Refer to DTC P0412 (See page Engine / Hybrid System>3UR-FE (ENGINE CONTROL)>SFI SYSTEM(w/ Secondary Air Injection System)>P0412).
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2440
P2442 |
The pressure sensor detects pulsation of the exhaust gas despite the ECM commanding the Air Switching Valve (ASV) to close, while the engine is running (1 trip detection logic). | ·
ASV ·
Open or short in ASV circuit ·
Pressure sensor ·
Pressure sensor circuit ·
Air Injection Control Driver (AID) ·
ECM |
| P2441
P2443 |
The pressure sensor detects no pulsation of the exhaust gas despite the ECM commanding the Air Switching Valve (ASV) to open, while the engine is running (2 trip detection logic). | ·
ASV ·
Open or short in ASV circuit ·
Vacuum hose (ASV - pressure sensor) ·
Air injection hose ·
Pressure sensor ·
Pressure sensor circuit ·
Air Injection Control Driver (AID) ·
ECM |
Air switching valve normal operation:
When the Air Switching Valve (ASV) is open, exhaust gas pulsation occurs in the secondary air passage.
When the ASV is closed, exhaust gas pulsation does not occur in the secondary air passage.
The ECM monitors the pressure in the secondary air passage using the pressure sensor connected to the ASV of the Secondary Air Injection (AIR) system.
If either of the following conditions occurs, the ECM interprets it as a malfunction of the AIR system, illuminates the MIL and stores DTC(s):
Exhaust gas pulsation is detected by the pressure sensor despite the ECM commanding the ASV to close.
Exhaust gas pulsation is not detected by the pressure sensor despite the ECM commanding the ASV to open.
Refer to DTC P0412 (See page Engine / Hybrid System>3UR-FE (ENGINE CONTROL)>SFI SYSTEM(w/ Secondary Air Injection System)>P0412).
Determination by ECM monitoring:
The ECM locates malfunctions in the Secondary Air Injection (AIR) system by detecting the pressure in the AIR passage between the air pump and Air Switching Valve (ASV) and stores DTC(s). Soon after a cold engine start, the monitor runs for a short time while the AIR system is both ON and OFF. The ECM detects both the pressure and the exhaust pulsation and compares them.
The following 8 patterns are AIR system pressure conditions in the AIR system passage.
| Air Pump | ON |
| Air Switching Valve | Open |
| Pressure | 2.4 kPa or higher |
| Pulsation Detection | Exhaust gas pulsation detected |
| Air Pump | OFF |
| Air Switching Valve | Open |
| Pressure | Below 2.4 kPa |
| Pulsation Detection | Exhaust gas pulsation detected |
| Air Pump | ON |
| Air Switching Valve | Closed |
| Pressure | 2.4 kPa or higher |
| Pulsation Detection | Exhaust gas pulsation not detected |
| Air Pump | OFF |
| Air Switching Valve | Close |
| Pressure | Below 2.4 kPa |
| Pulsation Detection | Exhaust gas pulsation not detected |
| Air Pump | ON |
| Air Switching Valve | Open |
| Pressure | 2.4 kPa or higher |
| Pulsation Detection | Exhaust gas pulsation detected |
| Air Pump | OFF |
| Air Switching Valve | Open |
| Pressure | Below 2.4 kPa |
| Pulsation Detection | Exhaust gas pulsation detected |
| Air Pump | ON |
| Air Switching Valve | Closed |
| Pressure | 2.4 kPa or higher |
| Pulsation Detection | Exhaust gas pulsation not detected |
| Air Pump | OFF |
| Air Switching Valve | Close |
| Pressure | Below 2.4 kPa |
| Pulsation Detection | Exhaust gas pulsation not detected |
If the detected pressure is high, the air pump is assumed to be ON and if it alternates sharply, the ASV is assumed to be open. The ECM locates malfunctions from the combination of pressures detected when the AIR system is ON and OFF.
The exhaust pulsation value is calculated in the ECM. If the calculated value exceeds a certain level, the ECM determines that the exhaust pulsation is in the AIR system.
In case 3 and 7, as the pressure sensor detects a slight pump operation pulsation, the detected value is not constant. Since the pump outlet is blocked by closing the ASV, the average pressure is higher than in case 1 (approximately 20 to 30 kPa).
