Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2020.11–2021.08
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0463852 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P1A7F00  DC/DC Converter "A" Overvoltage (System Performance)  


DTC SUMMARY

MALFUNCTION DESCRIPTION


This DTC indicates that an overvoltage in the inverter has occurred. The cause of this malfunction may be one of the following:

Area Main Malfunction Description
Inverter low-voltage circuit The connectors are not connected properly
Resolver Open or short circuit in the drive motor resolver or FC air compressor motor resolver circuit
Drive motor, FC air compressor motor
·

Open or short circuit in the drive motor or FC air compressor motor coils

·

An internal drive motor or FC air compressor motor malfunction (iron particles or damage from foreign objects)


HV battery high-voltage line circuit
·

Open circuit or improper connection of "service plug or frame wire from EV supply battery assembly to inverter"

·

System main relay malfunction


FC converter assembly low-voltage circuit The connectors are not connected properly
FC converter assembly high-voltage line circuit High-voltage line circuit malfunction (From FC converter assembly to inverter with converter assembly)


DESCRIPTION

For a description of the boost converter.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0CA300

If a malfunction occurs in the boost converter, the MG ECU detects it and transmits this information to the EV control ECU.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P1A7F00 DC/DC Converter "A" Overvoltage (System Performance) Boost converter overvoltage signal detected (overvoltage due to system malfunction)*:
Overvoltage is detected before boosting.
A malfunction is detected in any of the boost converter components (inverter, FCV with motor transaxle assembly, MG ECU, etc.).
(1 trip detection logic)
·

No. 1 EV battery junction block assembly

·

Inverter with converter assembly

·

FC converter assembly

·

Service plug grip (EV fuse)

·

FCV with motor transaxle assembly

·

FC air compressor with motor assembly

·

FC junction cable

·

EV control ECU

·

IGCT NO. 4 fuse

·

Wire harness or connector


Master Warning:
Comes on
EV A

*: This DTC is output when an overvoltage in the pre-boost is detected and there is no history information indicating the specific part.

Check related parts (inverter, FC converter assembly, drive motor, FC air compressor motor, resolver, cable, wire harness, EV control ECU).

CONFIRMATION DRIVING PATTERN

HINT:

After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.]

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


1.

Perform a road test according to the freeze frame data item for approximately 10 minutes.

2.

Enter the following menus: Powertrain / EV / Utility / All Readiness.

3.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




WIRING DIAGRAM

Refer to the wiring diagram for DTC P1E8649.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P1E8649

Refer to the wiring diagram for DTC P0AA649.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA649

Refer to the wiring diagram for DTC P0A1B1F.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A1B1F

Refer to the wiring diagram for the inverter low-voltage circuit.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Inverter Low-voltage Circuit

CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.

Make sure to remove the service plug grip first.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the EV supply battery assembly

-

Disconnecting the low voltage connector of the FC converter assembly


·
A484004

To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.

-

The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.

-

Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.


·
A484005C01
1.667,0.74 2.115,0.427 true 2.188,0.385 2.448,0.552 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.

If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.

·
A484932

Since high voltage accumulates within the FC stack assembly with FC converter, never perform the work of separating the FC stack assembly with FC converter into the FC converter assembly and FC stack assembly without first performing electrical charge discharge (forced electrical charge discharge or electrical charge self-discharge), because doing so is dangerous.

Click hereEngine / Hybrid System>FC CONTROL>FC STACK>REMOVAL

·

Removing and installing the FC stack assembly without first discharging the electrical charge may result in an electric shock due to the high voltage circuit.



NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART


·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



PROCEDURE

1.CHECK DTC OUTPUT (EV)

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > EV > Trouble Codes
50001 397
Result:
Result Proceed to
P1A7F00 only is output, or DTCs except the ones in the table below are also output. A
Any of the following DTCs including pending DTCs are also output. B

Malfunction Content Relevant DTC
Insulation Malfunction P1C7C49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
P1C7D49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
P1C7E49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
P1C7F49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
P1EEC49 Hybrid/EV Battery Voltage System Isolation (FC Air Compressor Area) Internal Electronic Failure
P1EED49 Hybrid/EV Battery Voltage System Isolation (FC Area) Internal Electronic Failure
P1EEE49 Hybrid/EV Battery Voltage System Isolation (Hydrogen Pump Area) Internal Electronic Failure
P1EEF49 Hybrid/EV Battery Voltage System Isolation (FC Coolant Pump Area) Internal Electronic Failure
High Voltage Circuit Malfunction P0AD911 Hybrid/EV Battery Positive Contactor Circuit Short to Ground
P0AD915 Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open
P0ADD11 Hybrid/EV Battery Negative Contactor Circuit Short to Ground
P0ADD15 Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open
P1C8449 High Voltage Power Resource Circuit Voltage Sensor after Boosting Malfunction


HINT:

P1A7F00 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





Post-procedure1

a.

