2006-2011 Camry Aurion · Service Manual HEATER & AIR CONDITIONING SYSTEM

PROBLEM SYMPTOMS TABLE

Troubleshooting · Vehicles built from Jun 2009

Versions by build date: Jun 2006 – Sep 2006 Oct 2006 – May 2009 from Jun 2009

Manual A/C: 
Symptom
Suspected Area
See page
All functions of the A/C system do not operate
1. IG power source circuit
Click here
2. Back-up power source circuit
Click here
3. Heater control panel power source circuit
Click here
4. LIN communication circuit
Click here
5. A/C control assembly
Click here
6. A/C amplifier (for 2GR-FE RHD)
Click here
7. A/C amplifier (except 2GR-FE RHD)
Click here
Air Flow Control: No blower operation
1. Blower motor circuit
Click here
2. Heater control panel power source circuit
Click here
3. LIN communication circuit
Click here
4. A/C control assembly
Click here
5. A/C amplifier (for 2GR-FE RHD)
Click here
6. A/C amplifier (except 2GR-FE RHD)
Click here
Air Flow Control: No blower control
1. Blower motor circuit
Click here
2. Heater control panel power source circuit
Click here
3. LIN communication circuit
Click here
4. A/C control assembly
Click here
5. A/C amplifier (for 2GR-FE RHD)
Click here
6. A/C amplifier (except 2GR-FE RHD)
Click here
Air Flow Control: Insufficient air flow
1. Blower motor circuit
Click here
2. A/C amplifier (for 2GR-FE RHD)
Click here
3. A/C amplifier (except 2GR-FE RHD)
Click here
Temperature Control: No cool air comes out
1. Refrigerant volume
Click here
2. Refrigerant pressure
Click here
3. Pressure switch circuit
Click here
4. Air conditioning compressor magnetic clutch circuit (for 2GR-FE)
Click here
5. Compressor lock sensor circuit (for 2GR-FE)
Click here
6. Compressor solenoid circuit
Click here
7. Air mix control servo motor circuit
Click here
8. Evaporator temperature sensor circuit
Click here
9. Ambient temperature sensor circuit
Click here
10. Heater control panel power source circuit
Click here
11. LIN communication circuit
Click here
12. Expansion valve (for 2GR-FE RHD)
Click here
13. Expansion valve (except 2GR-FE RHD)
Click here
14. A/C control assembly
Click here
15. A/C amplifier (ror 2GR-FE RHD)
Click here
16. A/C amplifier (except 2GR-FE RHD)
Click here
17. ECM (for 2AZ-FE)
Click here
18. ECM (for 2GR-FE)
Click here
Temperature Control: No warm air comes out
1. Air mix control servo motor circuit
Click here
2. Evaporator temperature sensor circuit
Click here
3. Ambient temperature sensor circuit
Click here
4. A/C amplifier (for 2GR-FE RHD)
Click here
5. A/C amplifier (except 2GR-FE RHD)
Click here
Temperature Control: Output air is warmer or cooler than the set temperature or response is slow.
1. Refrigerant volume
Click here
2. Refrigerant pressure
Click here
3. Ambient temperature sensor circuit
Click here
4. Air mix control servo motor circuit
Click here
5. Radiator unit sub-assembly (for 2GR-FE RHD)
Click here
6. Radiator unit sub-assembly (except 2GR-FE RHD)
Click here
7. Expansion valve (for 2GR-FE RHD)
Click here
8. Expansion valve (except 2GR-FE RHD)
Click here
9. A/C amplifier (for 2GR-FE RHD)
Click here
10. A/C amplifier (except 2GR-FE RHD)
Click here
Temperature control: No temperature control (only Max. cool or Max. warm)
1. Air mix control servo motor circuit
Click here
2. Ambient temperature sensor circuit
Click here
3. Evaporator temperature sensor circuit
Click here
4. A/C control assembly
Click here
5. A/C amplifier (for 2GR-FE RHD)
Click here
6. A/C amplifier (except 2GR-FE RHD)
Click here
No air inlet control
1. Air inlet control servo motor circuit
Click here
2. A/C amplifier (for 2GR-FE RHD)
Click here
3. A/C amplifier (except 2GR-FE RHD)
Click here
No air flow mode control
1. Air outlet control servo motor circuit
Click here
2. A/C amplifier (for 2GR-FE RHD)
Click here
3. A/C amplifier (except 2GR-FE RHD)
Click here
Engine idle up does not occur, or is continuous
1. Air conditioning compressor magnetic clutch circuit (for 2GR-FE)
Click here
2. Compressor lock sensor circuit (for 2GR-FE)
Click here
3. Compressor solenoid circuit
Click here
4. Heater control panel power source circuit
Click here
5. LIN communication circuit
Click here
6. A/C control assembly
Click here
7. A/C amplifier (for 2GR-FE RHD)
Click here
8. A/C amplifier (except 2GR-FE RHD)
Click here
9. ECM (for 2AZ-FE)
Click here
10. ECM (for 2GR-FE)
Click here
Diagnostic trouble codes are not recorded. Set mode is cleared when ignition switch is turned off.
1. Back-up power source circuit
Click here
2. A/C amplifier (for 2GR-FE RHD)
Click here
3. A/C amplifier (except 2GR-FE RHD)
Click here
Automatic A/C: 
Symptom
Suspected Area
See page
All functions of the A/C system do not operate
1. IG power source circuit
Click here
2. Back-up power source circuit
Click here
3. Heater control panel power source circuit
Click here
4. LIN communication circuit
Click here
5. A/C control assembly
Click here
6. A/C amplifier (for 2GR-FE RHD)
Click here
7. A/C amplifier (except 2GR-FE RHD)