In case 1, the average pressure is approximately 3 to 11 kPa. The value of 2.4 kPa indicated in the table above is a threshold for detecting pump malfunctions.
| Detected Conditions while AIR Operating:
Air Pump ON, ASV Open |
Detected Conditions while AIR not Operating:
Air Pump OFF, ASV Closed |
ECM Determination | DTCs Output |
|---|---|---|---|
| Case 1 | Case 8 | Normal | - |
| Case 1 | Case 6 | ASV stuck open | P2440
or P2442 |
| Case 1 | Case 7 | Air pump stuck ON | P2444
or P2446 |
| Case 2 | Case 8 | Air pump stuck OFF | P2445
or P2447 |
| Case 3 | Case 8 | ASV stuck closed | P2441
or P2443 |
| Case 1 | Case 5 | ASV stuck open and air pump stuck ON | P2440 and P2444
or P2442 and P2446 |
| Case 2 | Case 6 | ASV stuck open and air pump stuck OFF | P2440 and P2445
or P2442 and P2447 |
| Case 3 | Case 7 | ASV stuck closed and air pump stuck ON | P2441 and P2444
or P2443 and P2446 |
| Case 4 | Case 8 | ASV stuck closed and air pump stuck OFF | P2441 and P2445
or P2443 and P2447 |
If the vacuum hose between the ASV and the pressure sensor is not connected correctly, case 4 may occur.
By using the GTS to perform the Secondary Air Injection Check operation in the System Check, the air-fuel ratio and the pressure in the secondary air injection system passage can be checked while the secondary air injection system is operating. This helps technicians to troubleshoot the system when it malfunctions. Furthermore, Pending Codes also can be checked by performing Utility / Secondary Air Injection Check / Automatic Mode after the repair.
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
System Check:
The pressure in the secondary air passage can be checked using the GTS.
Start the engine and warm it up.
Turn the engine switch off.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV1: OPEN, AIR PUMP 2: ON, ASV2: OPEN and AIR PUMP 1: OFF, ASV1 CLOSE, AIR PUMP 2: OFF, ASV2 CLOSE.
When Manual Mode is selected, the GTS initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.
Start the engine.
Perform the AIR system intrusive operation while the engine is idling.
Check that the status of the air pump (AIR PUMP), ASV and pressure in the AIR system passage (PRESSURE) displayed on the GTS indicate the conditions shown in the table below.
| Operations | AIR PUMP | ASV | PRESSURE*1 | PULSATION*2 |
|---|---|---|---|---|
| AIR PUMP: ON, ASV: OPEN | ON | OPEN | 2.4 kPa or higher | 20 kPa or higher |
| AIR PUMP: OFF, ASV: CLOSE | OFF | CLOSE | Below 2.4 kPa | Below 30 kPa |
*1:
Average pumping pressure (gauge pressure). The pressure should be 2.4 kPa or higher when the AIR system operates.
*2:
The cumulative exhaust pulsation calculated by the ECM. If the calculated value exceeds a certain level, the ECM determines that the exhaust pulsation is in the AIR system.
Turn the engine switch off.
This Secondary Air Injection Check only allows technicians to operate the AIR system for a maximum of 5 seconds.
Furthermore, the check can only be performed up to 4 times per trip. If the test is repeated, intervals of at least 30 seconds are required between checks.
While AIR system operation using the GTS is prohibited, the GTS display indicates the prohibition (WAIT or ERROR).
If an ERROR is displayed on the GTS during the test, stop the engine for 10 minutes, and then try again.
Performing the Secondary Air Injection Check repeatedly may cause damage to the AIR system. If necessary, leave an interval of several minutes between System Check operations to prevent the system from overheating.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the engine switch turned on (IG) or the engine running.
Turn the engine switch off when the Secondary Air Injection Check operation finishes.
Bank 1 refers to the bank that includes the No. 1 cylinder*.
*: The No. 1 cylinder is the cylinder which is farthest from the transmission.
Bank 2 refers to the bank that does not include the No. 1 cylinder.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read DTCs.
| Result | Proceed to |
|---|---|
| P2440, P2441, P2442 and/or P2443 are output | A |
| P2440, P2441, P2442 and/or P2443 and P0412 and/or P0415 are output | B |
| P2440, P2441, P2442 and/or P2443 and other DTCs (except P0412 and P0415) are output | C |
If any DTCs other than P0412, P0415, P2440, P2441, P2442 and/or P2443 are output, troubleshoot those DTCs first.
A
B
(See pageEngine / Hybrid System>3UR-FE (ENGINE CONTROL)>SFI SYSTEM(w/ Secondary Air Injection System)>P0412)
C
Inspect the air pump assembly.
OK
NG
Visual check
Start the engine and warm it up.
