While the engine is being cranked, current flows from terminal ST2 of the ignition switch assembly*1 or terminal STAR of the certification ECU (smart key ECU assembly)*2 to the park/neutral position switch*3 or clutch start switch*4 and to terminal STA of the ECM (STA signal).
*1: w/o Entry and Start System
*2: w/ Entry and Start System
*3: for A/T
*4: for M/T
Refer to DTC P0617 (See page Engine / Hybrid System>1GR-FE (ENGINE CONTROL)>SFI SYSTEM>P0617).
| Result | Proceed to |
|---|---|
| w/o Entry and Start System | A |
| w/ Entry and Start System | B |
A
B
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Read values.
Check the result when the ignition switch is turned to ON and when the engine is started.
| Condition | Display (Starter Signal) |
|---|---|
| Ignition switch ON | OFF |
| Engine is started | ON |
OK
NG
Inspect the starter relay (ST) (See page Engine / Hybrid System>1GR-FE (STARTING)>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Disconnect the clutch start switch.
Remove the ST relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| ST relay (2) - A49-2 | Always | Below 1 Ω |
| ST relay (2) or A49-2 - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| ST relay (2) - e1-2 | Always | Below 1 Ω |
| ST relay (2) or e1-2 - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the ST relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| ST relay (1) - ST relay (5) | Always | 11 to 14 V |
| *1 | Engine Room Relay Block Assembly |
| *2 | ST Relay |
OK
NG
Inspect the starter (See page Engine / Hybrid System>1GR-FE (STARTING)>STARTER>INSPECTION).
OK
NG
Inspect the clutch start switch (for LHD) (See page Drivetrain>CLUTCH>CLUTCH PEDAL SWITCH(for LHD)>INSPECTION).
Inspect the clutch start switch (for RHD) (See page Drivetrain>CLUTCH>CLUTCH PEDAL SWITCH(for RHD)>INSPECTION).
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
A
B
C
Disconnect the clutch start switch connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A49-2 - A38-46 (STA) | Always | Below 1 Ω |
| A49-2 or A38-46 (STA) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| e1-2 - A52-46 (STA) | Always | Below 1 Ω |
| e1-2 or A52-46 (STA) - Body ground | Always | 10 kΩ or higher |
OK
NG
Inspect the ignition switch assembly (See page Engine / Hybrid System>1GR-FE (STARTING)>IGNITION SWITCH>INSPECTION).
OK
NG
Disconnect the clutch start switch connector.
Disconnect the ignition switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A49-1 - E93-7 (ST2) | Always | Below 1 Ω |
| A49-1 or E93-7 (ST2) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| e1-1 - E93-7 (ST2) | Always | Below 1 Ω |
| e1-1 or E93-7 (ST2) - Body ground | Always | 10 kΩ or higher |
OK
NG
Inspect the park/neutral position switch assembly (See page Drivetrain>A750F (AUTOMATIC TRANSMISSION / TRANSAXLE)>PARK / NEUTRAL POSITION SWITCH>INSPECTION).
OK
NG
(See pageDrivetrain>A750F (AUTOMATIC TRANSMISSION / TRANSAXLE)>PARK / NEUTRAL POSITION SWITCH>REMOVAL)
Disconnect the park/neutral position switch connector.
Disconnect the clutch start switch connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C24-5 (L) - A38-46 (STA) | Always | Below 1 Ω |
| C24-5 (L) or A38-46 (STA) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A49-2 - A38-46 (STA) | Always | Below 1 Ω |
| A49-2 or A38-46 (STA) - Body ground | Always | 10 kΩ or higher |
OK