| Symptom | Trouble Area |
|---|---|
|
*1: w/ Headup Display System *2: w/ Reverse Shift-linked Mirror *3: w/ Seat Position Memory System *4: w/ Navigation System |
|
| There are ECUs or sensors that display a communication stop on the bus diagnostic screen. Or, there are ECUs or sensors that store a communication stop history on the "Detail" screen. | ·
CAN main bus lines or connector ·
Central gateway ECU (network gateway ECU) ·
Main body ECU (multiplex network body ECU) ·
Headlight ECU sub-assembly LH ·
Multiplex tilt and telescopic ECU ·
Certification ECU (smart key ECU assembly) ·
Meter mirror sub-assembly*1 ·
Air conditioning amplifier assembly ·
Integration control sub-assembly*4 ·
Headlight ECU Sub-assembly RH ·
Front multiplex network door ECU LH*2 ·
Position control ECU assembly*3 ·
Front multiplex network door ECU RH*2 ·
Combination meter assembly ·
No. 5 global CAN junction connector ·
No. 8 global CAN junction connector ·
No. 9 global CAN junction connector |
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING
Before measuring the resistance of the CAN bus, turn the ignition switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) auxiliary battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
After the ignition switch is turned off, there may be a waiting time before disconnecting the negative (-) auxiliary battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Some parts must be initialized and set when replacing or removing and installing parts.
Click hereGeneral>SETUP>WHEN REPLACING OR REMOVING/INSTALLING PARTS>WORK PROCEDURE
After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.
DTC check procedure: Turn the ignition switch to ON and wait for 1 minute or more. Then operate the suspected malfunctioning system and drive the vehicle at 60 km/h (37 mph) or more for 5 minutes or more.
After the repair, perform the CAN bus check and check that all the ECUs and sensors connected to the CAN communication system are displayed as normal.
Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM
Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.
When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.
Disconnect the cable from the negative (-) auxiliary battery terminal.
| *a | Component with harness connected
(Central Gateway ECU (Network Gateway ECU)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D119)Location & Routingewd_type=routing;type=c;code=D119 Click Connector(D119)Instrument Panel>Instrument Panel Wire>Network Gateway ECUewd_type=component;type=c;code=D119;pinno=7,8 |
||
| D119-7 (CA5H) - D119-8 (CA5L) | Cable disconnected from negative (-) auxiliary battery terminal | Below 70 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Central Gateway ECU (Network Gateway ECU)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D119)Location & Routingewd_type=routing;type=c;code=D119 Click Connector(D119)Instrument Panel>Instrument Panel Wire>Network Gateway ECUewd_type=component;type=c;code=D119;pinno=7,8 |
||
| D119-7 (CA5H) - D119-8 (CA5L) | Cable disconnected from negative (-) auxiliary battery terminal | 54 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Central Gateway ECU (Network Gateway ECU)) |
| *b | Front view of DLC3 |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D119,D20)Location & Routingewd_type=routing;type=c,c;code=D119,D20 Click Connector(D119)Instrument Panel>Instrument Panel Wire>Network Gateway ECUewd_type=component;type=c;code=D119;pinno=7,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D119-7 (CA5H) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D119-8 (CA5L) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Central Gateway ECU (Network Gateway ECU)) |
| *b | Front view of DLC3 |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D119,D20)Location & Routingewd_type=routing;type=c,c;code=D119,D20 Click Connector(D119)Instrument Panel>Instrument Panel Wire>Network Gateway ECUewd_type=component;type=c;code=D119;pinno=7,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D119-7 (CA5H) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D119-8 (CA5L) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G121 No.9 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=1,7 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-1 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-7 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=3,9 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-3 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-9 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Reverse Shift-linked Mirror | A |
| w/o Reverse Shift-linked Mirror | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=2,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-2 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-8 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=5,11 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-5 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-11 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=6,12 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-6 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-12 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| for LHD with Seat Position Memory System | A |
| except LHD with Seat Position Memory System | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=4,10 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-4 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-10 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the G121 No.9 global CAN junction connector.