Turn the engine switch off.
Disconnect the No. 1 air hose.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV1: OPEN, AIR PUMP 2: ON, ASV2: OPEN.
When Manual Mode is selected, the GTS initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AP and ASV operation can be selected.
Start the engine.
Perform the AIR system intrusive operation while the engine is idling.
Place your hand near the air switching valve port and check that the exhaust gas pressure pulsates when the ASV is turned on.
To avoid the danger of being burned by the exhaust gas, bring your hand close to the valve port slowly.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV1: OPEN, AIR PUMP 2: ON, ASV2: OPEN and AIR PUMP 1: ON, ASV1: CLOSE, AIR PUMP 2: ON, ASV2: CLOSE.
Check that the exhaust gas does not pulsate when the ASV is turned off.
Turn the engine switch off.
This Secondary Air Injection Check only allows technicians to operate the AIR system for a maximum of 5 seconds. Furthermore, the check can only be performed up to 4 times per trip. If the test is repeated, intervals of at least 30 seconds are required between checks.
While AIR system operation using the GTS is prohibited, the GTS display indicates the prohibition (WAIT or ERROR).
If an ERROR is displayed on the GTS during the test, stop the engine for 10 minutes, and then try again.
Performing the Secondary Air Injection Check repeatedly may cause damage to the AIR system. If necessary, leave an interval of several minutes between System Check operations to prevent the system from overheating.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the engine switch turned on (IG) or the engine running.
Turn the engine switch off when the Secondary Air Injection Check operation finishes.
| Air Pump Operations | ASV Operations | Exhaust Gas Pulsation |
|---|---|---|
| ON | OFF | Not detected |
| ON | ON | Detected |
Other inspection method:
The ASV operation can be confirmed by checking the cumulative pressure pulsation* provided in the System Check.
Perform System Check operation under Manual Mode.
*: The exhaust pulsation value is calculated in the ECM. If the calculated value exceeds a certain level, the ECM determines that the exhaust pulsation is in the AIR system.
Start the engine and warm it up.
Turn the engine switch off.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV1: OPEN, AIR PUMP 2: ON, ASV2: OPEN and AIR PUMP 1: OFF, ASV1: CLOSE, AIR PUMP 2: OFF, ASV2: CLOSE.
Start the engine after the GTS initialization is finished.
Perform the AIR system intrusive operation while the engine is idling.
Check that the air-fuel ratio and pressure in the secondary air injection system passage (Pulsation) displayed on the GTS indicate the conditions shown in the table below.
Turn the engine switch off.
| AIR System Operation | Pulsation Condition
(ECM Calculation) |
Air-Fuel Ratio
(Reference) |
|---|---|---|
| AIR PUMP: ON, ASV: OPEN | 20 kPa or higher | 18 or more |
| AIR PUMP: OFF, ASV: CLOSE | Below 30 kPa | Approximately 14.5
(around stoichiometric air-fuel ratio) |
Reference:
If the air pump operation is confirmed as normal (See page Engine / Hybrid System>3UR-FE (ENGINE CONTROL)>SFI SYSTEM(w/ Secondary Air Injection System)>P2444), the air-fuel ratio detected in front of three-way catalytic converter changes in response to the secondary air pumped into the exhaust port when the air pump operates.
| Result | Proceed to |
|---|---|
| NG | A |
| OK | B |
A
B
Check that the No. 2 and No. 3 air tubes are securely connected to both the exhaust manifold and the ASV.
Inspect the air tube for blockages and damage.
No blockages and damage on intake pipe.
OK
NG
Inspect the air switching valve assembly (See page Engine / Hybrid System>3UR-FE (EMISSION CONTROL)>AIR SWITCHING VALVE(w/ Secondary Air Injection System)>INSPECTION).
OK
NG
Disconnect the air injection control driver (AID) connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C174-1 (E) - Body ground | Always | Below 1 Ω |
| C176-1 (E2) - Body ground | Always | Below 1 Ω |
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C173-1 (BATT) - Body ground | Always | 11 to 14 V (near battery voltage) |
| C174-5 (+B) - Body ground | Engine switch on (IG) | 11 to 14 V (near battery voltage) |
| C175-1 (BAT2) - Body ground | Always | 11 to 14 V (near battery voltage) |
| C176-5 (+B2) - Body ground | Engine switch on (IG) | 11 to 14 V (near battery voltage) |
OK
NG
Disconnect the ECM connector.
