threshold"
P0C5017 Drive Motor A" Position Sensor Circuit "A" Circuit Voltage Above Threshold"
P0C5A13 Drive Motor A" Position Sensor Circuit "B" Circuit Open"
P0C5A16 Drive Motor A" Position Sensor Circuit "B" Circuit Voltage Below Threshold"
P0C5A17 Drive Motor A" Position Sensor Circuit "B" Circuit Voltage Above Threshold"
P0C6413 Generator Position Sensor Circuit A" Circuit Open"
P0C6416 Generator Position Sensor Circuit A" Circuit Voltage Below Threshold"
P0C6417 Generator Position Sensor Circuit A" Circuit Voltage Above Threshold"
P0C6913 Generator Position Sensor Circuit B" Circuit Open"
P0C6916 Generator Position Sensor Circuit B" Circuit Voltage Below Threshold"
P0C6917 Generator Position Sensor Circuit B" Circuit Voltage Above Threshold"
P0D2D16 Drive Motor A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold"
P0D2D17 Drive Motor A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold"
P0DFA62 Generator Phase U-V-W Current Sensor Signal Compare Failure
P0E0012 Generator Phase U Current Sensor Circuit Short to Battery
P0E0014 Generator Phase U Current Sensor Circuit Short to Ground or Open
P0E0028 Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E0412 Generator Phase V Current Sensor Circuit Short to Battery
P0E0414 Generator Phase V Current Sensor Circuit Short to Ground or Open
P0E0428 Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E0812 Generator Phase W Current Sensor Circuit Short to Battery
P0E0814 Generator Phase W Current Sensor Circuit Short to Ground or Open
P0E0828 Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0E3116 DC/DC Converter Voltage Sensor A"(VL) Circuit Voltage Below Threshold"
P0E3117 DC/DC Converter Voltage Sensor A"(VL) Circuit Voltage Above Threshold"
P0E5111 DC/DC Converter Current Sensor Circuit Short to Ground
P0E5115 DC/DC Converter Current Sensor Circuit Short to Battery or Open
P0E512A DC/DC Converter Current Sensor Signal Stuck In Range
P1CAC49 Generator Position Sensor Internal Electronic Failure
P1CAD49 Drive Motor A" Position Sensor Internal Electronic Failure"
P1CAF38 Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect
P1CB038 Drive Motor A" Position Sensor REF Signal Frequency Incorrect"
Hybrid control system P0C7600 Hybrid/EV Battery System Discharge Time Too Long
P0D2D1C Drive Motor A" Inverter Voltage Sensor Voltage Out of Range"
P0E311C Boosting Converter Voltage Sensor A" Voltage Out of Range"
System malfunction Motor generator control system P0A7873 Drive Motor A" Inverter Actuator Stuck Closed"
P0A789E Drive Motor A" Inverter Stuck On"
P0A7A73 Generator Inverter Actuator Stuck Closed
P0A7A9E Generator Inverter Stuck On
P0A9000 Drive Motor A" Performance"
P0A9200 Hybrid Generator Performance
P0A949E DC/DC Converter Stuck On
P0BFF1D Drive Motor A" Circuit Current Out of Range"
P0C1900 Drive Motor A" Execution Torque Performance"
P0C7917 Drive Motor A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold"
P0CA300 DC/DC Converter Step Up Voltage Performance
P0D3319 DC/DC Converter Circuit Current Above Threshold
P0E5717 DC/DC Converter Voltage Sensor A"(VL) Circuit Voltage Above Threshold"
P0E7100 Generator Execution Torque Performance
P1C5D19 Drive Motor A" Inverter Circuit Current Above Threshold"
P1C5F19 Generator Inverter Circuit Current Above Threshold
P1CA51D Hybrid Generator Circuit Current Out of Range
P1CB59E DC/DC Converter Voltage Sensor A"(VL) Stuck On"
P1CB69E Drive Motor A" Inverter Voltage Sensor(VH) Stuck On"
P314F1F DC/DC Converter Voltage Sensor A"(VL) Circuit Intermittent"
P31531D DC/DC Converter Current Sensor Circuit Current Out of Range
Hybrid control system P0A9300 Inverter A" Cooling System Performance"
P0AA649 Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure
P0C7396 Motor Electronics Coolant Pump A" Component Internal Failure"
P314A31 Motor Electronics Coolant Pump A" No Signal"

Table 3
System Relevant DTC
Rear motor generator control system P0C7A17 Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold

HINT:
·

P0C7A17 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





Post-procedure1

a.