Disconnect the D166 No.9 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=17,7 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-17 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-7 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-13 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-3 (CANL) - D20-4 (CG) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-12 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-2 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Headup Display | A |
| w/o Headup Display | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-12 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-2 (CANL) - D20-4 (CG) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-13 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-3 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-16 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-6 (CANL) - D20-4 (CG) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-14 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-4 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=15,5 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-15 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-5 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-14 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-4 (CANL) - D20-4 (CG) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-16 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-6 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Navigation System | A |
| w/o Navigation System | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=19,9 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-19 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-9 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=20,10 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-20 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-10 (CANL) - D20-4 (CG) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=18,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-18 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-8 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the G121 No.9 global CAN junction connector.
Disconnect the G120 No.8 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=4,10 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G120-4 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G120-10 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Reverse Shift-linked Mirror | A |
| w/o Reverse Shift-linked Mirror | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=1,7 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G120-1 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G120-7 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| for RHD with Seat Position Memory System | A |
| except RHD with Seat Position Memory System | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G120-2 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G120-8 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G120-2 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G120-8 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=6,12 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G120-6 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G120-12 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D86 certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-12 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-2 (CANL) - D20-4 (CG) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-12 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-2 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D95 meter mirror sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-12 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-2 (CANL) - D20-4 (CG) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-13 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-3 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D22 multiplex tilt and telescopic ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-16 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-6 (CANL) - D20-4 (CG) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-14 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-4 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D11 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=15,5 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-15 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-5 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D81 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-14 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-4 (CANL) - D20-4 (CG) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-16 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-6 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D105 integration control sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=19,9 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-19 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-9 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D41 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=20,10 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-20 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-10 (CANL) - D20-4 (CG) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=18,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| D166-18 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| D166-8 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the E7 front multiplex network door ECU RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=1,7 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G120-1 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G120-7 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the L17 position control ECU assembly RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G120-2 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G120-8 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G122 No.11 CAN junction terminal connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=5,11 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G120-5 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G120-11 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A27 headlight ECU sub-assembly RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=6,12 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G120-6 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G120-12 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the E25 front multiplex network door ECU LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=2,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-2 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-8 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A26 headlight ECU sub-assembly LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=5,11 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-5 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-11 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D120 central gateway ECU (network gateway ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=6,12 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-6 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-12 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the L43 position control ECU assembly LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=4,10 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-4 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-10 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G121 No.9 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=1,7 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G121-1 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G121-7 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=3,9 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G121-3 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G121-9 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Reverse Shift-linked Mirror | A |
| w/o Reverse Shift-linked Mirror | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=2,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G121-2 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G121-8 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=5,11 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G121-5 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G121-11 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=6,12 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G121-6 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G121-12 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| for LHD with Seat Position Memory System | A |
| except LHD with Seat Position Memory System | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=4,10 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G121-4 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G121-10 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the G121 No.9 global CAN junction connector.
Disconnect the D166 No.5 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=17,7 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-17 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-7 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-13 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-3 (CANL) - D20-16 (BAT) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-12 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-2 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Headup Display | A |
| w/o Headup Display | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-12 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-2 (CANL) - D20-16 (BAT) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-13 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-3 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-16 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-6 (CANL) - D20-16 (BAT) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-14 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-4 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=15,5 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-15 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-5 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-14 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-4 (CANL) - D20-16 (BAT) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-16 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-6 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Navigation System | A |
| w/o Navigation System | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=19,9 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-19 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-9 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=20,10 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-20 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-10 (CANL) - D20-16 (BAT) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=18,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-18 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-8 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the G121 No.9 global CAN junction connector.