Disconnect the AID connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C45-61 (AIRV) - C174-3 (SIV) | Always | Below 1 Ω |
| C45-60 (ARV2) - C176-3 (SIV2) | Always | Below 1 Ω |
| C45-61 (AIRV) or C174-3 (SIV) - Body ground | Always | 10 kΩ or higher |
| C45-60 (ARV2) or C176-3 (SIV2) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the AID connectors.
Connect terminals DI and SIV or DI2 and SIV2 of the wire harness connector for the AID.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV 1: OPEN or AIR PUMP 2: ON, ASV 2: OPEN.
When Manual Mode is selected, the GTS initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.
Start the engine.
Perform the AIR system forced operation while the engine is idling.
Measure the voltage between the SIV and E or SIV2 and E2 terminals of the ECM connector when the AIR system is ON and OFF.
Turn the engine switch off.
Performing Secondary Air Injection Check repeatedly may cause damage to the secondary air injection system. If it is necessary to repeat the check, leave an interval of several minutes between System Check operations to prevent the system from overheating.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the engine switch turned on (IG) or the engine running.
Turn the engine switch off when the Secondary Air Injection Check operation finishes.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C174-3 (SIV) - C174-1 (E) | AIR PUMP: ON, ASV: OPEN | 0.5 to 2 V |
| C176-3 (SIV2) - C176-1 (E2) | AIR PUMP: ON, ASV: OPEN | 0.5 to 2 V |
| C174-3 (SIV) - C174-1 (E) | AIR PUMP: OFF, ASV: CLOSE | 11 to 14 V |
| C176-3 (SIV2) - C176-1 (E2) | AIR PUMP: OFF, ASV: CLOSE | 11 to 14 V |
Connect terminals DI and SIP or DI2 and SIP2 of the wire harness connector for the AID.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Manual Mode / AIR PUMP 1: ON, ASV 1: OPEN or AIR PUMP 2: ON, ASV 2: OPEN.
When Manual Mode is selected, the GTS initialization (atmospheric pressure measurement) is performed automatically. The initialization takes 10 seconds. After the initialization, AIR PUMP and ASV operation can be selected.
Start the engine.
Perform the AIR system forced operation while the engine is idling.
Measure the voltage between the SIP and E or SIP2 and E2 terminals of the ECM connector when the AIR system is ON and OFF.
Turn the engine switch off.
Performing Secondary Air Injection Check repeatedly may cause damage to the secondary air injection system. If it is necessary to repeat the check, leave an interval of several minutes between System Check operations to prevent the system from overheating.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the engine switch turned on (IG) or the engine running.
Turn the engine switch off when the Secondary Air Injection Check operation finishes.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C174-4 (SIP) - C174-1 (E) | AIR PUMP: ON, ASV: OPEN | 0.5 to 2 V |
| C176-4 (SIP2) - C176-1 (E2) | AIR PUMP: ON, ASV: OPEN | 0.5 to 2 V |
| C174-4 (SIP) - C174-1 (E) | AIR PUMP: OFF, ASV: CLOSE | 11 to 14 V |
| C176-4 (SIP2) - C176-1 (E2) | AIR PUMP: OFF, ASV: CLOSE | 11 to 14 V |
OK
NG
Replace the air injection control driver (bank 1 or bank 2) (See page Engine / Hybrid System>3UR-FE (EMISSION CONTROL)>AIR INJECTION DRIVER (w/ Secondary Air Injection System)>REMOVAL).
NEXT
Start the engine and warm it up.
Turn the engine switch off.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Clear DTCs (if output) (See page Engine / Hybrid System>3UR-FE (ENGINE CONTROL)>SFI SYSTEM(w/ Secondary Air Injection System)>DTC CHECK / CLEAR).
Enter the following menus: Powertrain / Engine and ECT / Utility / Secondary Air Injection Check / Automatic Mode.
Start the engine after the GTS initialization is finished.
Perform the System Check operation by pressing Next.
After operating the AIR system, perform the following to confirm the AIR system pending codes: Press the Exit button.
Refer to the confirmation driving pattern.
Check pending DTCs.
Turn the engine switch off.
No pending DTC output.
When performing the Secondary Air Injection Check operation after the battery cable has been reconnected, wait for 7 minutes with the engine switch turned on (IG) or the engine running.
Turn the engine switch off when the Secondary Air Injection Check operation finishes.
OK
NG
Check the vacuum hose connections with the pressure sensor and ASV.
Inspect the vacuum hose for blockages and damage.
Vacuum hose has no blockages or damage.
OK
NG
OK
NG