Turn the ignition switch off.



A

2.CHECK DTC OUTPUT

B

2.CHECK DTC OUTPUT

C

D

E

F

G

H

I

J

K

L

M

2.CHECK DTC OUTPUT

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Powertrain > Rear Motor Generator > Trouble Codes
50001 396
Result:
Result Proceed to
Only P0C7A17 for Rear motor generator control system is output A
P0C7A17 and DTCs other than the DTCs in the table below are output B
P0C7A17 and Microcomputer malfunction of Motor generator control system DTCs in the table below are output C
P0C7A17 and Microcomputer malfunction of Rear motor generator control system DTCs in the table below are output D
P0C7A17 and Power source circuit malfunction of Rear motor generator control system DTCs in the table below are output E
P0C7A17 and Communication malfunction of Motor generator control system DTCs in the table below are output F
P0C7A17 and Communication malfunction of Rear motor generator control system DTCs in the table below are output G
P0C7A17 and Sensor and actuator circuit malfunction of Motor generator control system DTCs in the table below are output H
P0C7A17 and Sensor and actuator circuit malfunction of Hybrid control system DTCs in the table below are output I
P0C7A17 and System malfunction of Rear motor generator control system DTCs in the table below are output J
P0C7A17 and Rear motor generator control system DTCs in the table below are output K


Table 1
Malfunction Content System Relevant DTC
Microcomputer malfunction Motor generator control system P0A1C49 Drive Motor B" Control Module Internal Electronic Failure"
Rear motor generator control system P0A1C1F Drive Motor B" Control Module Circuit Intermittent
P1C2C1C Drive Motor B" Control Module AD Converter Circuit Voltage Out of Range
P1C2C49 Drive Motor B" Control Module AD Converter Circuit Internal Electronic Failure
Power source circuit malfunction Rear motor generator control system P06B31C Drive Motor B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P262C1C Drive Motor B" Control Module Offset Power Circuit Voltage Out of Range
Communication malfunction Motor generator control system P314887 Lost Communication between Drive Motor A" and "B" Missing Message"
Rear motor generator control system P314987 Lost Communication between Drive Motor A" and "B" Missing Message
Sensor and actuator circuit malfunction Motor generator control system P0A4516 Drive Motor B" Position Sensor Circuit Voltage Below Threshold
P0A4521 Drive Motor B" Position Sensor Signal Amplitude < Minimum
P0A4522 Drive Motor B" Position Sensor Signal Amplitude > Maximum
P0A6912 Drive Motor B" Phase V Current(High Resolution) Circuit Short to Battery
P0A6914 Drive Motor B" Phase V Current(High Resolution) Circuit Short to Ground or Open
P0A691C Drive Motor B" Phase V Current(High Resolution) Circuit Voltage Out of Range
P0A6C12 Drive Motor B" Phase W Current(High Resolution) Circuit Short to Battery
P0A6C14 Drive Motor B" Phase W Current(High Resolution) Circuit Short to Ground or Open
P0A6C1C Drive Motor B" Phase W Current(High Resolution) Circuit Voltage Out of Range
P0BF512 Drive Motor B" Phase V Current Sensor Circuit Short to Battery
P0BF514 Drive Motor B" Phase V Current Sensor Circuit Short to Ground or Open
P0BF528 Drive Motor B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0BF912 Drive Motor B" Phase W Current Sensor Circuit Short to Battery
P0BF914 Drive Motor B" Phase W Current Sensor Circuit Short to Ground or Open
P0BF928 Drive Motor B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P0C5513 Drive Motor B" Position Sensor Circuit "A" Circuit Open
P0C5516 Drive Motor B" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C5517 Drive Motor B" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C5F13 Drive Motor B" Position Sensor Circuit "B" Circuit Open
P0C5F16 Drive Motor B" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5F17 Drive Motor B" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P1CAE49 Drive Motor B" Position Sensor Internal Electronic Failure
P1CB138 Drive Motor B" Position Sensor REF Signal Frequency Incorrect
Hybrid control system P0DA31C Drive Motor B" Inverter Voltage Sensor "A" Voltage Out of Range"
System malfunction Rear motor generator control system P0C3100 Drive Motor Inverter Temperature Sensor C" Circuit