Turn the ignition switch off.



A

2.CHECK DTC OUTPUT (FCDC)

B

GO TO DTC CHART (HYBRID CONTROL SYSTEM)

2.CHECK DTC OUTPUT (FCDC)

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > FCDC > Trouble Codes
50001 493
Result:
Result Proceed to
"DTC is not output" or "DTCs other than those listed below are output" A
Outputs the following DTCs simultaneously
(includes pending DTCs)
B

Malfunction Content Relevant DTC
Power source circuit malfunction P1F651C FC Converter Control Module Power Supply (-5V) Circuit Voltage Out of Range
P1F661C FC Converter Control Module Power Supply (+V5AREF) Circuit Voltage Out of Range
Sensor and actuator circuit malfunction P1D0618 FC Converter Phase U Current Circuit Current Below Threshold
P1D0619 FC Converter Phase U Current Circuit Current Above Threshold
P1D0718 FC Converter Phase V Current Circuit Current Below Threshold
P1D0719 FC Converter Phase V Current Circuit Current Above Threshold
P1D0818 FC Converter Phase W Current Circuit Current Below Threshold
P1D0819 FC Converter Phase W Current Circuit Current Above Threshold
P1D0918 FC Converter Phase X Current Circuit Current Below Threshold
P1D0919 FC Converter Phase X Current Circuit Current Above Threshold
P1D3011 Phase U Reactor Current Sensor Circuit Short to Ground
P1D3015 Phase U Reactor Current Sensor Circuit Short to Battery or Open
P1D301C Phase U Reactor Current Sensor Circuit Voltage Out of Range
P1D3028 Phase U Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P1D3511 Phase V Reactor Current Sensor Circuit Short to Ground
P1D3515 Phase V Reactor Current Sensor Circuit Short to Battery or Open
P1D351C Phase V Reactor Current Sensor Circuit Voltage Out of Range
P1D3528 Phase V Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P1D3A11 Phase W Reactor Current Sensor Circuit Short to Ground
P1D3A15 Phase W Reactor Current Sensor Circuit Short to Battery or Open
P1D3A1C Phase W Reactor Current Sensor Circuit Voltage Out of Range
P1D3A28 Phase W Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P1D4011 Phase X Reactor Current Sensor Circuit Short to Ground
P1D4015 Phase X Reactor Current Sensor Circuit Short to Battery or Open
P1D401C Phase X Reactor Current Sensor Circuit Voltage Out of Range
P1D4028 Phase X Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
P1D4512 Phase U Temperature Sensor Circuit Short to Battery
P1D4514 Phase U Temperature Sensor Circuit Short to Ground or Open
P1D4A12 Phase V Temperature Sensor Circuit Short to Battery
P1D4A14 Phase V Temperature Sensor Circuit Short to Ground or Open
P1D4F62 Total Reactor Current/FC Current Signal Compare Failure
P1D5012 Phase W Temperature Sensor Circuit Short to Battery
P1D5014 Phase W Temperature Sensor Circuit Short to Ground or Open
P1D5512 Phase X Temperature Sensor Circuit Short to Battery
P1D5514 Phase X Temperature Sensor Circuit Short to Ground or Open
System malfunction P1DDA00 FC Converter Phase U Performance
P1DDA4B FC Converter Phase U Over Temperature
P1DDA9E FC Converter Phase U Fail Signal Stuck On
P1DDB00 FC Converter Phase V Performance
P1DDB4B FC Converter Phase V Over Temperature
P1DDB9E FC Converter Phase V Fail Signal Stuck On
P1DDC00 FC Converter Phase W Performance
P1DDC4B FC Converter Phase W Over Temperature
P1DDC9E FC Converter Phase W Fail Signal Stuck On
P1DDD00 FC Converter Phase X Performance
P1DDD4B FC Converter Phase X Over Temperature
P1DDD9E FC Converter Phase X Fail Signal Stuck On


HINT:

P1A7F00 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





Post-procedure1

a.

Turn the ignition switch off.



A

3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A001C

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

4.CHECK FC AIR COMPRESSOR RESOLVER CIRCUIT

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.CHECK FC AIR COMPRESSOR RESOLVER CIRCUIT

NEXT

5.CHECK MOTOR RESOLVER CIRCUIT
5.CHECK MOTOR RESOLVER CIRCUIT

NEXT

6.CHECK FC AIR COMPRESSOR HIGH-VOLTAGE CIRCUIT
6.CHECK FC AIR COMPRESSOR HIGH-VOLTAGE CIRCUIT

NEXT

7.CHECK MOTOR HIGH-VOLTAGE CIRCUIT
7.CHECK MOTOR HIGH-VOLTAGE CIRCUIT

NEXT

8.CHECK HV BATTERY HIGH-VOLTAGE LINE CIRCUIT
8.CHECK HV BATTERY HIGH-VOLTAGE LINE CIRCUIT

NEXT

9.CHECK INVERTER LOW-VOLTAGE CIRCUIT
9.CHECK INVERTER LOW-VOLTAGE CIRCUIT

NEXT

10.CHECK CONNECTOR CONNECTION CONDITION (FC CONVERTER ASSEMBLY LOW-VOLTAGE CONNECTOR)
10.CHECK CONNECTOR CONNECTION CONDITION (FC CONVERTER ASSEMBLY LOW-VOLTAGE CONNECTOR)

Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1D0619

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

11.CHECK FC CONVERTER ASSEMBLY (FC JUNCTION CABLE CONNECTION CONDITION)

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

11.CHECK FC CONVERTER ASSEMBLY (FC JUNCTION CABLE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



Procedure1

a.
A484671C01
0,2.438 0.313,2.635 0.313,0.198 10 true *B 0,0 0.313,0.198 0.313,0.198 10 true *A
*A for LHD
*B for RHD


Check the connector connections and contact pressure of the relevant terminals for the FC junction cable connectors.

HINT:

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING


OK:

The connectors are connected securely and there are no contact pressure problems.


Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



Post-procedure1

a.

None.



A

12.CHECK INVERTER WITH CONVERTER ASSEMBLY (FC JUNCTION CABLE CONNECTION CONDITION)

B

REPLACE MALFUNCTIONING PARTS

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

12.CHECK INVERTER WITH CONVERTER ASSEMBLY (FC JUNCTION CABLE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


Pre-procedure1

a.

Check that the service plug grip and FC converter power outlet cable are not installed.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



Procedure1

a.
A483165C01
0,0 0.313,0.198 0.313,0.198 10 true *A 0,2.458 0.313,2.656 0.313,0.198 10 true *B
*A for LHD
*B for RHD


Check the connector connections and contact pressure of the relevant terminals for the FC junction cable connectors.

HINT:

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING


OK:

The connectors are connected securely and there are no contact pressure problems.


Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



Post-procedure1

a.

None.



A

13.CHECK FC JUNCTION CABLE

B

REPLACE MALFUNCTIONING PARTS

C

REPAIR OR REPLACE HARNESS OR CONNECTOR

13.CHECK FC JUNCTION CABLE
CAUTION:

Be sure to wear insulated gloves.


Pre-procedure1

a.

Check that the service plug grip is not installed to FC stack assembly and EV battery.

NOTICE:

After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.
A483165C01
0,0 0.313,0.198 0.313,0.198 10 true *A 0,2.458 0.313,2.656 0.313,0.198 10 true *B
*A for LHD
*B for RHD


Disconnect the FC junction cable from the inverter with converter assembly.


c.
A484671C01
0,2.438 0.313,2.635 0.313,0.198 10 true *B 0,0 0.313,0.198 0.313,0.198 10 true *A
*A for LHD
*B for RHD


Disconnect the FC junction cable from the FC converter assembly.

HINT:

Make sure that no foreign matter has entered or contaminated the FC junction cable.



Procedure1

a.
C257176C52
0.438,1.031 0.833,1.344 0.396,0.313 0.969,1.719 1.26,1.188 true 2.25,1.729 1.938,1.177 true 2.635,0.625 2.375,0.771 true 2.688,0.542 3,0.698 0.313,0.156 10 false *1 0.073,0.083 0.385,0.24 0.313,0.156 10 false *a 2.26,1.75 2.573,1.906 0.313,0.156 10 false N 0.927,1.75 1.24,1.906 0.313,0.156 10 false P 0.583,1.115 0.896,1.271 0.313,0.156 10 false x1
*1 Shield Ground
*a FC Junction Cable
(Inverter with Converter Assembly Side)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(x1)Location & Routing

Click Connector(x1)Engine Compartment>FC Junction Cable>Inverter with Converter Assembly

x1-1 (P) - x1-2 (N) Ignition switch off 100 kΩ or higher


NOTICE:

Be sure not to damage or deform the terminal being inspected.


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the FC junction cable.



OK

14.REPLACE INVERTER WITH CONVERTER ASSEMBLY

NG

REPLACE FC JUNCTION CABLE

14.REPLACE INVERTER WITH CONVERTER ASSEMBLY

NEXT

15.CLEAR DTC
15.CLEAR DTC

NEXT

16.SIMULATION TEST
16.SIMULATION TEST

Pre-procedure1

a.

Turn the ignition switch to ON (READY).


b.

Perform a road test according to the freeze frame data item for approximately 10 minutes.

CAUTION:

When performing the confirmation driving pattern, obey all speed limits and traffic laws.



Procedure1

a.

Check for DTCs.

Powertrain > EV > Trouble Codes
50001 397
Result:
Result Proceed to
P1A7F00 is output A
P1A7F00 is not output B



Post-procedure1

a.

Turn the ignition switch off.



A

REPLACE FC CONVERTER ASSEMBLY

B

COMPLETED