Disconnect the G120 No.8 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=4,10 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G120-4 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G120-10 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Reverse Shift-linked Mirror | A |
| w/o Reverse Shift-linked Mirror | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=1,7 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G120-1 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G120-7 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| for RHD with Seat Position Memory System | A |
| except RHD with Seat Position Memory System | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G120-2 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G120-8 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G120-2 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G120-8 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=6,12 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G120-6 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G120-12 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D86 certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-13 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-3 (CANL) - D20-16 (BAT) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-12 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-2 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D95 meter mirror sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-12 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-2 (CANL) - D20-16 (BAT) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-13 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-3 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D22 multiplex tilt and telescopic ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-16 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-6 (CANL) - D20-16 (BAT) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-14 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-4 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D11 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=15,5 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-15 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-5 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D81 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-14 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-4 (CANL) - D20-16 (BAT) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-16 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-6 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D105 integration control sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=19,9 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-19 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-9 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D41 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=20,10 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-20 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-10 (CANL) - D20-16 (BAT) | ||
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166,D20)Location & Routingewd_type=routing;type=c,c;code=D166,D20 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=18,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| D166-18 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| D166-8 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the E7 front multiplex network door ECU RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=1,7 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G120-1 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G120-7 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the L17 position control ECU assembly RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G120-2 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G120-8 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G122 No.11 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=5,11 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G120-5 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G120-11 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A27 headlight ECU sub-assembly RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=6,12 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G120-6 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G120-12 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the E25 front multiplex network door ECU LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120,D20)Location & Routingewd_type=routing;type=c,c;code=G120,D20 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G120-2 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G120-8 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A26 headlight ECU sub-assembly LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=5,11 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G121-5 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G121-11 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D120 central gateway ECU (network gateway ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=6,12 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G121-6 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G121-12 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the L43 position control ECU assembly LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=4,10 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=16 |
||
| G121-4 (CANH) - D20-16 (BAT) | Cable disconnected from negative (-) auxiliary battery terminal | 6 kΩ or higher |
| G121-10 (CANL) - D20-16 (BAT) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G121 No.9 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=1,7 |
||
| G121-1 (CANH) - G121-7 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=3,9 |
||
| G121-3 (CANH) - G121-9 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Reverse Shift-linked Mirror | A |
| w/o Reverse Shift-linked Mirror | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=2,8 |
||
| G121-2 (CANH) - G121-8 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=5,11 |
||
| G121-5 (CANH) - G121-11 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=6,12 |
||
| G121-6 (CANH) - G121-12 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| for LHD with Seat Position Memory System | A |
| except LHD with Seat Position Memory System | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=4,10 |
||
| G121-4 (CANH) - G121-10 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the G121 No.9 global CAN junction connector.
Disconnect the D166 No.5 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=17,7 |
||
| D166-17 (CANH) - D166-7 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 |
||
| D166-13 (CANH) - D166-3 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 |
||
| D166-12 (CANH) - D166-2 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Headup Display | A |
| w/o Headup Display | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 |
||
| D166-12 (CANH) - D166-2 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 |
||
| D166-13 (CANH) - D166-3 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 |
||
| D166-16 (CANH) - D166-6 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 |
||
| D166-14 (CANH) - D166-4 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=15,5 |
||
| D166-15(CANH) - D166-5(CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 |
||
| D166-14 (CANH) - D166-4 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 |
||
| D166-16 (CANH) - D166-6 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Navigation System | A |
| w/o Navigation System | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=19,9 |
||
| D166-19 (CANH) - D166-9 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=20,10 |
||
| D166-20 (CANH) - D166-10 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=18,8 |
||
| D166-18 (CANH) - D166-8 (CANL)) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the G121 No.9 global CAN junction connector.
Disconnect the G120 No.8 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=4,10 |
||
| G120-4 (CANH) - G120-10 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| w/ Reverse Shift-linked Mirror | A |
| w/o Reverse Shift-linked Mirror | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=1,7 |
||
| G120-1 (CANH) - G120-7 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for vehicle type.