Table 2
System Relevant DTC
Rear motor generator control system P0A451F Drive Motor B" Position Sensor Circuit Intermittent
P0A691F Drive Motor B" Phase V Current(High Resolution) Circuit Intermittent
P0A6C1F Drive Motor B" Phase W Current(High Resolution) Circuit Intermittent
P0C551F Drive Motor B" Position Sensor Circuit "A" Circuit Intermittent
P0C5F1F Drive Motor B" Position Sensor Circuit "B" Circuit Intermittent
P0DA31F Drive Motor B" Inverter Voltage Sensor "A" Circuit Intermittent
P1C611F Drive Motor B" Control Module Position Sensor REF Power Source Circuit Intermittent
P1C631F Drive Motor B" Control Module Offset Power Circuit Intermittent
P1C661F Drive Motor B" Control Module Circuit Intermittent
P31491F Lost Communication between Drive Motor A" and "B" Circuit Intermittent

HINT:
·

P0C7A17 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





Post-procedure1

a.

Turn the ignition switch off.



A

3.CHECK DIAGNOSIS RELATED INFORMATION (MOTOR GENERATOR)

B

3.CHECK DIAGNOSIS RELATED INFORMATION (MOTOR GENERATOR)

C

D

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

E

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

F

G

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

H

I

J

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

K

GO TO DTC CHART (REAR MOTOR GENERATOR CONTROL SYSTEM)

3.CHECK DIAGNOSIS RELATED INFORMATION (MOTOR GENERATOR)

Pre-procedure1

a.

None.


Procedure1

a.

Read the diagnosis related information for Motor Generator.

Powertrain > Motor Generator > Utility
Tester Display
Diagnosis Related Information
50005 395 56
Result:
Result Proceed to
Diagnosis Related Information P312487 is output A
Diagnosis Related Information P312487 is not output B



Post-procedure1

a.

Turn the ignition switch off.



A

B

4.CHECK FREEZE FRAME DATA (REAR INVERTER SHUT DOWN STATUS)
4.CHECK FREEZE FRAME DATA (REAR INVERTER SHUT DOWN STATUS)

Pre-procedure1

a.

None.


Procedure1

a.

Read the freeze frame data of DTC P0C7A17.

Powertrain > Rear Motor Generator > DTC(P0C7A17) > Freeze Frame Data
Tester Display
Rear Inverter Shut Down Status
50040 396 67 P0C7A17
Result:
Result Proceed to
The value of Rear Inverter Shut Down Status is ON A
The value of Rear Inverter Shut Down Status is OFF B



Post-procedure1

a.

Turn the ignition switch off.



A

B

5.CHECK CONNECTOR CONNECTION CONDITION (REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)
5.CHECK CONNECTOR CONNECTION CONDITION (REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM>P0A4516

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

6.CHECK REAR MOTOR RESOLVER CIRCUIT

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK REAR MOTOR RESOLVER CIRCUIT

NEXT

7.CHECK REAR MOTOR HIGH-VOLTAGE CIRCUIT
7.CHECK REAR MOTOR HIGH-VOLTAGE CIRCUIT

NEXT

8.CHECK HV BATTERY HIGH-VOLTAGE LINE CIRCUIT
8.CHECK HV BATTERY HIGH-VOLTAGE LINE CIRCUIT

NEXT

9.CHECK REAR INVERTER LOW-VOLTAGE CIRCUIT
9.CHECK REAR INVERTER LOW-VOLTAGE CIRCUIT

NEXT

REPLACE REAR HYBRID MOTOR CONTROL INVERTER ASSEMBLY