Click here
Air Flow Control: No blower operation
1. Blower motor circuit
Click here
2. Heater control panel power source circuit
Click here
3. LIN communication circuit
Click here
4. A/C control assembly
Click here
5. A/C amplifier (for 2GR-FE RHD)
Click here
6. A/C amplifier (except 2GR-FE RHD)
Click here
Air Flow Control: No blower control
1. Blower motor circuit
Click here
2. Heater control panel power source circuit
Click here
3. LIN communication circuit
Click here
4. A/C control assembly
Click here
5. A/C amplifier (for 2GR-FE RHD)
Click here
6. A/C amplifier (except 2GR-FE RHD)
Click here
Air Flow Control: Insufficient air flow
1. Blower motor circuit
Click here
2. A/C amplifier (for 2GR-FE RHD)
Click here
3. A/C amplifier (except 2GR-FE RHD)
Click here
Temperature Control: No cool air comes out
1. Refrigerant volume
Click here
2. Refrigerant pressure
Click here
3. Pressure switch circuit
Click here
4. Air conditioning compressor magnetic clutch circuit (for 2GR-FE)
Click here
5. Compressor lock sensor circuit (for 2GR-FE)
Click here
6. Compressor solenoid circuit
Click here
7. Air mix control servo motor circuit (Driver side)
Click here
8. Air mix control servo motor circuit (Passenger side)
Click here
9. Evaporator temperature sensor circuit
Click here
10. Room temperature sensor circuit
Click here
11. Ambient temperature sensor circuit
Click here
12. Heater control panel power source circuit
Click here
13. LIN communication circuit
Click here
14. Expansion valve (for 2GR-FE RHD)
Click here
15. Expansion valve (except 2GR-FE RHD)
Click here
16. A/C control assembly
Click here
17. A/C amplifier (for 2GR-FE RHD)
Click here
18. A/C amplifier (except 2GR-FE RHD)
Click here
19. ECM (for 2AZ-FE)
Click here
20. ECM (for 2GR-FE)
Click here
Temperature Control: No warm air comes out
1. Air mix control servo motor circuit (Driver side)
Click here
2. Air mix control servo motor circuit (Passenger side)
Click here
3. Evaporator temperature sensor circuit
Click here
4. Room temperature sensor circuit
Click here
5. Ambient temperature sensor circuit
Click here
6. A/C amplifier (for 2GR-FE RHD)
Click here
7. A/C amplifier (except 2GR-FE RHD)
Click here
Temperature Control: Output air is warmer or cooler than the set temperature or response is slow.
1. Refrigerant volume
Click here
2. Refrigerant pressure
Click here
3. Solar sensor circuit (Driver side)
Click here
4. Solar sensor circuit (Passenger side)
Click here
5. Room temperature sensor circuit
Click here
6. Ambient temperature sensor circuit
Click here
7. Air mix control servo motor circuit (Driver side)
Click here
8. Air mix control servo motor circuit (Passenger side)
Click here
9. Radiator unit sub-assembly (for 2GR-FE RHD)
Click here
10. Radiator unit sub-assembly (except 2GR-FE RHD)
Click here
11. Expansion valve (for 2GR-FE RHD)
Click here
12. Expansion valve (except 2GR-FE RHD)
Click here
13. A/C amplifier (for 2GR-FE RHD)
Click here
14. A/C amplifier (except 2GR-FE RHD)
Click here
Temperature control: No temperature control (only Max. cool or Max. warm)
1. Air mix control servo motor circuit (Driver side)
Click here
2. Air mix control servo motor circuit (Passenger side)
Click here
3. Room temperature sensor circuit
Click here
4. Ambient temperature sensor circuit
Click here
5. Evaporator temperature sensor circuit
Click here
6. Solar sensor circuit (Driver side)
Click here
7. Solar sensor circuit (Passenger side)
Click here
8. A/C control assembly
Click here
9. A/C amplifier (for 2GR-FE RHD)
Click here
10. A/C amplifier (except 2GR-FE RHD)
Click here
No air inlet control
1. Air inlet control servo motor circuit
Click here
2. A/C amplifier (for 2GR-FE RHD)
Click here
3. A/C amplifier (except 2GR-FE RHD)
Click here
No air flow mode control
1. Air outlet control servo motor circuit
Click here
2. A/C amplifier (for 2GR-FE RHD)
Click here
3. A/C amplifier (except 2GR-FE RHD)
Click here
Engine idle up does not occur, or is continuous
1. Air conditioning compressor magnetic clutch circuit (for 2GR-FE)
Click here
2. Compressor lock sensor circuit (for 2GR-FE)
Click here
3. Compressor solenoid circuit
Click here
4. Heater control panel power source circuit
Click here
5. LIN communication circuit
Click here
6. A/C control assembly
Click here
7. A/C amplifier (for 2GR-FE RHD)
Click here
8. A/C amplifier (except 2GR-FE RHD)
Click here
9. ECM (for 2AZ-FE)
Click here
10. ECM (for 2GR-FE)
Click here
Blinking of A/C indicator
1. Compressor solenoid circuit
Click here
2. A/C amplifier (for 2GR-FE RHD)
Click here
3. A/C amplifier (except 2GR-FE RHD)
Click here
Diagnostic trouble codes are not recorded. Set mode is cleared when ignition switch is turned off.
1. Back-up power source circuit
Click here
2. A/C amplifier (for 2GR-FE RHD)
Click here
3. A/C amplifier (except 2GR-FE RHD)
Click here
← PROBLEM SYMPTOMS TABLE (Oct 2006 – May 2009)TERMINALS OF ECU (Jun 2006 – Sep 2006) →