| Result | Proceed to |
|---|---|
| for RHD with Seat Position Memory System | A |
| except RHD with Seat Position Memory System | B |
A
B
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 |
||
| G120-2 (CANH) - G120-8 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 |
||
| G120-2 (CANH) - G120-8 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=6,12 |
||
| G120-6 (CANH) - G120-12 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D86 certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 |
||
| D166-13 (CANH) - D166-3 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 |
||
| D166-12 (CANH) - D166-2 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D95 meter mirror sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=12,2 |
||
| D166-12 (CANH) - D166-2 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=13,3 |
||
| D166-13 (CANH) - D166-3 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D22 multiplex tilt and telescopic ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 |
||
| D166-16 (CANH) - D166-6 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 |
||
| D166-14 (CANH) - D166-4 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D11 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=15,5 |
||
| D166-15 (CANH) - D166-5 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D81 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=14,4 |
||
| D166-14 (CANH) - D166-4 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=16,6 |
||
| D166-16 (CANH) - D166-6 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D105 integration control sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=19,9 |
||
| D166-19 (CANH) - D166-9 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D41 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=20,10 |
||
| D166-20 (CANH) - D166-10 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=18,8 |
||
| D166-18 (CANH) - D166-8 (CANL)) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the E7 front multiplex network door ECU RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=1,7 |
||
| G120-1 (CANH) - G120-7 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the L17 position control ECU assembly RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 |
||
| G120-2 (CANH) - G120-8 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G122 No.11 CAN junction terminal connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=5,11 |
||
| G120-5 (CANH) - G120-11 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A27 headlight ECU sub-assembly RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=6,12 |
||
| G120-6 (CANH) - G120-12 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the E25 front multiplex network door ECU LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=2,8 |
||
| G121-2 (CANH) - G121-8 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A26 headlight ECU sub-assembly LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=5,11 |
||
| G121-5 (CANH) - G121-11 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D120 central gateway ECU (network gateway ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=6,12 |
||
| G121-6 (CANH) - G121-12 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the L43 position control ECU assembly LH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=4,10 |
||
| G121-4 (CANH) - G121-10 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D120 central gateway ECU (network gateway ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=6,12 |
||
| G121-6 (CANH) - G121-12 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G121 No.9 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121)Location & Routingewd_type=routing;type=c;code=G121 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=1,7 |
||
| G121-1 (CANH) - G121-7 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G121,D20)Location & Routingewd_type=routing;type=c,c;code=G121,D20 Click Connector(G121)Instrument Panel>Floor Wire>No. 9 Global CAN Junction Connectorewd_type=component;type=c;code=G121;pinno=3,9 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G121-3 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 200 Ω or higher |
| G121-9 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the G121 No.9 global CAN junction connector.
Disconnect the D166 No.5 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=17,7 |
||
| D166-17 (CANH) - D166-7 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=20,10 |
||
| D166-20 (CANH) - D166-10 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D166)Location & Routingewd_type=routing;type=c;code=D166 Click Connector(D166)Instrument Panel>Instrument Panel Wire>No. 5 Global CAN Junction Connectorewd_type=component;type=c;code=D166;pinno=18,8 |
||
| D166-18 (CANH) - D166-8 (CANL)) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the G121 No.9 global CAN junction connector.
Disconnect the G120 No.8 global CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=4,10 |
||
| G120-4 (CANH) - G120-10 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G120)Location & Routingewd_type=routing;type=c;code=G120 Click Connector(G120)Instrument Panel>Floor Wire>No. 8 Global CAN Junction Connectorewd_type=component;type=c;code=G120;pinno=2,8 |
||
| G120-2 (CANH) - G120-8 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the D166 No.5 global CAN junction connector.
Disconnect the D41 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D41)Location & Routingewd_type=routing;type=c;code=D41 Click Connector(D41)Instrument Panel>Instrument Panel Wire>Combination Meter Assemblyewd_type=component;type=c;code=D41;pinno=29,30 |
||
| D41-29 (CANH) - D41-30 (CANL) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Reconnect the G120 No. 8 global CAN junction connector.
Disconnect the G122 No. 11 CAN junction connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G122,D20)Location & Routingewd_type=routing;type=c,c;code=G122,D20 Click Connector(G122)Instrument Panel>Floor Wire>No. 1 CAN Junction Terminalewd_type=component;type=c;code=G122;pinno=3,2 Click Connector(D20)Instrument Panel>Instrument Panel Wire>DLC3ewd_type=component;type=c;code=D20;pinno=4 |
||
| G122-3 (CANH) - D20-4 (CG) | Cable disconnected from negative (-) auxiliary battery terminal | 108 to 132 Ω |
| G122-2 (CANL) - D20-4 (CG) | ||
| Proceed to |
|---|
| OK |
| NG |
OK
NG