| All functions of the air conditioning system do not operate
|
IG power source circuit
|
|
| Back-up power source circuit
|
|
| LIN communication circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow Control: No blower operation
|
Blower motor circuit
|
|
| LIN communication circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: No blower control
|
Blower motor circuit
|
|
| LIN communication circuit
|
|
| Air conditioning amplifier assembly
|
|
| Air flow control: Insufficient air flow
|
Blower motor circuit
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: No cool air comes out*4
|
Refrigerant volume
|
-
|
| Refrigerant pressure*2
|
|
| Refrigerant pressure*3
|
|
| Air conditioner pressure sensor circuit
|
|
| LIN communication circuit
|
|
| Air mix damper control servo motor circuit (upper air mix)
|
|
| Air mix damper control servo motor circuit (lower air mix)
|
|
| Evaporator temperature sensor circuit
|
|
| Ambient temperature sensor circuit
|
|
| Cooler expansion valve
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (upper air mix)
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (lower air mix)
|
|
| Air conditioning harness assembly (heater radiator unit sub-assembly)
|
|
| Air conditioning harness assembly (blower assembly)
|
|
| Compressor with pulley assembly
|
|
| Air conditioning amplifier assembly
|
|
| ECM
|
|
| Temperature control: No warm air comes out
|
LIN communication circuit
|
|
| Air mix damper control servo motor circuit (upper air mix)
|
|
| Air mix damper control servo motor circuit (lower air mix)
|
|
| Evaporator temperature sensor circuit*4
|
|
| Ambient temperature sensor circuit
|
|
| PTC heater circuit*1
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (upper air mix)
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (lower air mix)
|
|
| Air conditioning harness assembly (heater radiator unit sub-assembly)
|
|
| Air conditioning harness assembly (blower assembly)
|
|
| Air conditioning amplifier assembly
|
|
| ECM
|
|
| Temperature control: Output air is warmer or cooler than the set temperature or response is slow
|
Refrigerant volume
|
-
|
| Refrigerant pressure*2
|
|
| Refrigerant pressure*3
|
|
| Ambient temperature sensor circuit
|
|
| LIN communication circuit
|
|
| Air mix damper control servo motor circuit (upper air mix)
|
|
| Air mix damper control servo motor circuit (lower air mix)
|
|
| Air inlet damper control servo motor circuit
|
|
| PTC heater circuit*1
|
|
| Heater radiator unit sub-assembly
|
|
| Cooler expansion valve*4
|
|
| Temperature control: Output air is warmer or cooler than the set temperature or response is slow
|
No. 1 air conditioning radiator damper servo sub-assembly (upper air mix)
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (lower air mix)
|
|
| No. 1 blower damper servo sub-assembly (fresh/recirculation)
|
|
| Air conditioning harness assembly (heater radiator unit sub-assembly)
|
|
| Air conditioning harness assembly (blower assembly)
|
|
| Air conditioning amplifier assembly
|
|
| ECM
|
|
| Temperature control: No temperature control (only MAX COLD or MAX HOT)
|
LIN communication circuit
|
|
| Air mix damper control servo motor circuit (upper air mix)
|
|
| Air mix damper control servo motor circuit (lower air mix)
|
|
| Ambient temperature sensor circuit
|
|
| Evaporator temperature sensor circuit*4
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (upper air mix)
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (lower air mix)
|
|
| Air conditioning harness assembly (heater radiator unit sub-assembly)
|
|
| Air conditioning harness assembly (blower assembly)
|
|
| Air conditioning amplifier assembly
|
|
| Temperature control: Output air temperature is different between left and right registers (the set temperature is the same for both)
|
Refrigerant volume
|
-
|
| Refrigerant pressure*2
|
|
| Refrigerant pressure*3
|
|
| Air mix damper control servo motor circuit (upper air mix)
|
|
| Air mix damper control servo motor circuit (lower air mix)
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (upper air mix)
|
|
| No. 1 air conditioning radiator damper servo sub-assembly (lower air mix)
|
|
| Air conditioning harness assembly (heater radiator unit sub-assembly)
|
|
| Air conditioning harness assembly (blower assembly)
|
|
| Air conditioning amplifier assembly
|
|
| No air inlet control
|
LIN communication circuit
|
|
| Air inlet damper control servo motor circuit
|
|
| No. 1 blower damper servo sub-assembly (fresh/recirculation)
|
|
| Air conditioning harness assembly (heater radiator unit sub-assembly)
|
|
| Air conditioning harness assembly (blower assembly)
|
|
| Air conditioning amplifier assembly
|
|
| Quick heater assembly does not operate*1
|
PTC heater circuit
|
|
| Air conditioning amplifier assembly
|
|
| Diagnostic trouble codes (DTCs) are not recorded. Set mode is cleared when the ignition switch is turned off
|
Back-up power source circuit
|
|
| Air conditioning amplifier assembly
|
|